Elastic Deformation Measurement Using Duplex Ultrasound for the Detection of High Aneurysm Sac Pressure Following EVAR.

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Endovascular Therapy Pub Date : 2025-02-01 Epub Date: 2023-05-11 DOI:10.1177/15266028231172400
Olton S van Genderen, Rob C van Wissen, Jaap F Hamming, Jan van Schaik, Joost R van der Vorst
{"title":"Elastic Deformation Measurement Using Duplex Ultrasound for the Detection of High Aneurysm Sac Pressure Following EVAR.","authors":"Olton S van Genderen, Rob C van Wissen, Jaap F Hamming, Jan van Schaik, Joost R van der Vorst","doi":"10.1177/15266028231172400","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe the concept of aortic elastic deformation (ED) measurement using duplex ultrasonography (DUS) as a tool for detection of high aneurysm sac pressure following endovascular aortic repair (EVAR).</p><p><strong>Technique: </strong>High aneurysm sac pressure, with or without proven endoleak, will result in a less compressible aneurysm. Using the dual image function in B-mode of the DUS device and a standardized amount of applied probe pressure, ED can be measured. It is defined as the percentage of deformation of the aneurysm sac on probe pressure application. We hypothesize that less ED of the aneurysm sac can be related with high aneurysm sac pressure and possibly the presence of clinically relevant endoleak. In this note, we describe the technical details of the procedure and report on the applicability and results of ED measurements in the framework of aortic aneurysm and EVAR follow-up in a cohort of 109 patients.</p><p><strong>Conclusion: </strong>ED measurement is the first noninvasive pressure-based method in the quest to find a practical and reliable diagnostic tool to exclude high aneurysm sac pressure. In our patient cohort, patients with proven endoleak showed a smaller ED (less compressible), implying the presence of high aneurysm sac pressure. Further research should confirm whether ED measurement using DUS could reliably exclude endoleak after EVAR and further explore its potential for clinical application in EVAR follow-up.</p><p><strong>Clinical impact: </strong>For the first time, a simple, fast, and inexpensive diagnostic tool is presented in this study for detecting high sac pressure following EVAR. High sac pressure is typically caused by clinically significant endoleaks, which can have significant consequences. Currently, computed tomography scanning is the most common method used to identify and characterize endoleaks. However, measuring elastic deformation may potentially replace more invasive and expensive modalities, such as the computed tomography in the future.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"43-46"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11707957/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231172400","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To describe the concept of aortic elastic deformation (ED) measurement using duplex ultrasonography (DUS) as a tool for detection of high aneurysm sac pressure following endovascular aortic repair (EVAR).

Technique: High aneurysm sac pressure, with or without proven endoleak, will result in a less compressible aneurysm. Using the dual image function in B-mode of the DUS device and a standardized amount of applied probe pressure, ED can be measured. It is defined as the percentage of deformation of the aneurysm sac on probe pressure application. We hypothesize that less ED of the aneurysm sac can be related with high aneurysm sac pressure and possibly the presence of clinically relevant endoleak. In this note, we describe the technical details of the procedure and report on the applicability and results of ED measurements in the framework of aortic aneurysm and EVAR follow-up in a cohort of 109 patients.

Conclusion: ED measurement is the first noninvasive pressure-based method in the quest to find a practical and reliable diagnostic tool to exclude high aneurysm sac pressure. In our patient cohort, patients with proven endoleak showed a smaller ED (less compressible), implying the presence of high aneurysm sac pressure. Further research should confirm whether ED measurement using DUS could reliably exclude endoleak after EVAR and further explore its potential for clinical application in EVAR follow-up.

Clinical impact: For the first time, a simple, fast, and inexpensive diagnostic tool is presented in this study for detecting high sac pressure following EVAR. High sac pressure is typically caused by clinically significant endoleaks, which can have significant consequences. Currently, computed tomography scanning is the most common method used to identify and characterize endoleaks. However, measuring elastic deformation may potentially replace more invasive and expensive modalities, such as the computed tomography in the future.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用双超声测量弹性变形检测EVAR后动脉瘤囊高压力。
目的:描述用双工超声(DUS)测量主动脉弹性变形(ED)作为检测血管内主动脉修复(EVAR)后动脉瘤囊高压力的工具的概念。技术:高动脉瘤囊压力,无论有无证实的内漏,都会导致动脉瘤压缩性降低。利用DUS装置的b模式双图像功能和施加的标准探针压力量,可以测量ED。定义为探头施加压力时动脉瘤囊的变形百分比。我们推测动脉瘤囊ED的减少可能与动脉瘤囊压力高和可能存在临床相关的内漏有关。在这篇文章中,我们描述了手术的技术细节,并报告了ED测量在主动脉瘤和EVAR随访框架下的适用性和结果。结论:ED测量是第一个无创的基于压力的方法,旨在寻找一种实用可靠的诊断工具来排除高动脉瘤囊压力。在我们的患者队列中,证实有内漏的患者表现出较小的ED(可压缩性较差),这意味着存在较高的动脉瘤囊压力。进一步的研究应证实DUS测量ED是否能可靠地排除EVAR后的内漏,并进一步探讨其在EVAR随访中的临床应用潜力。临床影响:本研究首次提出了一种简单、快速、廉价的诊断工具,用于检测EVAR后的高囊压。高囊压通常是由临床显著的内漏引起的,这可能会产生严重的后果。目前,计算机断层扫描是最常用的方法,用于识别和表征内渗漏。然而,测量弹性变形可能会在未来取代更具侵入性和昂贵的方式,如计算机断层扫描。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
期刊最新文献
Percutaneous Superficial Temporal Artery Access Facilitating Carotid Artery Stenting Performed From Distal Radial Artery. Stent Implantation and Thromboendarterectomy for the Common Femoral Artery in Real-World Practice. Endovascular Treatment for Isolated Infected Iliac Artery Aneurysms. Initial Clinical Experience With AneuFix Injectable Biocompatible Elastomer for Translumbar Embolization of Type 2 Endoleaks. Long-Term Follow-up of Subjects With Iliac Occlusive Disease Treated With the Viabahn VBX Balloon-Expandable Endoprosthesis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1