Technical aspects that may affect the outcomes of pediatric patients with both-bone forearm diaphyseal fractures treated using elastic stable intramedullary nails.

IF 0.9 4区 医学 Q4 ORTHOPEDICS Journal of Pediatric Orthopaedics-Part B Pub Date : 2024-03-01 Epub Date: 2023-05-29 DOI:10.1097/BPB.0000000000001093
İdris Demirtaş, Zeynel Mert Asfuroğlu, Mehmet Çolak
{"title":"Technical aspects that may affect the outcomes of pediatric patients with both-bone forearm diaphyseal fractures treated using elastic stable intramedullary nails.","authors":"İdris Demirtaş, Zeynel Mert Asfuroğlu, Mehmet Çolak","doi":"10.1097/BPB.0000000000001093","DOIUrl":null,"url":null,"abstract":"<p><p>We assessed the radiological and functional results of pediatric both-bone forearm diaphyseal fractures treated using elastic stable intramedullary nails (ESINs), as well as factors affecting the results. In total, 36 patients (33 males and three females; mean age, 11.6 years) were included. The mean follow-up time was 41.5 (18-96) months. Patient demographic characteristics and the details of the surgical techniques were analyzed retrospectively. In addition to standard radiographic evaluations, the ratio between the nail diameter and medullary canal diameter (ND/MCD) was measured, as well as the maximal radial bowing. According to the criteria of Price and Flynn, 28 (77.8%) and eight (22.2%) patients had excellent and good results, respectively. There were no cases of nonunion or delayed union. There was no significant difference in functional or radiological results according to whether titanium nails (24 patients) or stainless steel nails (12 patients) were used (all P  > 0.05). Nail prebending (performed in 19 patients) did not affect the functional or radiological results ( P  > 0.05). Loss of reduction was observed in four patients with an ND/MCD ratio <40%. The maximal radial bowing improved in all patients. The mean change was significantly greater in patients with diastases and 22D/4.1 fractures. Regardless of nail type or prebending status, surgery using ESIN placement effectively treats both-bone forearm diaphyseal fractures; radial bow remodeling outcomes are excellent. We recommend that the ND/MCD ratio should be 40-70%.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":"178-183"},"PeriodicalIF":0.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001093","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

We assessed the radiological and functional results of pediatric both-bone forearm diaphyseal fractures treated using elastic stable intramedullary nails (ESINs), as well as factors affecting the results. In total, 36 patients (33 males and three females; mean age, 11.6 years) were included. The mean follow-up time was 41.5 (18-96) months. Patient demographic characteristics and the details of the surgical techniques were analyzed retrospectively. In addition to standard radiographic evaluations, the ratio between the nail diameter and medullary canal diameter (ND/MCD) was measured, as well as the maximal radial bowing. According to the criteria of Price and Flynn, 28 (77.8%) and eight (22.2%) patients had excellent and good results, respectively. There were no cases of nonunion or delayed union. There was no significant difference in functional or radiological results according to whether titanium nails (24 patients) or stainless steel nails (12 patients) were used (all P  > 0.05). Nail prebending (performed in 19 patients) did not affect the functional or radiological results ( P  > 0.05). Loss of reduction was observed in four patients with an ND/MCD ratio <40%. The maximal radial bowing improved in all patients. The mean change was significantly greater in patients with diastases and 22D/4.1 fractures. Regardless of nail type or prebending status, surgery using ESIN placement effectively treats both-bone forearm diaphyseal fractures; radial bow remodeling outcomes are excellent. We recommend that the ND/MCD ratio should be 40-70%.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用弹性稳定髓内钉治疗双骨前臂骺端骨折的儿科患者时,可能影响治疗效果的技术问题。
我们评估了使用弹性稳定髓内钉(ESIN)治疗小儿双骨前臂骺端骨折的放射学和功能效果,以及影响效果的因素。共纳入了 36 名患者(33 名男性,3 名女性;平均年龄 11.6 岁)。平均随访时间为 41.5 (18-96) 个月。对患者的人口统计学特征和手术技术细节进行了回顾性分析。除了标准的放射学评估外,还测量了髓内钉直径与髓管直径的比值(ND/MCD)以及最大桡侧弓度。根据普莱斯和弗林的标准,分别有28名(77.8%)和8名(22.2%)患者获得了优秀和良好的结果。没有出现不愈合或延迟愈合的病例。使用钛钉(24 例患者)还是不锈钢钉(12 例患者),在功能或放射学结果上没有明显差异(P 均大于 0.05)。钉子预弯(19 名患者)不会影响功能或放射学结果(P > 0.05)。四名患者的 ND/MCD 比值为
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.20
自引率
9.10%
发文量
170
审稿时长
4-8 weeks
期刊介绍: The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders. It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies). Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool. ​
期刊最新文献
Rigid intramedullary nailing of lower limb segments in children and adolescents with metabolic bone disease. Ultrasound evaluation of the femoral trochlea in newborns: incidence of trochlear dysplasia and associated risk factors. Outcomes of late-stages infantile Blount's disease managed by acute single stage: medial hemi-plateau elevation and metaphyseal osteotomy. Eight case series. Hemiepiphysiodesis using tension band plates: does the insertion technique or screw length influence the rate of correction? Understanding the recurrent pulled elbow.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1