Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis.

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Annals of Thoracic and Cardiovascular Surgery Pub Date : 2023-06-20 DOI:10.5761/atcs.ra.22-00125
Giorgia Colarossi, Filippo Migliorini, Michael Becker, Jessica P Arias, Ruediger Autschbach, Ajay Moza, Ali Aljalloud
{"title":"Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis.","authors":"Giorgia Colarossi,&nbsp;Filippo Migliorini,&nbsp;Michael Becker,&nbsp;Jessica P Arias,&nbsp;Ruediger Autschbach,&nbsp;Ajay Moza,&nbsp;Ali Aljalloud","doi":"10.5761/atcs.ra.22-00125","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta- analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR).</p><p><strong>Methods: </strong>This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered.</p><p><strong>Results: </strong>The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06).</p><p><strong>Conclusion: </strong>Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation.</p>","PeriodicalId":8037,"journal":{"name":"Annals of Thoracic and Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2c/d2/atcs-29-107.PMC10284666.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5761/atcs.ra.22-00125","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta- analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR).

Methods: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered.

Results: The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06).

Conclusion: Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
传统假体与无缝线的主动脉瓣置换术:meta分析。
目的:穿刺无缝合线瓣膜已得到广泛应用。这种假体是否优于传统的缝合假体尚不清楚。这项荟萃分析比较了Perceval植入物与缝合的传统主动脉瓣置换术(AVR)。方法:本荟萃分析按照系统评价和荟萃分析指南的首选报告项目进行。访问了以下数据库:PubMed、Google Scholar、Web of Science、Scopus和EMBASE。所有比较Perceval与传统假体治疗AVR的临床研究都被考虑在内。结果:Perceval组起搏器植入率较高(P)。结论:鉴于ACC时间和CPB时间较短,Perceval AVR可作为高危患者的替代选择。珀西瓦尔术后起搏器植入率较高,可能限制其常规植入率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Thoracic and Cardiovascular Surgery
Annals of Thoracic and Cardiovascular Surgery CARDIAC & CARDIOVASCULAR SYSTEMS-SURGERY
CiteScore
2.80
自引率
0.00%
发文量
56
审稿时长
4-8 weeks
期刊介绍: Information not localized
期刊最新文献
Arterial Embolization and Cone-Beam Computed Tomography-Guided Lung Resection for Anomalous Systemic Arterial Blood Supply to Normal Lung: Two Case Reports. Surgery for Ascending Aortic Aneurysm and Aortic Valve Insufficiency in Conditions of Active Proceeding Syphilitic Aortitis and Valvulitis. Impact of Graft Velocity on Saphenous Vein Graft Atherosclerosis after Coronary Artery Bypass Grafting. Surgery for Secondary Spontaneous Pneumothorax with Chronic Lung Diseases. Impact of Impella Support on Clinical Outcomes in Patients with Postcardiotomy Cardiogenic Shock.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1