{"title":"The effect of high-power short-duration pulmonary vein isolation on PWPT-a predictor of paroxysmal atrial fibrillation.","authors":"Meng Wang, Xiaochen Wang, Feng Gao, Pei Bao, Zheng Huang","doi":"10.1007/s00059-023-05198-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The P wave peak time (PWPT) is a predictor of paroxysmal atrial fibrillation (PAF). High-power short-duration ablation has been associated with improved durability of circumferential pulmonary vein electrical isolation (PVI). We investigated the effect of high-power short-duration PVI on PWPT in patients with PAF.</p><p><strong>Methods: </strong>Out of 111 patients with PAF, 91 received radiofrequency ablation (ablation group) and 20 received medication treatment (control group). A VIZIGO sheath and an STSF catheter (Biosense Webster, CA, USA) were used together for high-power short-duration circumferential PVI at ablation index values of 500 and 400 for the anterior and posterior walls, respectively. The patients were followed up for 12 months.</p><p><strong>Results: </strong>The preoperative PWPT in the ablation group was similar to that in the control group: PWPT II = 54.38 ± 6.18 ms vs. 54.35 ± 6.12 ms (p > 0.05), PWPT V<sub>1</sub> = 54.19 ± 6.21 ms vs. 54.31 ± 6.08 ms (p > 0.05), respectively. Circumferential PVI was achieved for all patients in the ablation group during the operation. At the 12-month follow-up, there were seven cases of AF recurrence. The PWPT in the ablation group 12 months postoperatively was shorter than the preoperative value: PWPT II = 49.39 ± 7.11 ms vs. 54.38 ± 6.18 ms (p < 0.001), PWPT V<sub>1</sub> = 47.69 ± 7.01 ms vs. 54.19 ± 6.21 ms (p < 0.001). The PWPT in the patients with AF recurrence was significantly longer than that in the non-recurrence patients: PWPT II = 50.48 ± 7.12 ms vs. 47.33 ± 6.21 ms (p < 0.001), PWPT V<sub>1</sub> = 50.84 ± 7.05 ms vs. 47.19 ± 6.27 ms, (p < 0.001). The PWPT of the control group at the 12-month follow-up was similar to the baseline level: PWPT II = 54.32 ± 6.20 ms vs. 54.35 ± 6.12 ms (p > 0.05), PWPT V<sub>1</sub> = 53.89 ± 6.01 ms vs. 54.31 ± 6.08 ms (p > 0.05).</p><p><strong>Conclusion: </strong>The results showed that high-power short-duration PVI had a positive effect on PWPT, which is a predictor of PAF.</p>","PeriodicalId":12863,"journal":{"name":"Herz","volume":" ","pages":"69-74"},"PeriodicalIF":1.1000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Herz","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00059-023-05198-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The P wave peak time (PWPT) is a predictor of paroxysmal atrial fibrillation (PAF). High-power short-duration ablation has been associated with improved durability of circumferential pulmonary vein electrical isolation (PVI). We investigated the effect of high-power short-duration PVI on PWPT in patients with PAF.
Methods: Out of 111 patients with PAF, 91 received radiofrequency ablation (ablation group) and 20 received medication treatment (control group). A VIZIGO sheath and an STSF catheter (Biosense Webster, CA, USA) were used together for high-power short-duration circumferential PVI at ablation index values of 500 and 400 for the anterior and posterior walls, respectively. The patients were followed up for 12 months.
Results: The preoperative PWPT in the ablation group was similar to that in the control group: PWPT II = 54.38 ± 6.18 ms vs. 54.35 ± 6.12 ms (p > 0.05), PWPT V1 = 54.19 ± 6.21 ms vs. 54.31 ± 6.08 ms (p > 0.05), respectively. Circumferential PVI was achieved for all patients in the ablation group during the operation. At the 12-month follow-up, there were seven cases of AF recurrence. The PWPT in the ablation group 12 months postoperatively was shorter than the preoperative value: PWPT II = 49.39 ± 7.11 ms vs. 54.38 ± 6.18 ms (p < 0.001), PWPT V1 = 47.69 ± 7.01 ms vs. 54.19 ± 6.21 ms (p < 0.001). The PWPT in the patients with AF recurrence was significantly longer than that in the non-recurrence patients: PWPT II = 50.48 ± 7.12 ms vs. 47.33 ± 6.21 ms (p < 0.001), PWPT V1 = 50.84 ± 7.05 ms vs. 47.19 ± 6.27 ms, (p < 0.001). The PWPT of the control group at the 12-month follow-up was similar to the baseline level: PWPT II = 54.32 ± 6.20 ms vs. 54.35 ± 6.12 ms (p > 0.05), PWPT V1 = 53.89 ± 6.01 ms vs. 54.31 ± 6.08 ms (p > 0.05).
Conclusion: The results showed that high-power short-duration PVI had a positive effect on PWPT, which is a predictor of PAF.
期刊介绍:
Herz is the high-level journal for further education for all physicians interested in cardiology. The individual issues of the journal each deal with specific topics and comprise review articles in English and German written by competent and esteemed authors. They provide up-to-date and comprehensive information concerning the speciality dealt with in the issue. Due to the fact that all relevant aspects of the pertinent topic of an issue are considered, an overview of the current status and progress in cardiology is presented. Reviews and original articles round off the spectrum of information provided.