Three-dimensional finite element study of mandibular first molar distalization with clear aligner.

Q3 Medicine 华西口腔医学杂志 Pub Date : 2023-08-01 DOI:10.7518/hxkq.2023.2023021
Fujia Kang, Lei Yu, Qi Zhang, Xinpeng Li, Zhiqiang Hu, Xianchun Zhu
{"title":"Three-dimensional finite element study of mandibular first molar distalization with clear aligner.","authors":"Fujia Kang, Lei Yu, Qi Zhang, Xinpeng Li, Zhiqiang Hu, Xianchun Zhu","doi":"10.7518/hxkq.2023.2023021","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to construct the finite element model of the mandibular first molar with the invisible appliance and explore the dentition movement characteristics of the mandibular first molar when using micro-implant anchorage and different initial positions of the first molar.</p><p><strong>Methods: </strong>Models of the mandible, tooth, periodontal membrane, and invisible appliance were constructed using cone beam computed tomography (CBCT) data. The two groups were divided into the non-anchorage group and the micro-implant group (between the roots of the first molar and the second molar) based on whether the elastic traction of the micro-implant was assisted or not. The two groups were divided into the following conditions based on the starting position of the first molar: Working condition 1: the distance between the first molar and the second premolar was 0 mm; working condition 2: the distance between the first molar and the second premolar was 1 mm; working condition 3: the distance between the first molar and the second premolar was 2 mm; working condition 4: the distance between the first molar and the second premolar was 3 mm. The data characte-ristics of total displacement and displacement in each direction of dentition were analyzed.</p><p><strong>Results: </strong>In the non-ancho-rage group, all the other teeth showed reverse movement except for the first molar which was moved distally. Meanwhile, in the micro-implant group, except for a small amount of mesial movement of the second molar in wor-king condition 1, the whole dentition in other working conditions presented distal movement and anterior teeth showed lingual movement, among which the distal displacement of the first molar in working condition 4 was the largest. With the change of the initial position of the first molar to the distal, the movement of the first molar to the distal, the premolar to the mesial, and the anterior to the lip increased, while the movement of the second molar to the mesial decreased.</p><p><strong>Conclusions: </strong>The micro-implant can effectively protect the anterior anchorage, increase the expression rate of molar distancing, and avoid the round-trip movement of the second molar. The initial position of the first molar movement is related to the amount of distancing and the remaining tooth movement.</p>","PeriodicalId":35800,"journal":{"name":"华西口腔医学杂志","volume":"41 4","pages":"405-413"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10372525/pdf/wcjs-41-04-405.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"华西口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7518/hxkq.2023.2023021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study aimed to construct the finite element model of the mandibular first molar with the invisible appliance and explore the dentition movement characteristics of the mandibular first molar when using micro-implant anchorage and different initial positions of the first molar.

Methods: Models of the mandible, tooth, periodontal membrane, and invisible appliance were constructed using cone beam computed tomography (CBCT) data. The two groups were divided into the non-anchorage group and the micro-implant group (between the roots of the first molar and the second molar) based on whether the elastic traction of the micro-implant was assisted or not. The two groups were divided into the following conditions based on the starting position of the first molar: Working condition 1: the distance between the first molar and the second premolar was 0 mm; working condition 2: the distance between the first molar and the second premolar was 1 mm; working condition 3: the distance between the first molar and the second premolar was 2 mm; working condition 4: the distance between the first molar and the second premolar was 3 mm. The data characte-ristics of total displacement and displacement in each direction of dentition were analyzed.

Results: In the non-ancho-rage group, all the other teeth showed reverse movement except for the first molar which was moved distally. Meanwhile, in the micro-implant group, except for a small amount of mesial movement of the second molar in wor-king condition 1, the whole dentition in other working conditions presented distal movement and anterior teeth showed lingual movement, among which the distal displacement of the first molar in working condition 4 was the largest. With the change of the initial position of the first molar to the distal, the movement of the first molar to the distal, the premolar to the mesial, and the anterior to the lip increased, while the movement of the second molar to the mesial decreased.

Conclusions: The micro-implant can effectively protect the anterior anchorage, increase the expression rate of molar distancing, and avoid the round-trip movement of the second molar. The initial position of the first molar movement is related to the amount of distancing and the remaining tooth movement.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用透明矫治器进行下颌第一磨牙远端矫治的三维有限元研究。
研究目的本研究旨在构建下颌第一磨牙与隐形矫治器的有限元模型,并探讨下颌第一磨牙在使用微型种植体固定和第一磨牙不同初始位置时的牙列移动特征:方法:利用锥形束计算机断层扫描(CBCT)数据构建下颌骨、牙齿、牙周膜和隐形矫治器的模型。根据是否辅助微型种植体的弹性牵引,分为非固定组和微型种植体组(位于第一磨牙和第二磨牙的牙根之间)。两组根据第一磨牙的起始位置分为以下几种情况:工作条件 1:第一磨牙和第二前磨牙之间的距离为 0 毫米;工作条件 2:第一磨牙和第二前磨牙之间的距离为 1 毫米;工作条件 3:第一磨牙和第二前磨牙之间的距离为 2 毫米;工作条件 4:第一磨牙和第二前磨牙之间的距离为 3 毫米。分析了牙列总位移和各方向位移的数据特征:结果:在非阻生组,除第一磨牙向远端移动外,其他牙齿均呈反向移动。同时,在微种植体组中,除了工作条件 1 中的第二磨牙有少量的中向移动外,其他工作条件中的整个牙列均呈远端移动,前牙呈舌向移动,其中工作条件 4 中的第一磨牙的远端位移最大。随着第一磨牙初始位置向远端移动,第一磨牙向远端移动、前磨牙向中侧移动、前牙向唇侧移动增加,而第二磨牙向中侧移动减少:结论:微型种植体可以有效保护前牙固位,提高臼齿间距的表达率,避免第二磨牙的往返移动。第一磨牙移动的初始位置与距离和剩余牙齿移动量有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
华西口腔医学杂志
华西口腔医学杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
6397
期刊介绍: West China Journal of Stomatology (WCJS, pISSN 1000-1182, eISSN 2618-0456, CN 51-1169/R), published bimonthly, is a peer-reviewed Open Access journal, hosted by Sichuan university and Ministry of Education of the People's Republic of China. WCJS was established in 1983 and indexed in Medline/Pubmed, SCOPUS, EBSCO, Chemical Abstract(CA), CNKI, WANFANG Data, etc.
期刊最新文献
Comparison of the efficacy and long-term stability of tunnel technique and coronally advanced flap in the treatment of gingival recession: a Meta-analysis. Intentional replantation for the retreatment of mandibular second molar: a case report. Simultaneous implantation and tooth preparation technology guided by 3D-printed guide. Three-dimensional reconstruction reveals the correlation between the extent of alveolar clefts and secondary nasal deformity in adults. Application of modified articular disc anchorage in treating the perforation and rupture of temporomandibular joint disc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1