{"title":"Excretion of Nitrogenous Waste Products from the Intestinal Fluid Simulator Using Super Absorbent Polymer: A New Generation Dialysis.","authors":"Behzad Abedi, Hamid Tayebi Khosroshahi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>End stage kidney disease (ESKD) is a life-threatening disorder, which results from loss of function of more than 75% of renal tissue. Many treatment modalities have been attempted for this disease, but only renal transplantation, hemodialysis and peritoneal dialysis have been practically accepted. Each of these methods have certain disadvantages, therefore other treatment modalities are needed for better management of these patients. Colonic dialysis (CD) has been proposed as one of the appropriate candidate methods for the removal of electrolytes, nitrogen waste products and excess fluid, using intestinal fluid environment.</p><p><strong>Methods: </strong>Super Absorbent Polymer (SAP) were synthesized to be used in CD. The intestinal fluid was simulated in terms of concentrations of nitrogenous waste products, electrolytes, temperature and pressure. The simulated environment was treated with 1 g of synthesized polymer at 37 °C. Concentrations of urea, creatinine and uric acid were measured before and after polymer treating.</p><p><strong>Results: </strong>Intestinal fluid simulator contained 40g urea, 0.3g creatinine, and 0.25g uric acid. SAP adsorbed up to 4000 to 4400% of its weight in the intestinal fluid simulator (1g polymer can absorb 40g fluid). The amount of urea, creatinine and uric acid decreased to 25g, 0.16g and 0.1g, respectively, in the intestinal fluid simulator.</p><p><strong>Conclusion: </strong>The present study showed that CD is an appropriate method for removal of electrolytes, nitrogenous waste products and excess fluid from an intestinal fluid simulator. Creatinine is absorbed appropriately in SAP, as a neutral molecule. In contrast, urea and uric acid, as weak acids, are absorbed weakly in polymer network. DOI: 10.52547/ijkd.6965.</p>","PeriodicalId":14610,"journal":{"name":"Iranian journal of kidney diseases","volume":"17 3","pages":"150-155"},"PeriodicalIF":0.8000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian journal of kidney diseases","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: End stage kidney disease (ESKD) is a life-threatening disorder, which results from loss of function of more than 75% of renal tissue. Many treatment modalities have been attempted for this disease, but only renal transplantation, hemodialysis and peritoneal dialysis have been practically accepted. Each of these methods have certain disadvantages, therefore other treatment modalities are needed for better management of these patients. Colonic dialysis (CD) has been proposed as one of the appropriate candidate methods for the removal of electrolytes, nitrogen waste products and excess fluid, using intestinal fluid environment.
Methods: Super Absorbent Polymer (SAP) were synthesized to be used in CD. The intestinal fluid was simulated in terms of concentrations of nitrogenous waste products, electrolytes, temperature and pressure. The simulated environment was treated with 1 g of synthesized polymer at 37 °C. Concentrations of urea, creatinine and uric acid were measured before and after polymer treating.
Results: Intestinal fluid simulator contained 40g urea, 0.3g creatinine, and 0.25g uric acid. SAP adsorbed up to 4000 to 4400% of its weight in the intestinal fluid simulator (1g polymer can absorb 40g fluid). The amount of urea, creatinine and uric acid decreased to 25g, 0.16g and 0.1g, respectively, in the intestinal fluid simulator.
Conclusion: The present study showed that CD is an appropriate method for removal of electrolytes, nitrogenous waste products and excess fluid from an intestinal fluid simulator. Creatinine is absorbed appropriately in SAP, as a neutral molecule. In contrast, urea and uric acid, as weak acids, are absorbed weakly in polymer network. DOI: 10.52547/ijkd.6965.
期刊介绍:
The Iranian Journal of Kidney Diseases (IJKD), a peer-reviewed journal in English, is the official publication of the Iranian Society of Nephrology. The aim of the IJKD is the worldwide reflection of the knowledge produced by the scientists and clinicians in nephrology. Published quarterly, the IJKD provides a new platform for advancement of the field. The journal’s objective is to serve as a focal point for debates and exchange of knowledge and experience among researchers in a global context. Original papers, case reports, and invited reviews on all aspects of the kidney diseases, hypertension, dialysis, and transplantation will be covered by the IJKD. Research on the basic science, clinical practice, and socio-economics of renal health are all welcomed by the editors of the journal.