A novel method for testing accuracy of bite registration using intraoral scanners.

IF 2.6 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Korean Journal of Orthodontics Pub Date : 2023-07-25 DOI:10.4041/kjod22.199
Lydia Kakali, Demetrios J Halazonetis
{"title":"A novel method for testing accuracy of bite registration using intraoral scanners.","authors":"Lydia Kakali,&nbsp;Demetrios J Halazonetis","doi":"10.4041/kjod22.199","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners.</p><p><strong>Methods: </strong>Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch.</p><p><strong>Results: </strong>The average maximum error in interocclusal registration exceeded 50 μm. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 μm or more. The models with acrylic teeth exhibited higher errors.</p><p><strong>Conclusions: </strong>A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.</p>","PeriodicalId":51260,"journal":{"name":"Korean Journal of Orthodontics","volume":"53 4","pages":"254-263"},"PeriodicalIF":2.6000,"publicationDate":"2023-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e8/38/kjod-53-4-254.PMC10387426.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod22.199","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners.

Methods: Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch.

Results: The average maximum error in interocclusal registration exceeded 50 μm. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 μm or more. The models with acrylic teeth exhibited higher errors.

Conclusions: A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种利用口腔内扫描仪检测咬合配准精度的新方法。
目的:关于口腔内扫描牙合定位准确性的证据很少。本研究旨在开发一种新的方法来评估口腔内扫描仪的咬合定位准确性。方法:采用两种不同类型的模型;10个石头模型和10个丙烯酸树脂牙齿。使用三维(3D)打印技术数字化设计和制造了一个三角形框架,每个顶点(一个前和两个后)都有圆柱形柱子。这样的结构被安装在每个上颌和下颌模型的舌腔中,这样,在咬合时,桩可以接触到相对的桩,在两个弓之间形成一个小的咬合间隙。这确保了牙齿之间没有干扰和完全接触。通过测量相对桩之间的距离来评估咬合准度,值越小表示精度越高。使用了三种口内扫描仪:Medit i500、Primescan和Trios 4。使用Viewbox软件测量相对立柱之间的距离,并计算横摇和俯仰。结果:牙合配准的平均最大误差超过50 μm。滚动和俯仰方向误差在0.1度以上,这意味着额外的咬合误差约为40 μm或更大。丙烯酸牙模型误差较大。结论:开发了一种方法,避免了对参考硬件的需要和在牙齿表面定位参考点的不精确性,并提供了使用口腔内扫描仪评估咬合的简单性。这些结果表明,口腔内扫描仪在再现咬合关系时可能会出现临床显著的错误。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.50
自引率
10.50%
发文量
48
审稿时长
>12 weeks
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
期刊最新文献
Effect of bone-borne maxillary skeletal expanders on cranial and circummaxillary sutures: A cone-beam computed tomography study. Comparison of the predicted and achieved labiolingual inclinations of the maxillary central incisors in adult Class II division 2 malocclusions treated with clear aligners. Evaluation of condylar dimension and position following rapid maxillary expansion with tooth- or tooth-bone-borne appliances. Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method. Factors affecting external apical root resorption of maxillary incisors associated with microimplant-assisted rapid palatal expansion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1