Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study.
Jay Rahesh Dondani, Vikrant Pardeshi, Arti Gangurde, Almas Shaikh, Aushili Mahule, Prachi Deval
{"title":"Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study.","authors":"Jay Rahesh Dondani, Vikrant Pardeshi, Arti Gangurde, Almas Shaikh, Aushili Mahule, Prachi Deval","doi":"10.11607/ijp.7798","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.</p><p><strong>Materials and methods: </strong>Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.</p><p><strong>Results: </strong>No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.</p><p><strong>Conclusion: </strong>Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"273–281"},"PeriodicalIF":2.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7798","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.
Materials and methods: Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.
Results: No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.
Conclusion: Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.