基于h扫描的超声同差- k对比加权和参数成像检测微波消融区。

IF 2.5 4区 医学 Q1 ACOUSTICS Ultrasonic Imaging Pub Date : 2023-05-01 DOI:10.1177/01617346231162928
Sinan Li, Zhuhuang Zhou, Shuicai Wu, Weiwei Wu
{"title":"基于h扫描的超声同差- k对比加权和参数成像检测微波消融区。","authors":"Sinan Li,&nbsp;Zhuhuang Zhou,&nbsp;Shuicai Wu,&nbsp;Weiwei Wu","doi":"10.1177/01617346231162928","DOIUrl":null,"url":null,"abstract":"<p><p>The homodyned-K (HK) distribution is a generalized model of envelope statistics whose parameters <i>α</i> (the clustering parameter) and <i>k</i> (the coherent-to-diffuse signal ratio) can be used to monitor the thermal lesions. In this study, we proposed an ultrasound HK contrast-weighted summation (CWS) parametric imaging algorithm based on the H-scan technique and investigated the optimal window side length (WSL) of the HK parameters estimated by the XU estimator (an estimation method based on the first moment of the intensity and two log-moments, which was used in the proposed algorithm) through phantom simulations. H-scan diversified ultrasonic backscattered signals into low- and high-frequency passbands. After envelope detection and HK parameter estimation for each frequency band, the <i>α</i> and <i>k</i> parametric maps were obtained, respectively. According to the contrast between the target region and background, the (<i>α</i> or <i>k</i>) parametric maps of the dual-frequency band were weighted and summed, and then the CWS images were yielded by pseudo-color imaging. The proposed HK CWS parametric imaging algorithm was used to detect the microwave ablation coagulation zones of porcine liver ex vivo under different powers and treatment durations. The performance of the proposed algorithm was compared with that of the conventional HK parametric imaging and frequency diversity and compounding Nakagami imaging algorithms. For two-dimensional HK parametric imaging, it was found that a WSL equal to 4 pulse lengths of the transducer was sufficient for estimating the <i><i>α</i></i> and <i>k</i> parameters in terms of both parameter estimation stability and parametric imaging resolution. The HK CWS parametric imaging provided an improved contrast-to-noise ratio over conventional HK parametric imaging, and the HK <i>α</i><sub>cws</sub> parametric imaging achieved the best accuracy and Dice score of coagulation zone detection.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones.\",\"authors\":\"Sinan Li,&nbsp;Zhuhuang Zhou,&nbsp;Shuicai Wu,&nbsp;Weiwei Wu\",\"doi\":\"10.1177/01617346231162928\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The homodyned-K (HK) distribution is a generalized model of envelope statistics whose parameters <i>α</i> (the clustering parameter) and <i>k</i> (the coherent-to-diffuse signal ratio) can be used to monitor the thermal lesions. In this study, we proposed an ultrasound HK contrast-weighted summation (CWS) parametric imaging algorithm based on the H-scan technique and investigated the optimal window side length (WSL) of the HK parameters estimated by the XU estimator (an estimation method based on the first moment of the intensity and two log-moments, which was used in the proposed algorithm) through phantom simulations. H-scan diversified ultrasonic backscattered signals into low- and high-frequency passbands. After envelope detection and HK parameter estimation for each frequency band, the <i>α</i> and <i>k</i> parametric maps were obtained, respectively. According to the contrast between the target region and background, the (<i>α</i> or <i>k</i>) parametric maps of the dual-frequency band were weighted and summed, and then the CWS images were yielded by pseudo-color imaging. The proposed HK CWS parametric imaging algorithm was used to detect the microwave ablation coagulation zones of porcine liver ex vivo under different powers and treatment durations. The performance of the proposed algorithm was compared with that of the conventional HK parametric imaging and frequency diversity and compounding Nakagami imaging algorithms. For two-dimensional HK parametric imaging, it was found that a WSL equal to 4 pulse lengths of the transducer was sufficient for estimating the <i><i>α</i></i> and <i>k</i> parameters in terms of both parameter estimation stability and parametric imaging resolution. The HK CWS parametric imaging provided an improved contrast-to-noise ratio over conventional HK parametric imaging, and the HK <i>α</i><sub>cws</sub> parametric imaging achieved the best accuracy and Dice score of coagulation zone detection.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346231162928\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346231162928","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

同动k (HK)分布是包络统计量的广义模型,其参数α(聚类参数)和k(相干弥散信号比)可以用来监测热损伤。在本研究中,我们提出了一种基于h扫描技术的超声HK对比度加权求和(CWS)参数成像算法,并通过仿真研究了XU估计器(一种基于强度的一阶矩和两个对数矩的估计方法)估计HK参数的最佳窗边长度(WSL)。h扫描将超声后向散射信号分散到低频段和高频频段。对各频段进行包络检测和HK参数估计,分别得到α和k参数图。根据目标区域与背景的对比,对双频带的(α或k)参数映射进行加权求和,然后通过伪彩色成像得到CWS图像。采用提出的HK CWS参数化成像算法检测不同功率和处理时间下猪肝离体微波消融凝血区。将该算法与传统HK参数成像、频率分集和复合Nakagami成像算法的性能进行了比较。对于二维HK参数成像,发现在参数估计稳定性和参数成像分辨率方面,等于换能器4个脉冲长度的WSL足以估计α和k参数。与传统HK参数成像相比,HK αcws参数成像具有更高的比噪比,并且HK αcws参数成像在凝血区检测上具有最佳的精度和Dice评分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones.

The homodyned-K (HK) distribution is a generalized model of envelope statistics whose parameters α (the clustering parameter) and k (the coherent-to-diffuse signal ratio) can be used to monitor the thermal lesions. In this study, we proposed an ultrasound HK contrast-weighted summation (CWS) parametric imaging algorithm based on the H-scan technique and investigated the optimal window side length (WSL) of the HK parameters estimated by the XU estimator (an estimation method based on the first moment of the intensity and two log-moments, which was used in the proposed algorithm) through phantom simulations. H-scan diversified ultrasonic backscattered signals into low- and high-frequency passbands. After envelope detection and HK parameter estimation for each frequency band, the α and k parametric maps were obtained, respectively. According to the contrast between the target region and background, the (α or k) parametric maps of the dual-frequency band were weighted and summed, and then the CWS images were yielded by pseudo-color imaging. The proposed HK CWS parametric imaging algorithm was used to detect the microwave ablation coagulation zones of porcine liver ex vivo under different powers and treatment durations. The performance of the proposed algorithm was compared with that of the conventional HK parametric imaging and frequency diversity and compounding Nakagami imaging algorithms. For two-dimensional HK parametric imaging, it was found that a WSL equal to 4 pulse lengths of the transducer was sufficient for estimating the α and k parameters in terms of both parameter estimation stability and parametric imaging resolution. The HK CWS parametric imaging provided an improved contrast-to-noise ratio over conventional HK parametric imaging, and the HK αcws parametric imaging achieved the best accuracy and Dice score of coagulation zone detection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasonic Imaging
Ultrasonic Imaging 医学-工程:生物医学
CiteScore
5.10
自引率
8.70%
发文量
15
审稿时长
>12 weeks
期刊介绍: Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging
期刊最新文献
Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots. Automated Deep Learning-Based Finger Joint Segmentation in 3-D Ultrasound Images With Limited Dataset. CBAM-RIUnet: Breast Tumor Segmentation With Enhanced Breast Ultrasound and Test-Time Augmentation Deep learning Radiomics Based on Two-Dimensional Ultrasound for Predicting the Efficacy of Neoadjuvant Chemotherapy in Breast Cancer SPGAN Optimized by Piranha Foraging Optimization for Thyroid Nodule Classification in Ultrasound Images
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1