Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography-inter-observer and intra-observer reliability.

IF 2.3 4区 医学 Q2 ORTHOPEDICS Arthroplasty Pub Date : 2023-08-02 DOI:10.1186/s42836-023-00193-4
Tom Jan Gieroba, Sofia Marasco, Sina Babazadeh, Claudia Di Bella, Dirk van Bavel
{"title":"Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography-inter-observer and intra-observer reliability.","authors":"Tom Jan Gieroba, Sofia Marasco, Sina Babazadeh, Claudia Di Bella, Dirk van Bavel","doi":"10.1186/s42836-023-00193-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pre-operative alignment is important for knee procedures including total knee arthroplasty (TKA), especially when considering alternative alignments. The arithmetic Hip Knee Angle (aHKA) is a measure of coronal alignment calculated using the medial proximal tibial (MPTA) and lateral distal femoral angles (LDFA). Traditionally, aHKA is measured on long leg radiographs (LLR). This study assesses the reproducibility of aHKA measurement on LLR and robotic-assisted TKA planning CT.</p><p><strong>Methods: </strong>Sixty-eight TKA patients with pre-operative LLR and planning CTs were included. Three observers measured the LDFA, MPTA and aHKA three times on each modality and intra-observer and inter-observer reliability was calculated. Statistical analysis was undertaken with Pearson's r and the Bland-Altman test.</p><p><strong>Results: </strong>Mean intra-observer coefficient of repeatability (COR) for LLR vs. CT: MPTA 3.50° vs. 1.73°, LDFA 2.93° vs. 2.00° and aHKA 2.88° vs. 2.57° for CT. Inter-observer COR for LLR vs. CT: MPTA 2.74° vs. 1.28°, LDFA 2.31° vs. 1.92°, aHKA 3.56° vs. 2.00°. Mean intra-observer Pearson's r for MPTA was 0.93 for LLR and 0.94 for CT, LDFA 0.90 for LLR and 0.91 for CT and aHKA 0.92 for LLR and 0.94 for CT. Inter-observer Pearson's r for LLR compared to CT: MPTA 0.93 vs. 0.97, LDFA 0.91 vs. 0.90, aHKA 0.91 and 0.95.</p><p><strong>Conclusion: </strong>When compared to LLR, CT measurements of MPTA, LDFA and aHKA are more reproducible and have a good correlation with LLR measurement. CT overcomes difficulties with positioning, rotation, habitus and contractures when assessing coronal plane alignment and may obviate the need for LLRs.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10394810/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-023-00193-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pre-operative alignment is important for knee procedures including total knee arthroplasty (TKA), especially when considering alternative alignments. The arithmetic Hip Knee Angle (aHKA) is a measure of coronal alignment calculated using the medial proximal tibial (MPTA) and lateral distal femoral angles (LDFA). Traditionally, aHKA is measured on long leg radiographs (LLR). This study assesses the reproducibility of aHKA measurement on LLR and robotic-assisted TKA planning CT.

Methods: Sixty-eight TKA patients with pre-operative LLR and planning CTs were included. Three observers measured the LDFA, MPTA and aHKA three times on each modality and intra-observer and inter-observer reliability was calculated. Statistical analysis was undertaken with Pearson's r and the Bland-Altman test.

Results: Mean intra-observer coefficient of repeatability (COR) for LLR vs. CT: MPTA 3.50° vs. 1.73°, LDFA 2.93° vs. 2.00° and aHKA 2.88° vs. 2.57° for CT. Inter-observer COR for LLR vs. CT: MPTA 2.74° vs. 1.28°, LDFA 2.31° vs. 1.92°, aHKA 3.56° vs. 2.00°. Mean intra-observer Pearson's r for MPTA was 0.93 for LLR and 0.94 for CT, LDFA 0.90 for LLR and 0.91 for CT and aHKA 0.92 for LLR and 0.94 for CT. Inter-observer Pearson's r for LLR compared to CT: MPTA 0.93 vs. 0.97, LDFA 0.91 vs. 0.90, aHKA 0.91 and 0.95.

Conclusion: When compared to LLR, CT measurements of MPTA, LDFA and aHKA are more reproducible and have a good correlation with LLR measurement. CT overcomes difficulties with positioning, rotation, habitus and contractures when assessing coronal plane alignment and may obviate the need for LLRs.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
长腿X光片与计算机断层扫描的髋膝关节角算术测量--观察者之间和观察者内部的可靠性。
背景:术前对位对于包括全膝关节置换术(TKA)在内的膝关节手术非常重要,尤其是在考虑其他对位方式时。膝髋关节角度(aHKA)是通过胫骨内侧近端角(MPTA)和股骨外侧远端角(LDFA)计算得出的冠状位对齐度。传统上,aHKA 是通过长腿X光片(LLR)测量的。本研究评估了在 LLR 和机器人辅助 TKA 规划 CT 上测量 aHKA 的可重复性:方法:研究纳入了 68 名接受术前 LLR 和计划 CT 检查的 TKA 患者。三名观察者在每种模式下测量 LDFA、MPTA 和 aHKA 三次,并计算观察者内和观察者间的可靠性。统计分析采用 Pearson's r 和 Bland-Altman 检验:LLR与CT的平均观察者内重复性系数(COR):MPTA为3.50°,CT为1.73°;LDFA为2.93°,CT为2.00°;aHKA为2.88°,CT为2.57°。LLR 与 CT 的观察者间 COR:MPTA 2.74° vs. 1.28°,LDFA 2.31° vs. 1.92°,aHKA 3.56° vs. 2.00°。MPTA LLR 和 CT 的平均观测者内 Pearson's r 分别为 0.93 和 0.94,LDFA LLR 和 CT 的平均观测者内 Pearson's r 分别为 0.90 和 0.91,aHKA LLR 和 CT 的平均观测者内 Pearson's r 分别为 0.92 和 0.94。与 CT 相比,LLR 的观察者间皮尔逊 r:MPTA 为 0.93 vs. 0.97,LDFA 为 0.91 vs. 0.90,aHKA 为 0.91 和 0.95:与 LLR 相比,CT 对 MPTA、LDFA 和 aHKA 的测量具有更高的可重复性,并且与 LLR 测量具有良好的相关性。在评估冠状面排列时,CT 克服了定位、旋转、习性和挛缩方面的困难,因此可能不需要 LLR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Arthroplasty
Arthroplasty ORTHOPEDICS-
CiteScore
2.20
自引率
0.00%
发文量
49
审稿时长
15 weeks
期刊最新文献
A 10-point preoperative checklist: selecting patients for outpatient joint replacement surgery. Comparison of the safety and efficacy of three superficial skin closure methods for multi-layer wound closure in total knee arthroplasty: a multicenter, prospective, randomized controlled trial. Conversion of UKA to TKA using identical standard implants-How does it compare to primary UKA, primary TKA and revision TKA? Reliability of pre-resection ligament tension assessment in imageless robotic assisted total knee replacement. Should we be concerned when the anterior approach to the hip goes accidentally medial? A retrospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1