Influence of Mechanical Cycling on Torque Values of Tapped-In and Screw-In Implant-Supported Crowns.

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE European Journal of Prosthodontics and Restorative Dentistry Pub Date : 2023-05-31 DOI:10.1922/EJPRD_2411Ferreira05
R M Ferreira, A M Prado, M S Oliveira, R E Tonin, A A Mori, F Ferruzzi
{"title":"Influence of Mechanical Cycling on Torque Values of Tapped-In and Screw-In Implant-Supported Crowns.","authors":"R M Ferreira,&nbsp;A M Prado,&nbsp;M S Oliveira,&nbsp;R E Tonin,&nbsp;A A Mori,&nbsp;F Ferruzzi","doi":"10.1922/EJPRD_2411Ferreira05","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the influence of mechanical cycling on screwed-in and tappedin implants restored with screw-retained metallic crowns. Three implant-abutmentcrown systems were evaluated: T1 (multi abutment) and T2 (standard abutment) received tapped-in abutments and S received a screwed-in abutment. The specimens were subjected to two million cycles of 0-150 N load, at 2 Hz, 30° inclination in a dry medium, and torque evaluation. Survival and removal torque were analyzed using chisquare, ANOVA, followed by Tukey's test. Differences between installation and removal torque were determined using a T-test for dependent samples. Analyses were performed in SPSS, considering α = 0.05. All specimens survived mechanical cycling in S, 40% in T1, 80% in T2 (p=0.008). Failures occurred due to loosening of the crown screw. A significant decrease in torque (p=0.000) was found. Group T1 had the lowest removal torque (1.6 ± 0.84 N.Cm²), followed by T2 (3 ± 1.49 N.Cm²) and S (6.3 ± 1.16 N. Cm²), and a statistical difference was found between Groups T1 and S. Both types of implantabutment connections were stable and can be considered for rehabilitative treatment, but failure and removal torque were influenced by the design of prosthetic abutment. Crowns were more susceptible to becoming loose in tapped-in systems.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":"31 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2411Ferreira05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the influence of mechanical cycling on screwed-in and tappedin implants restored with screw-retained metallic crowns. Three implant-abutmentcrown systems were evaluated: T1 (multi abutment) and T2 (standard abutment) received tapped-in abutments and S received a screwed-in abutment. The specimens were subjected to two million cycles of 0-150 N load, at 2 Hz, 30° inclination in a dry medium, and torque evaluation. Survival and removal torque were analyzed using chisquare, ANOVA, followed by Tukey's test. Differences between installation and removal torque were determined using a T-test for dependent samples. Analyses were performed in SPSS, considering α = 0.05. All specimens survived mechanical cycling in S, 40% in T1, 80% in T2 (p=0.008). Failures occurred due to loosening of the crown screw. A significant decrease in torque (p=0.000) was found. Group T1 had the lowest removal torque (1.6 ± 0.84 N.Cm²), followed by T2 (3 ± 1.49 N.Cm²) and S (6.3 ± 1.16 N. Cm²), and a statistical difference was found between Groups T1 and S. Both types of implantabutment connections were stable and can be considered for rehabilitative treatment, but failure and removal torque were influenced by the design of prosthetic abutment. Crowns were more susceptible to becoming loose in tapped-in systems.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机械循环对自攻和自旋种植冠转矩值的影响。
本研究探讨了机械循环对螺钉保留金属冠的内固定和自攻种植体修复的影响。评估了三种种植体-基牙冠系统:T1(多基牙)和T2(标准基牙)采用攻入式基牙,S采用旋入式基牙。这些试件在干介质中承受了200万次0-150 N、2 Hz、30°倾角的载荷,并进行了扭矩评估。生存率和移除扭矩采用方差分析,然后进行Tukey检验。安装和拆卸扭矩之间的差异使用依赖样本的t检验来确定。采用SPSS进行分析,考虑α = 0.05。所有标本在S期机械循环成活率,T1期40%,T2期80% (p=0.008)。故障是由于冠螺钉松动造成的。发现扭矩显著降低(p=0.000)。T1组移除扭矩最小(1.6±0.84 N.Cm²),T2组次之(3±1.49 N.Cm²),S组为6.3±1.16 N.Cm²,两组间差异有统计学意义。两种种植体连接均稳定,可考虑进行康复治疗,但失败和移除扭矩受义肢基台设计的影响。在封闭系统中,冠更容易松动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
期刊最新文献
Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies. Performance of Fiberglass Posts Versus Fiber- Reinforced Resin Composites in Endodontically Treated Anterior Teeth Without Ferrule: A Systematic Review. Assessment of Efficacy of Implant Screwdrivers' During Multiple Tightening/ Untightening Cycles. An in vitro Study. Hybrid Full-Arch Rehabilitation Using Conventional And Zygomatic Implants: A Short-Term Retrospective Analysis. Clinical Survival of Indirect, Posterior Fiber-Reinforced Composite Fixed Dental Prosthesis: Up to 15 Years of Prospective Clinical Follow Up.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1