{"title":"Effect of Abutment Cooling on Reverse Torque Values of Abutment Screws: An In Vitro Study.","authors":"Nirosa Srimurugan-Thayanithi, Samir Abou-Ayash, Burak Yilmaz, Martin Schimmel, Urs Brägger","doi":"10.11607/jomi.9499","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate the effect of cooling on the reverse torque values of different abutments in bone-level and tissue-level implants. The null hypothesis was that there would be no difference in reverse torque values of abutment screws when cooled and uncooled implant abutments were compared. <b>Materials and Methods:</b> Bone-level and tissue-level implants (Straumann, each n = 36) were placed in synthetic bone blocks and subdivided into three groups (each n = 12) based on the abutment type (titanium base, cementable abutment, abutment for screw-retained restorations). All abutment screws were tightened to 35 Ncm torque. In half of the implants, a dry ice rod was applied on the abutments close to the implant-abutment connection for 60 seconds before untightening the abutment screw. The remaining implant-abutment pairs were not cooled. The maximum reverse torque values were recorded using a digital torque meter. The tightening and untightening procedure was repeated three times for each implant including cooling for the test groups, resulting in 18 reverse torque values per group. Two-way analysis of variance (ANOVA) was used to analyze the effect of cooling and abutment type on the measurements. Post hoc <i>t</i> tests were used to make group comparisons (α = .05). The <i>P</i> values of post hoc tests were corrected for multiple testing using the Bonferroni-Holm method. <b>Results:</b> The null hypothesis was rejected. Cooling and abutment type significantly affected the reverse torque values in bone-level implants (<i>P</i> = .004) but not in tissue-level implants (<i>P</i> = .051). The reverse torque values of bone-level implants significantly decreased after cooling (20.31 ± 2.55 Ncm vs 17.61 ± 2.49 Ncm). Overall mean reverse torque values were significantly higher in bone-level implants compared to tissue-level implants (18.96 ± 2.84 Ncm vs 16.13 ± 3.17 Ncm; <i>P</i> < .001). <b>Conclusion:</b> Cooling of the implant abutment led to a significant decrease in reverse torque values in bone-level implants and may therefore be recommended as a pretreatment before the application of procedures to remove a stuck implant part.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9499","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To evaluate the effect of cooling on the reverse torque values of different abutments in bone-level and tissue-level implants. The null hypothesis was that there would be no difference in reverse torque values of abutment screws when cooled and uncooled implant abutments were compared. Materials and Methods: Bone-level and tissue-level implants (Straumann, each n = 36) were placed in synthetic bone blocks and subdivided into three groups (each n = 12) based on the abutment type (titanium base, cementable abutment, abutment for screw-retained restorations). All abutment screws were tightened to 35 Ncm torque. In half of the implants, a dry ice rod was applied on the abutments close to the implant-abutment connection for 60 seconds before untightening the abutment screw. The remaining implant-abutment pairs were not cooled. The maximum reverse torque values were recorded using a digital torque meter. The tightening and untightening procedure was repeated three times for each implant including cooling for the test groups, resulting in 18 reverse torque values per group. Two-way analysis of variance (ANOVA) was used to analyze the effect of cooling and abutment type on the measurements. Post hoc t tests were used to make group comparisons (α = .05). The P values of post hoc tests were corrected for multiple testing using the Bonferroni-Holm method. Results: The null hypothesis was rejected. Cooling and abutment type significantly affected the reverse torque values in bone-level implants (P = .004) but not in tissue-level implants (P = .051). The reverse torque values of bone-level implants significantly decreased after cooling (20.31 ± 2.55 Ncm vs 17.61 ± 2.49 Ncm). Overall mean reverse torque values were significantly higher in bone-level implants compared to tissue-level implants (18.96 ± 2.84 Ncm vs 16.13 ± 3.17 Ncm; P < .001). Conclusion: Cooling of the implant abutment led to a significant decrease in reverse torque values in bone-level implants and may therefore be recommended as a pretreatment before the application of procedures to remove a stuck implant part.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.