A New Strategy for Evaluating the Quality of Laboratory Results for Big Data Research: Using External Quality Assessment Survey Data (2010-2020).

IF 4 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Annals of Laboratory Medicine Pub Date : 2023-09-01 DOI:10.3343/alm.2023.43.5.425
Eun-Jung Cho, Tae-Dong Jeong, Sollip Kim, Hyung-Doo Park, Yeo-Min Yun, Sail Chun, Won-Ki Min
{"title":"A New Strategy for Evaluating the Quality of Laboratory Results for Big Data Research: Using External Quality Assessment Survey Data (2010-2020).","authors":"Eun-Jung Cho,&nbsp;Tae-Dong Jeong,&nbsp;Sollip Kim,&nbsp;Hyung-Doo Park,&nbsp;Yeo-Min Yun,&nbsp;Sail Chun,&nbsp;Won-Ki Min","doi":"10.3343/alm.2023.43.5.425","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research.</p><p><strong>Methods: </strong>We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data. Seven measurands were analyzed using commutable materials: HbA1c, creatinine (Cr), total cholesterol (TC), triglyceride (TG), alpha-fetoprotein (AFP), prostate-specific antigen (PSA), and cardiac troponin I (cTnI). These were classified into three groups based on their standardization or harmonization status. HbA1c, Cr, TC, TG, and AFP were analyzed with respect to peer group values. PSA and cTnI were analyzed in separate peer groups according to the calibrator type and manufacturer, respectively. The acceptance rate and absolute percentage bias at the medical decision level were calculated based on biological variation criteria.</p><p><strong>Results: </strong>The acceptance rate (22.5%-100%) varied greatly among the test items, and the mean percentage biases were 0.6%-5.6%, 1.0%-9.6%, and 1.6%-11.3% for all items that satisfied optimum, desirable, and minimum criteria, respectively.</p><p><strong>Conclusions: </strong>The acceptance rate of participants and their external quality assessment (EQA) results exhibited statistically significant differences according to the quality grade for each criterion. Even when they passed the EQA standards, the test results did not guarantee the quality requirements for big data. We suggest that the KEQAS classification can serve as a guide for building big data.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":"43 5","pages":"425-433"},"PeriodicalIF":4.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e4/53/alm-43-5-425.PMC10151270.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2023.43.5.425","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 2

Abstract

Background: To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research.

Methods: We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data. Seven measurands were analyzed using commutable materials: HbA1c, creatinine (Cr), total cholesterol (TC), triglyceride (TG), alpha-fetoprotein (AFP), prostate-specific antigen (PSA), and cardiac troponin I (cTnI). These were classified into three groups based on their standardization or harmonization status. HbA1c, Cr, TC, TG, and AFP were analyzed with respect to peer group values. PSA and cTnI were analyzed in separate peer groups according to the calibrator type and manufacturer, respectively. The acceptance rate and absolute percentage bias at the medical decision level were calculated based on biological variation criteria.

Results: The acceptance rate (22.5%-100%) varied greatly among the test items, and the mean percentage biases were 0.6%-5.6%, 1.0%-9.6%, and 1.6%-11.3% for all items that satisfied optimum, desirable, and minimum criteria, respectively.

Conclusions: The acceptance rate of participants and their external quality assessment (EQA) results exhibited statistically significant differences according to the quality grade for each criterion. Even when they passed the EQA standards, the test results did not guarantee the quality requirements for big data. We suggest that the KEQAS classification can serve as a guide for building big data.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
大数据研究实验室结果质量评估新策略:外部质量评估调查数据(2010-2020)。
背景:为了保证医学领域大数据研究的有效结果,输入的实验室结果需要高质量。我们的目标是建立一个评估适合大数据研究的实验室结果质量的策略。方法:我们使用韩国外部质量评估服务协会(KEQAS)的数据对多中心数据进行回顾性分析。采用可交换材料分析7项指标:HbA1c、肌酐(Cr)、总胆固醇(TC)、甘油三酯(TG)、甲胎蛋白(AFP)、前列腺特异性抗原(PSA)和心肌肌钙蛋白I (cTnI)。根据其标准化或协调状态将其分为三组。HbA1c、Cr、TC、TG、AFP相对于同组值进行分析。PSA和cTnI分别根据校准器类型和制造商在不同的同行组中进行分析。根据生物变异标准计算医疗决策水平的接受率和绝对百分比偏差。结果:各测试项目的合格率(22.5% ~ 100%)差异较大,满足最优标准、理想标准和最低标准的项目的平均偏差百分比分别为0.6% ~ 5.6%、1.0% ~ 9.6%和1.6% ~ 11.3%。结论:参与者的接受率和外部质量评价(EQA)结果在各标准质量等级上存在统计学差异。即使他们通过了EQA标准,测试结果也不能保证大数据的质量要求。我们建议KEQAS分类可以作为大数据建设的指南。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Laboratory Medicine
Annals of Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
8.30
自引率
12.20%
发文量
100
审稿时长
6-12 weeks
期刊介绍: Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.
期刊最新文献
Ability of the Capillary Electrophoresis-based HbA1c Assay to Detect Rare Hemoglobin Variants. Performance Evaluation of the LabGenius C-CT/NG-BMX Assay for Chlamydia trachomatis and Neisseria gonorrhoeae Detection. The First Korean Case of MAN1B1-Congenital Disorder of Glycosylation Diagnosed Using Whole-exome Sequencing and Matrix-assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry. Endogenous Thrombin Potential Level Helps Predict High Blood Loss in Patients Undergoing Cardiac Surgery. TP53 Mutation Status in Myelodysplastic Neoplasm and Acute Myeloid Leukemia: Impact of Reclassification Based on the 5th WHO and International Consensus Classification Criteria: A Korean Multicenter Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1