{"title":"新术区分类指导种植体引导方法的临床决策。","authors":"Haiyang Yu, Jiacheng Wu, Nan Hu","doi":"10.7518/hxkq.2023.2022386","DOIUrl":null,"url":null,"abstract":"<p><p>When selecting implant guidance methods or judging whether the patient can be implanted, many doctors ignore or only use visual inspection to estimate a patient's mouth opening. This phenomenon often leads to failure to complete the implantation due to insufficient mouth opening or the deflection of the implant due to limited angle, resulting in the high incidence of corresponding complications. The main reason is that doctors lack accurate analysis and control of the overall geometric conditions of the intraoral surgical area, and three-dimensional position blocking of surgical instruments occurs during the operation. In the past, mouth opening was defined as the distance between the incisor edges of the upper and lower central incisors when the patient opens his mouth widely, and the implant area could be in any missing tooth position. When it is in the posterior tooth area, the specific measurement scheme of the mouth opening could not be simply equivalent to the previous measurement method in the anterior tooth area. However, how to measure quickly and conveniently the mouth opening of any surgical area to determine whether it could be implanted and meet the needs of the selected guidance method remains unclear. This paper introduces new concepts, establishes new classification and corresponding accurate measurement scheme of implant area, and establishes a decision tree of implant methods guided by the actually measured value. Results provide a quantitative basis for rational formulation and implementation of implant treatment.</p>","PeriodicalId":35800,"journal":{"name":"华西口腔医学杂志","volume":"41 2","pages":"134-139"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427254/pdf/wcjs-41-02-134.pdf","citationCount":"0","resultStr":"{\"title\":\"Clinical decision making of implant guidance methods guided by new classification of surgical area mouth ope-ning.\",\"authors\":\"Haiyang Yu, Jiacheng Wu, Nan Hu\",\"doi\":\"10.7518/hxkq.2023.2022386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>When selecting implant guidance methods or judging whether the patient can be implanted, many doctors ignore or only use visual inspection to estimate a patient's mouth opening. This phenomenon often leads to failure to complete the implantation due to insufficient mouth opening or the deflection of the implant due to limited angle, resulting in the high incidence of corresponding complications. The main reason is that doctors lack accurate analysis and control of the overall geometric conditions of the intraoral surgical area, and three-dimensional position blocking of surgical instruments occurs during the operation. In the past, mouth opening was defined as the distance between the incisor edges of the upper and lower central incisors when the patient opens his mouth widely, and the implant area could be in any missing tooth position. When it is in the posterior tooth area, the specific measurement scheme of the mouth opening could not be simply equivalent to the previous measurement method in the anterior tooth area. However, how to measure quickly and conveniently the mouth opening of any surgical area to determine whether it could be implanted and meet the needs of the selected guidance method remains unclear. This paper introduces new concepts, establishes new classification and corresponding accurate measurement scheme of implant area, and establishes a decision tree of implant methods guided by the actually measured value. Results provide a quantitative basis for rational formulation and implementation of implant treatment.</p>\",\"PeriodicalId\":35800,\"journal\":{\"name\":\"华西口腔医学杂志\",\"volume\":\"41 2\",\"pages\":\"134-139\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427254/pdf/wcjs-41-02-134.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"华西口腔医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.7518/hxkq.2023.2022386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"华西口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7518/hxkq.2023.2022386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Clinical decision making of implant guidance methods guided by new classification of surgical area mouth ope-ning.
When selecting implant guidance methods or judging whether the patient can be implanted, many doctors ignore or only use visual inspection to estimate a patient's mouth opening. This phenomenon often leads to failure to complete the implantation due to insufficient mouth opening or the deflection of the implant due to limited angle, resulting in the high incidence of corresponding complications. The main reason is that doctors lack accurate analysis and control of the overall geometric conditions of the intraoral surgical area, and three-dimensional position blocking of surgical instruments occurs during the operation. In the past, mouth opening was defined as the distance between the incisor edges of the upper and lower central incisors when the patient opens his mouth widely, and the implant area could be in any missing tooth position. When it is in the posterior tooth area, the specific measurement scheme of the mouth opening could not be simply equivalent to the previous measurement method in the anterior tooth area. However, how to measure quickly and conveniently the mouth opening of any surgical area to determine whether it could be implanted and meet the needs of the selected guidance method remains unclear. This paper introduces new concepts, establishes new classification and corresponding accurate measurement scheme of implant area, and establishes a decision tree of implant methods guided by the actually measured value. Results provide a quantitative basis for rational formulation and implementation of implant treatment.
期刊介绍:
West China Journal of Stomatology (WCJS, pISSN 1000-1182, eISSN 2618-0456, CN 51-1169/R), published bimonthly, is a peer-reviewed Open Access journal, hosted by Sichuan university and Ministry of Education of the People's Republic of China. WCJS was established in 1983 and indexed in Medline/Pubmed, SCOPUS, EBSCO, Chemical Abstract(CA), CNKI, WANFANG Data, etc.