{"title":"Pediatric Epicardial Devices: Early and Midterm Outcomes.","authors":"Elaine M Griffeth, Prasad Krishnan, Joseph A Dearani, Siddharth Pahwa, Michael J Ackerman, Philip L Wackel, Austin Todd, Bryan C Cannon","doi":"10.1177/21501351231157374","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lead performance is suboptimal in young patients and a main cause of device system failure. Our objective was to assess early and midterm outcomes after epicardial device implantation in a contemporary pediatric cohort.</p><p><strong>Methods: </strong>A total of 116 consecutive pediatric patients underwent 137 epicardial device implantations from 2010 to 2019. Forty pacemakers and 97 implantable cardioverter defibrillators (ICDs) were implanted. Lead failure was defined as leads repaired, replaced, or abandoned due to fracture, dislodgement, or dysfunction. Freedom from device system failure was determined using Kaplan-Meier analysis.</p><p><strong>Results: </strong>Mean age at implantation was 10 ± 5 years, 46 (34%) were younger than 8 years old, 41 (30%) had prior cardiac surgery, and 38 (28%) had prior devices. Main indications were acquired heart block (17/40 [43%]), sinus node dysfunction (14/40 [35%]), and congenital heart block (7/40 [18%]) for pacemakers, and hypertrophic cardiomyopathy (46/97 [47%]), long QT syndrome (31/97 [32%]), and ventricular arrhythmia (17/97 [18%]) for ICDs. There were no early deaths. Three-year freedom from device system failure was 80% (95% CI 73%, 88%) for all patients and 88% (95% CI 79%, 99%) for patients <8 years old. Device system failure causes included lead fracture (20/34 [59%]), lead dysfunction (5/34 [15%]), lead dislodgement (5/34 [15%]), infection (3/34 [9%]), and pericarditis (1/34 [3%]). Reintervention was required in 26/34 (76%) device system failures.</p><p><strong>Conclusions: </strong>Epicardial device implantation is safe, shows acceptable midterm outcomes in children, and is an effective option in patients younger than 8 years old. Close device surveillance continues to be essential to detect lead failure early and ensure timely reintervention.</p>","PeriodicalId":23974,"journal":{"name":"World Journal for Pediatric and Congenital Heart Surgery","volume":"14 4","pages":"451-458"},"PeriodicalIF":1.1000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10330933/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal for Pediatric and Congenital Heart Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/21501351231157374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/2/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Lead performance is suboptimal in young patients and a main cause of device system failure. Our objective was to assess early and midterm outcomes after epicardial device implantation in a contemporary pediatric cohort.

Methods: A total of 116 consecutive pediatric patients underwent 137 epicardial device implantations from 2010 to 2019. Forty pacemakers and 97 implantable cardioverter defibrillators (ICDs) were implanted. Lead failure was defined as leads repaired, replaced, or abandoned due to fracture, dislodgement, or dysfunction. Freedom from device system failure was determined using Kaplan-Meier analysis.

Results: Mean age at implantation was 10 ± 5 years, 46 (34%) were younger than 8 years old, 41 (30%) had prior cardiac surgery, and 38 (28%) had prior devices. Main indications were acquired heart block (17/40 [43%]), sinus node dysfunction (14/40 [35%]), and congenital heart block (7/40 [18%]) for pacemakers, and hypertrophic cardiomyopathy (46/97 [47%]), long QT syndrome (31/97 [32%]), and ventricular arrhythmia (17/97 [18%]) for ICDs. There were no early deaths. Three-year freedom from device system failure was 80% (95% CI 73%, 88%) for all patients and 88% (95% CI 79%, 99%) for patients <8 years old. Device system failure causes included lead fracture (20/34 [59%]), lead dysfunction (5/34 [15%]), lead dislodgement (5/34 [15%]), infection (3/34 [9%]), and pericarditis (1/34 [3%]). Reintervention was required in 26/34 (76%) device system failures.

Conclusions: Epicardial device implantation is safe, shows acceptable midterm outcomes in children, and is an effective option in patients younger than 8 years old. Close device surveillance continues to be essential to detect lead failure early and ensure timely reintervention.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小儿心外膜装置:早期和中期结果
背景:年轻患者的导联性能不理想,是设备系统故障的主要原因。我们的目标是评估当代儿科患者心外膜装置植入术后的早期和中期预后:从 2010 年到 2019 年,共有 116 名连续的儿科患者接受了 137 次心外膜装置植入手术。其中植入了 40 个起搏器和 97 个植入式心律转复除颤器 (ICD)。导联故障的定义是导联因断裂、脱落或功能障碍而被修复、更换或放弃。采用 Kaplan-Meier 分析法确定设备系统无故障情况:植入时的平均年龄为 10 ± 5 岁,46 人(34%)小于 8 岁,41 人(30%)曾接受过心脏手术,38 人(28%)曾使用过装置。起搏器的主要适应症为获得性心脏传导阻滞(17/40 [43%])、窦房结功能障碍(14/40 [35%])和先天性心脏传导阻滞(7/40 [18%]),ICD的主要适应症为肥厚型心肌病(46/97 [47%])、长QT综合征(31/97 [32%])和室性心律失常(17/97 [18%])。无早期死亡病例。所有患者三年内无装置系统故障的比例为 80%(95% CI 73%,88%),患者无装置系统故障的比例为 88%(95% CI 79%,99%):心外膜装置植入是安全的,在儿童中显示出可接受的中期结果,是 8 岁以下患者的有效选择。严密的装置监测对于及早发现导联失效和确保及时再干预仍然至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
128
期刊最新文献
A Very Rare Cause of Dyspnea in a Child: A Hydatid Cyst From Echinococcus. Surgical Treatment of Pediatric Refractory Ventricular Tachycardia Originating From a Left Ventricular Rhabdomyoma. National In-Hospital Outcomes of Mechanical Mitral Valve Replacement in the Pediatric Population. En Bloc Resection of a Giant Ganglioneuroma of the Chest Through Clamshell Thoracotomy. Congestive Heart Failure in an Adolescent With a Ruptured Sinus of Valsalva Aneurysm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1