{"title":"[Determination of human serum total protein via electrophoresis titration and capacitively coupled contactless conductivity detection].","authors":"Rui-Hua Zhang, Ze-Hua Guo, Qiang Zhang, Gen-Han Zha, Cheng-Xi Cao, Liu-Yin Fan, Wei-Wen Liu","doi":"10.3724/SP.J.1123.2023.04015","DOIUrl":null,"url":null,"abstract":"<p><p>Serum total protein refers to the sum of all proteins in the serum, and its content determination is relevant to human health monitoring and disease diagnosis. However, existing detection techniques present a number of limitations; for example, the Kjeldahl method suffers from the negative effects of interfering substances such as non-protein nitrogen (NPN). Although the electrophoresis titration (ET) method has solved interference problems to some extent, the current ET technique relies on optical detection methods, which increases the tediousness of the operation. This study addresses the challenge of accurate serum total protein detection by combining the traditional ET technique with capacitively coupled contactless conductivity detection (C<sup>4</sup>D). The research contributions of this work are multifold. First, it presents the first development of an ET-C<sup>4</sup>D detection system, which consists of six components: an ET power module, an ET chip, a C<sup>4</sup>D sensing module, a detection module, a data acquisition card, and software. The developed system can capture the conductivity of substances in the channel using the software developed by our laboratory during ET. The detection system can be used to quantify the total protein content in human serum without the addition of specific labeling reagents or using optical detection equipment, and its running time is approximately 300 s. Second, this research proposes the corresponding principle of the system. Under an electric field, ion migration results in different pH levels before and after the boundary, leading to a protein surface charge difference. The maintenance of the electrical neutrality of the substances in the detection channel is related to the protein surface charge; therefore, the ion concentration distribution of the substances in the detection channel changes as the protein surface charge varies. A plot of conductivity as a function of running time showed an \"inverted clock shape\", first falling and then rising. Owing to the addition of different types and concentrations of proteins, the microenvironment of the entire system changes, resulting in different changes in conductivity. Third, the performance of the detection system was tested using human serum albumin (HSA) standard protein, which was mixed with polyacrylamide gel (PAG) mother liquor, riboflavin, etc., and irradiated under ultraviolet light for 10 min to form a gel. The ET experiments were then carried out. The shape of the conductivity curve was consistent with the proposed principle, and the higher the HSA concentration, the lower the conductivity curve trough, followed by a lagged time of the trough. Quantitative analysis of the conductivity signals showed that the linear range was 0.25-3.00 g/L, with a linearity of up to 0.98. The limit of detection (LOD) was 0.01 g/L, the relative standard deviation (RSD) was 1.90%, and the relative error of the test values was <7.20%, indicating the good detection stability and sensitivity of the system. Clinical samples collected from healthy volunteers were used as target blood samples for serum total protein content measurement using our detection system. Blood samples from a volunteer were used to obtain a standard curve, and the serum samples of other four volunteers were selected for ET-C<sup>4</sup>D and biuret detection. The results showed that the relative errors between the two methods were within 4.43%, indicating the accuracy and reliability of the detection system. The advantages of the ET-C<sup>4</sup>D detection system proposed in this paper are as follows: (i) ET-C<sup>4</sup>D realizes the rapid detection of total serum protein content based on the ET technique; (ii) compared with the traditional protein ET technique, the ET-C<sup>4</sup>D method does not rely on specific labeling components or optical detection equipment, thereby reducing the complexity of the operation; and (iii) the output signal of ET-C<sup>4</sup>D can be used for quantitative analysis with excellent analytical performance and high accuracy. These merits highlight the potential of the developed system for clinical application and biochemical analysis.</p>","PeriodicalId":9864,"journal":{"name":"色谱","volume":"41 8","pages":"707-713"},"PeriodicalIF":1.2000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398821/pdf/cjc-41-08-707.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"色谱","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2023.04015","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Serum total protein refers to the sum of all proteins in the serum, and its content determination is relevant to human health monitoring and disease diagnosis. However, existing detection techniques present a number of limitations; for example, the Kjeldahl method suffers from the negative effects of interfering substances such as non-protein nitrogen (NPN). Although the electrophoresis titration (ET) method has solved interference problems to some extent, the current ET technique relies on optical detection methods, which increases the tediousness of the operation. This study addresses the challenge of accurate serum total protein detection by combining the traditional ET technique with capacitively coupled contactless conductivity detection (C4D). The research contributions of this work are multifold. First, it presents the first development of an ET-C4D detection system, which consists of six components: an ET power module, an ET chip, a C4D sensing module, a detection module, a data acquisition card, and software. The developed system can capture the conductivity of substances in the channel using the software developed by our laboratory during ET. The detection system can be used to quantify the total protein content in human serum without the addition of specific labeling reagents or using optical detection equipment, and its running time is approximately 300 s. Second, this research proposes the corresponding principle of the system. Under an electric field, ion migration results in different pH levels before and after the boundary, leading to a protein surface charge difference. The maintenance of the electrical neutrality of the substances in the detection channel is related to the protein surface charge; therefore, the ion concentration distribution of the substances in the detection channel changes as the protein surface charge varies. A plot of conductivity as a function of running time showed an "inverted clock shape", first falling and then rising. Owing to the addition of different types and concentrations of proteins, the microenvironment of the entire system changes, resulting in different changes in conductivity. Third, the performance of the detection system was tested using human serum albumin (HSA) standard protein, which was mixed with polyacrylamide gel (PAG) mother liquor, riboflavin, etc., and irradiated under ultraviolet light for 10 min to form a gel. The ET experiments were then carried out. The shape of the conductivity curve was consistent with the proposed principle, and the higher the HSA concentration, the lower the conductivity curve trough, followed by a lagged time of the trough. Quantitative analysis of the conductivity signals showed that the linear range was 0.25-3.00 g/L, with a linearity of up to 0.98. The limit of detection (LOD) was 0.01 g/L, the relative standard deviation (RSD) was 1.90%, and the relative error of the test values was <7.20%, indicating the good detection stability and sensitivity of the system. Clinical samples collected from healthy volunteers were used as target blood samples for serum total protein content measurement using our detection system. Blood samples from a volunteer were used to obtain a standard curve, and the serum samples of other four volunteers were selected for ET-C4D and biuret detection. The results showed that the relative errors between the two methods were within 4.43%, indicating the accuracy and reliability of the detection system. The advantages of the ET-C4D detection system proposed in this paper are as follows: (i) ET-C4D realizes the rapid detection of total serum protein content based on the ET technique; (ii) compared with the traditional protein ET technique, the ET-C4D method does not rely on specific labeling components or optical detection equipment, thereby reducing the complexity of the operation; and (iii) the output signal of ET-C4D can be used for quantitative analysis with excellent analytical performance and high accuracy. These merits highlight the potential of the developed system for clinical application and biochemical analysis.
期刊介绍:
"Chinese Journal of Chromatography" mainly reports the basic research results of chromatography, important application results of chromatography and its interdisciplinary subjects and their progress, including the application of new methods, new technologies, and new instruments in various fields, the research and development of chromatography instruments and components, instrument analysis teaching research, etc. It is suitable for researchers engaged in chromatography basic and application technology research in scientific research institutes, master and doctoral students in chromatography and related disciplines, grassroots researchers in the field of analysis and testing, and relevant personnel in chromatography instrument development and operation units.
The journal has columns such as special planning, focus, perspective, research express, research paper, monograph and review, micro review, technology and application, and teaching research.