A Randomized Controlled Trial Comparing BioMime Sirolimus-Eluting Stent With Everolimus-Eluting Stent: Two-Year Outcomes of the meriT-V Trial.

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiology Research Pub Date : 2023-08-01 DOI:10.14740/cr1498
Alexandre Abizaid, Ricardo Costa, Sasko Kedev, Elvin Kedhi, Suneel Talwar, Andrejs Erglis, Ota Hlinomaz, Monica Masotti, Farzin Fath-Ordoubadi, Krzysztof Milewski, Pedro Lemos, Roberto Botelho, Alexander Ijsselmuiden, Jacques Koolen, Petr Kala, Luc Janssens, Udita Chandra
{"title":"A Randomized Controlled Trial Comparing BioMime Sirolimus-Eluting Stent With Everolimus-Eluting Stent: Two-Year Outcomes of the meriT-V Trial.","authors":"Alexandre Abizaid,&nbsp;Ricardo Costa,&nbsp;Sasko Kedev,&nbsp;Elvin Kedhi,&nbsp;Suneel Talwar,&nbsp;Andrejs Erglis,&nbsp;Ota Hlinomaz,&nbsp;Monica Masotti,&nbsp;Farzin Fath-Ordoubadi,&nbsp;Krzysztof Milewski,&nbsp;Pedro Lemos,&nbsp;Roberto Botelho,&nbsp;Alexander Ijsselmuiden,&nbsp;Jacques Koolen,&nbsp;Petr Kala,&nbsp;Luc Janssens,&nbsp;Udita Chandra","doi":"10.14740/cr1498","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of <i>de novo</i> lesions.</p><p><strong>Methods: </strong>The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions.</p><p><strong>Results: </strong>The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16).</p><p><strong>Conclusions: </strong>The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.</p>","PeriodicalId":9424,"journal":{"name":"Cardiology Research","volume":"14 4","pages":"291-301"},"PeriodicalIF":1.4000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fb/d5/cr-14-291.PMC10409544.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/cr1498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions.

Methods: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions.

Results: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16).

Conclusions: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较BioMime西罗莫司洗脱支架和依维莫司洗脱支架的随机对照试验:优点- v试验的两年结果。
背景:基于生物可降解聚合物(bp)的药物洗脱支架(DESs)已经被引入,以降低晚期和极晚期支架血栓形成(ST)的风险,这在早期基于耐用聚合物(DPs)的药物洗脱支架设计中经常观察到;然而,这些DES设计的随机对照试验很少。优点- v试验是一项随机、主动对照、非效性试验,具有前瞻性、多中心设计,评估了新型第三代超薄支柱、基于bp的BioMime西罗莫司洗脱支架(SES)与基于dp的XIENCE依维莫司洗脱支架(EES)治疗新发病变的2年疗效。方法:meriT-V是一项随机试验,在欧洲和巴西的15个中心招募了256名患者。在此,我们报告了延长随访期2年的结果。入组患者的随机化比例为2:1;入组患者接受BioMime SES (n = 170)或XIENCE EES (n = 86)。三点主要心脏不良事件(MACE),定义为心源性死亡、心肌梗死(MI)或缺血驱动的靶血管重血化(ID-TVR)的复合,被视为复合安全性和有效性终点。根据第一个学术研究联盟的定义,评估缺血驱动的靶病变血运重建术(ID-TLR)以及确定/可能ST的频率。结果:该试验2年随访完成率为98.44% (n = 252/256例患者),临床结局评估显示,两组患者累积3点MACE率差异无统计学意义(BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62)。即使是BioMime组的心肌梗死发生率也低于XIENCE组(1.79% vs. 5.95%, P = 0.17)。XIENCE组1.19%的患者出现晚ST,而BioMime组未出现晚ST (P = 0.16)。结论:在这项随机对照试验中,基于bp的新型BioMime SES和基于bp的成熟的XIENCE EES之间的客观比较显示,这两种设备在心脏死亡、MI、ID-TVR和st方面的结果都是可以接受的。此外,由于整个研究样本在2年的过程中没有发生心脏死亡,我们认为研究结果对这两种DES设计都非常重要。在这项初步的比较试验中,考虑到BioMime组在2年期间较低的3点MACE率和没有晚期ST,可以肯定BioMime SES的设备安全性是可以接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cardiology Research
Cardiology Research CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.50
自引率
0.00%
发文量
42
期刊介绍: Cardiology Research is an open access, peer-reviewed, international journal. All submissions relating to basic research and clinical practice of cardiology and cardiovascular medicine are in this journal''s scope. This journal focuses on publishing original research and observations in all cardiovascular medicine aspects. Manuscript types include original article, review, case report, short communication, book review, letter to the editor.
期刊最新文献
Advances in the Understanding and Treatment of Chronic Chagas Cardiomyopathy. Detection of Left Atrial Remodeling by Three-Dimensional Echocardiography in Symptomatic Patients Known to Had Non-Obstructive Hypertrophic Cardiomyopathy. Diverse Concepts in Definitions of Dilated Cardiomyopathy: Theory and Practice. Effect of Post-Loop Diuretic Urinary Sodium Level on Length of Stay and Rehospitalization in Acutely Decompensated Heart Failure Patients. Evaluating the Prognostic Value of the Modified H2FPEF Score in Patients With Heart Failure With Preserved Ejection Fraction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1