EFFECT OF IMMERSION IN WATER ON DEFORMATION WITH A VARIETY OF DENTURE BASE MATERIALS AND MANUFACTURING TECHNIQUES.

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2024-06-21 DOI:10.11607/ijp.8332
Po-Ju Huang, Tong-Mei Wang, Li-Deh Lin, Tsung- Chieh Yang
{"title":"EFFECT OF IMMERSION IN WATER ON DEFORMATION WITH A VARIETY OF DENTURE BASE MATERIALS AND MANUFACTURING TECHNIQUES.","authors":"Po-Ju Huang, Tong-Mei Wang, Li-Deh Lin, Tsung- Chieh Yang","doi":"10.11607/ijp.8332","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of immersion in water on deformation of maxillary denture bases created with CAD/CAM and heat-polymerized resin fabrication techniques under loading condi8ons.</p><p><strong>Materials and methods: </strong>2-mm-thick denture bases were fabricated using four techniques: CAD/CAM milling (CCM; Polywax PMMA blank, Yamachi PMMA disk Yamahachi Dental); 3D prin8ng (3DP; BV005, NextDent Base); compression molding (CM; Luciton 199, Dentsply Sirona); and injec8on molding (IM; Ivobase, Ivoclar; n = 5 per group). Three static 49-N loads were applied perpendicular to each denture base, and the mean strain value (MSV) was recorded with strain gauges a[ached to the denture surface. The denture bases were stored at 37°C in distilled water for 14 and 28 days, and the MSVs under the same static load were recorded.</p><p><strong>Results: </strong>The highest MSVs were observed at the posterior palatal seal, tuberosity, and labial notches of the dentures. The lowest MSVs were recorded for the CCM group and then the CM and IM groups. The highest MSVs were recorded for the 3DP group. No significant differences in regional MSVs (P > .05) were observed among the CCM, CM, and IM aber 14 and 28 days in water. Large devia8ons in MSVs were recorded for the 3DP group across the measurement sites aber water exposure (P < .05).</p><p><strong>Conclusions: </strong>CCM had the lowest denture deformation under static loading. After immersion in water, the deformation changes under static loading were stable for CCM, CM, and IM. However, variations among the materials used in 3DP group influenced the mechanical performance and presented larger deformations.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"123-135"},"PeriodicalIF":2.1000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.8332","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the effect of immersion in water on deformation of maxillary denture bases created with CAD/CAM and heat-polymerized resin fabrication techniques under loading condi8ons.

Materials and methods: 2-mm-thick denture bases were fabricated using four techniques: CAD/CAM milling (CCM; Polywax PMMA blank, Yamachi PMMA disk Yamahachi Dental); 3D prin8ng (3DP; BV005, NextDent Base); compression molding (CM; Luciton 199, Dentsply Sirona); and injec8on molding (IM; Ivobase, Ivoclar; n = 5 per group). Three static 49-N loads were applied perpendicular to each denture base, and the mean strain value (MSV) was recorded with strain gauges a[ached to the denture surface. The denture bases were stored at 37°C in distilled water for 14 and 28 days, and the MSVs under the same static load were recorded.

Results: The highest MSVs were observed at the posterior palatal seal, tuberosity, and labial notches of the dentures. The lowest MSVs were recorded for the CCM group and then the CM and IM groups. The highest MSVs were recorded for the 3DP group. No significant differences in regional MSVs (P > .05) were observed among the CCM, CM, and IM aber 14 and 28 days in water. Large devia8ons in MSVs were recorded for the 3DP group across the measurement sites aber water exposure (P < .05).

Conclusions: CCM had the lowest denture deformation under static loading. After immersion in water, the deformation changes under static loading were stable for CCM, CM, and IM. However, variations among the materials used in 3DP group influenced the mechanical performance and presented larger deformations.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在水中浸泡对各种义齿基托材料和制造技术变形的影响。
材料和方法:使用四种技术制作 2 毫米厚的义齿基托:CAD/CAM铣削(CCM;Polywax PMMA空白,Yamachi PMMA盘Yamahachi Dental);3D打印(3DP;BV005,NextDent Base);压缩成型(CM;Luciton 199,Dentsply Sirona);以及注射成型(IM;Ivobase,Ivoclar;每组n = 5)。在每个义齿基托上垂直施加三个 49-N 的静态载荷,并使用与义齿表面相接的应变片记录平均应变值 (MSV)。将义齿基托在 37°C 的蒸馏水中存放 14 天和 28 天,记录相同静态载荷下的平均应变值:结果:在义齿的后腭封、结节和唇切迹处观察到的 MSV 值最高,在义齿的后腭封、结节和唇切迹处观察到的 MSV 值最低。CCM 组的 MSV 值最低,然后是 CM 组和 IM 组。3DP 组的 MSV 值最高。在水中浸泡 14 天和 28 天后,CCM、CM 和 IM 之间的区域 MSV 无明显差异(P > .05)。3DP 组在水中暴露后各测量点的 MSV 值差异较大(P < .05):结论:在静态负荷下,CCM 的义齿变形最小。浸水后,CCM、CM 和 IM 在静态负荷下的变形变化稳定。然而,3DP 组所使用材料的不同会影响机械性能,并产生较大的变形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1