A review on the treatment of intimal hyperplasia with perivascular medical devices: role of mechanical factors and drug release kinetics.

IF 2.9 3区 医学 Q3 ENGINEERING, BIOMEDICAL Expert Review of Medical Devices Pub Date : 2023-07-01 Epub Date: 2023-08-10 DOI:10.1080/17434440.2023.2244875
Ankur J Raval, Jigisha K Parikh, Meghal A Desai
{"title":"A review on the treatment of intimal hyperplasia with perivascular medical devices: role of mechanical factors and drug release kinetics.","authors":"Ankur J Raval,&nbsp;Jigisha K Parikh,&nbsp;Meghal A Desai","doi":"10.1080/17434440.2023.2244875","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Intimal hyperplasia (IH) is a significant factor limiting the success of revascularization surgery for blood flow restoration. IH results from a foreign body response and mechanical disparity that involves complex biochemical reactions resulting in graft failure. The available treatment option utilizes either different pharmacological interventions or mechanical support to the vascular grafts with limited success.</p><p><strong>Areas covered: </strong>This review explains the pathophysiology of IH, responsible mechanical and biological factors, and treatment options, emphasizing perivascular devices. They are designed to provide mechanical support and pharmacology actions. The perivascular drug delivery concept has successfully demonstrated efficacy in various animal studies. Accurate projections of drug release mechanisms using mathematical modeling could be used to formulate prolonged drug elution devices. Numerical modeling aspects for the prediction of design outcomes have been given due importance that fulfills the unmet clinical need for better patient care.</p><p><strong>Expert opinion: </strong>IH could be effectively prevented by simultaneous mechanical scaffolding and sustained local drug delivery. Future perivascular medical devices could be designed to integrate these essential features. Numerical modeling for device performance prediction should be utilized in the development of next-generation perivascular devices.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2244875","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Intimal hyperplasia (IH) is a significant factor limiting the success of revascularization surgery for blood flow restoration. IH results from a foreign body response and mechanical disparity that involves complex biochemical reactions resulting in graft failure. The available treatment option utilizes either different pharmacological interventions or mechanical support to the vascular grafts with limited success.

Areas covered: This review explains the pathophysiology of IH, responsible mechanical and biological factors, and treatment options, emphasizing perivascular devices. They are designed to provide mechanical support and pharmacology actions. The perivascular drug delivery concept has successfully demonstrated efficacy in various animal studies. Accurate projections of drug release mechanisms using mathematical modeling could be used to formulate prolonged drug elution devices. Numerical modeling aspects for the prediction of design outcomes have been given due importance that fulfills the unmet clinical need for better patient care.

Expert opinion: IH could be effectively prevented by simultaneous mechanical scaffolding and sustained local drug delivery. Future perivascular medical devices could be designed to integrate these essential features. Numerical modeling for device performance prediction should be utilized in the development of next-generation perivascular devices.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血管周围医疗器械治疗内膜增生综述:机械因素和药物释放动力学的作用。
引言:内膜增生(IH)是限制血运重建手术成功的一个重要因素。IH是由异物反应和机械差异引起的,机械差异涉及导致移植物衰竭的复杂生化反应。可用的治疗方案利用不同的药物干预或对血管移植物的机械支持,但成功率有限。涵盖的领域:这篇综述解释了IH的病理生理学,主要的机械和生物因素,以及治疗选择,重点是血管周围装置。它们旨在提供机械支持和药理学作用。血管周围给药的概念已经在各种动物研究中成功证明了疗效。使用数学模型精确预测药物释放机制可用于制定延长的药物洗脱装置。用于预测设计结果的数值建模方面已经得到了应有的重视,以满足对更好患者护理的未满足的临床需求。专家意见:IH可以通过同时进行机械支架和持续的局部给药来有效预防。未来的血管周围医疗设备可以设计成集成这些基本功能。在开发下一代血管周围设备时,应使用设备性能预测的数值建模。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Expert Review of Medical Devices
Expert Review of Medical Devices 医学-工程:生物医学
CiteScore
5.90
自引率
3.20%
发文量
69
审稿时长
6-12 weeks
期刊介绍: The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections: Expert commentary - a personal view on the most effective or promising strategies Five-year view - a clear perspective of future prospects within a realistic timescale Key issues - an executive summary cutting to the author''s most critical points In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.
期刊最新文献
Future perspectives and challenges of artificial intelligence implementation in remote monitoring of cardiac implantable electronic devices. His bundle pacing combined with atrioventricular node ablation for atrial fibrillation: a systematic review and meta-analysis. Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database. Thoracic impedance monitoring in heart failure: from theory to practice. Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1