Concurrent and Angle-Trajectory Validity and Intra-Trial Reliability of a Novel Multi-View Image-Based Motion Analysis System.

IF 1.9 3区 医学 Q2 SPORT SCIENCES Journal of Human Kinetics Pub Date : 2023-03-01 DOI:10.5114/jhk/159587
Namgi Lee, Junghoon Ahn, Wootaek Lim
{"title":"Concurrent and Angle-Trajectory Validity and Intra-Trial Reliability of a Novel Multi-View Image-Based Motion Analysis System.","authors":"Namgi Lee,&nbsp;Junghoon Ahn,&nbsp;Wootaek Lim","doi":"10.5114/jhk/159587","DOIUrl":null,"url":null,"abstract":"<p><p>Sports-related injuries are the most common in the lower extremities among physical regions. To evaluate impaired functional performance in sports training facilities and sports, a marker-less motion analysis system that can measure joint kinematics in bright indoor and outdoor environments is required. The aim of this study was to establish the concurrent and angle-trajectory validity and intra-trial reliability of a novel multi-view image-based motion analysis system with marker-less pose estimation during lower extremity tasks in healthy young men. Ten healthy young men participated voluntarily in this study. The hip and knee joint angles were collected using a multi-view image-based motion analysis system (marker-less) and a Vicon motion capture system (with markers) during the lower extremity tasks. Intraclass correlation coefficient (ICC) analyses were used to identify the concurrent and angle-trajectory validity and intra-trial reliability of the multi-view image-based motion analysis system. In the concurrent validity, the correlation analysis revealed that the ICC3, k values on the hip and knee flexions during knee bending in sitting, standing, and squat movements were from 0.747 to 0.936 between the two systems. In particular, the angle-trajectory validity was very high (ICC3, 1 = 0.859-0.998), indicating a high agreement between the two systems. The intra-trial reliability of each system was excellent (ICC3, 1 = 0.773-0.974), reflecting high reproducibility. We suggest that this novel marker-less motion analysis system is highly accurate and reliable for measuring joint kinematics of the lower extremities during the rehabilitation process and monitoring sports performance of athletes in training facilities.</p>","PeriodicalId":16055,"journal":{"name":"Journal of Human Kinetics","volume":"86 ","pages":"31-40"},"PeriodicalIF":1.9000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170539/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Human Kinetics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jhk/159587","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Sports-related injuries are the most common in the lower extremities among physical regions. To evaluate impaired functional performance in sports training facilities and sports, a marker-less motion analysis system that can measure joint kinematics in bright indoor and outdoor environments is required. The aim of this study was to establish the concurrent and angle-trajectory validity and intra-trial reliability of a novel multi-view image-based motion analysis system with marker-less pose estimation during lower extremity tasks in healthy young men. Ten healthy young men participated voluntarily in this study. The hip and knee joint angles were collected using a multi-view image-based motion analysis system (marker-less) and a Vicon motion capture system (with markers) during the lower extremity tasks. Intraclass correlation coefficient (ICC) analyses were used to identify the concurrent and angle-trajectory validity and intra-trial reliability of the multi-view image-based motion analysis system. In the concurrent validity, the correlation analysis revealed that the ICC3, k values on the hip and knee flexions during knee bending in sitting, standing, and squat movements were from 0.747 to 0.936 between the two systems. In particular, the angle-trajectory validity was very high (ICC3, 1 = 0.859-0.998), indicating a high agreement between the two systems. The intra-trial reliability of each system was excellent (ICC3, 1 = 0.773-0.974), reflecting high reproducibility. We suggest that this novel marker-less motion analysis system is highly accurate and reliable for measuring joint kinematics of the lower extremities during the rehabilitation process and monitoring sports performance of athletes in training facilities.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的基于多视角图像的运动分析系统的并发、角度轨迹有效性和试验内可靠性。
在身体区域中,运动相关损伤在下肢最常见。为了评估运动训练设施和运动中受损的功能表现,需要一种能够在明亮的室内和室外环境中测量关节运动学的无标记运动分析系统。本研究的目的是建立一种新的基于多视角图像的运动分析系统的并发效度和角度轨迹效度以及试验内信度,该系统在健康年轻男性的下肢任务中具有无标记姿态估计。10名健康的年轻男性自愿参加了这项研究。使用基于多视图图像的运动分析系统(无标记)和Vicon运动捕捉系统(有标记)收集下肢任务期间的髋关节和膝关节角度。采用类内相关系数(Intraclass correlation coefficient, ICC)分析了基于多视角图像的运动分析系统的并发效度、角度轨迹效度和试验内信度。在并发效度中,相关分析显示,坐姿、站立和深蹲动作中膝关节弯曲时的ICC3、k值在0.747 ~ 0.936之间。特别是角度-轨迹效度非常高(ICC3, 1 = 0.859-0.998),表明两种系统之间具有很高的一致性。各系统的试验内信度均较好(ICC3, 1 = 0.773-0.974),重复性高。我们认为,这种新型的无标记运动分析系统在测量康复过程中下肢关节运动学和监测运动员在训练设施中的运动表现方面具有很高的准确性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Human Kinetics
Journal of Human Kinetics 医学-运动科学
CiteScore
4.80
自引率
0.00%
发文量
83
审稿时长
3 months
期刊介绍: The Journal of Human Kinetics is an open access interdisciplinary periodical offering the latest research in the science of human movement studies. This comprehensive professional journal features articles and research notes encompassing such topic areas as: Kinesiology, Exercise Physiology and Nutrition, Sports Training and Behavioural Sciences in Sport, but especially considering elite and competitive aspects of sport. The journal publishes original papers, invited reviews, short communications and letters to the Editors. Manuscripts submitted to the journal must contain novel data on theoretical or experimental research or on practical applications in the field of sport sciences. The Journal of Human Kinetics is published in March, June, September and December. We encourage scientists from around the world to submit their papers to our periodical.
期刊最新文献
Habitual Running Style Matters: Duty Factor, and Not Stride Frequency, Relates to Loading Magnitude. Impact of the TTN C > T Polymorphism on Selected Variables of Aerobic and Anaerobic Capacity after a 12-Week Training Program. Increasing Braking and Amortization Forces during the Countermovement Jump Does Not Necessarily Improve Jump Height. Poor Joint Work in the Lower Limbs during a Tennis Forehand Groundstroke after a Cross-Over Step Inhibits an Increase in the Racket Speed. The Effect of Protective Mat Thickness on the Upper Limb Strike Force Simulation in Combat Sports and Self Defense.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1