Metal-ceramic resin-bonded fixed partical dentures after a mean observation time of 7.5 years.

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2023-05-24 DOI:10.11607/ijp.8296
Rebecca Handermann, Peter Rammelsberg, Wolfgang Bömicke
{"title":"Metal-ceramic resin-bonded fixed partical dentures after a mean observation time of 7.5 years.","authors":"Rebecca Handermann,&nbsp;Peter Rammelsberg,&nbsp;Wolfgang Bömicke","doi":"10.11607/ijp.8296","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the present study was to generate data on the long-term survival of metal-ceramic resin-bonded fixed partial dentures.</p><p><strong>Material and methods: </strong>Eighty-nine participants, received 94 RBFPDs, 5 (n women = 1; n men = 4) received 2 RBFPDs each. All RBFPDs were fabricated as two-retainer end-abutment metal-ceramic restorations. Clinical follow-ups were performed 6 weeks after cementation and annually thereafter. The mean observation time was 7.5 years. Cox regression was performed to test the effects of the variables sex, location, jaw, design, use of rubber dam, and adhesive luting system Survival and success were calculated by using Kaplan-Meier curves. As a secondary objective, patient and dentist satisfaction with the esthetics and function of the RBFPDs was evaluated. The significance level was set at α = .05 for all calculations.</p><p><strong>Results: </strong>Estimated Kaplan-Meier failure-free survival was 97.5% (standard error [SE] 1.7) after 5 years and 83.3% (SE 5.3) after 10 years. Calculated intervention-free survival (success) was 90.1% (SE 3.4) after 5 years and 65.5% (SE 6.7) after 10 years. Debonding-free survival was 92.6% (SE 2.9) after 5 years and 80.6% (SE 5.4) after 10 years. Cox regression revealed none of the four tested variables had a significant effect on the incidence of complications in RBFPDs. Patient and dentist satisfaction with RBFPD esthetics and function was consistently high throughout the observation period.</p><p><strong>Conclusions: </strong>Within the limitations of an observational study, RBFPDs achieved clinically successful outcomes over a mean observational period of 7.5 years.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.8296","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of the present study was to generate data on the long-term survival of metal-ceramic resin-bonded fixed partial dentures.

Material and methods: Eighty-nine participants, received 94 RBFPDs, 5 (n women = 1; n men = 4) received 2 RBFPDs each. All RBFPDs were fabricated as two-retainer end-abutment metal-ceramic restorations. Clinical follow-ups were performed 6 weeks after cementation and annually thereafter. The mean observation time was 7.5 years. Cox regression was performed to test the effects of the variables sex, location, jaw, design, use of rubber dam, and adhesive luting system Survival and success were calculated by using Kaplan-Meier curves. As a secondary objective, patient and dentist satisfaction with the esthetics and function of the RBFPDs was evaluated. The significance level was set at α = .05 for all calculations.

Results: Estimated Kaplan-Meier failure-free survival was 97.5% (standard error [SE] 1.7) after 5 years and 83.3% (SE 5.3) after 10 years. Calculated intervention-free survival (success) was 90.1% (SE 3.4) after 5 years and 65.5% (SE 6.7) after 10 years. Debonding-free survival was 92.6% (SE 2.9) after 5 years and 80.6% (SE 5.4) after 10 years. Cox regression revealed none of the four tested variables had a significant effect on the incidence of complications in RBFPDs. Patient and dentist satisfaction with RBFPD esthetics and function was consistently high throughout the observation period.

Conclusions: Within the limitations of an observational study, RBFPDs achieved clinically successful outcomes over a mean observational period of 7.5 years.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
金属陶瓷树脂粘接固定义齿平均观察时间7.5年。
目的:本研究的目的是获得金属-陶瓷树脂粘接固定义齿的长期生存数据。材料与方法:89例受试者,接受rbfpd治疗94例,女性5例(n = 1);n名男性= 4)每人接受2个rbfpd。所有rbfpd均制成双固位末端基台金属陶瓷修复体。术后6周进行临床随访,此后每年随访一次。平均观察时间7.5年。采用Cox回归检验性别、位置、颌骨、设计、使用橡胶坝和粘接系统等变量的影响,采用Kaplan-Meier曲线计算生存率和成功率。作为次要目标,评估患者和牙医对rbfpd的美学和功能的满意度。所有计算的显著性水平设为α = 0.05。结果:估计5年后Kaplan-Meier无失败生存率为97.5%(标准误差[SE] 1.7), 10年后为83.3%(标准误差[SE] 5.3)。5年后计算的无干预生存率(成功)为90.1% (SE 3.4), 10年后为65.5% (SE 6.7)。5年后无脱粘生存率为92.6% (SE 2.9), 10年后为80.6% (SE 5.4)。Cox回归分析显示,四个测试变量对rbfpd并发症发生率均无显著影响。在整个观察期间,患者和牙医对RBFPD的美观和功能的满意度一直很高。结论:在一项观察性研究的局限性内,rbfpd在平均7.5年的观察期内取得了临床成功的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1