假肢插座接口力学测量的进展:技术、技术综述和20年更新。

IF 2.9 3区 医学 Q3 ENGINEERING, BIOMEDICAL Expert Review of Medical Devices Pub Date : 2023-07-01 Epub Date: 2023-08-14 DOI:10.1080/17434440.2023.2244418
Peyton R Young, Jacqueline S Hebert, Paul D Marasco, Jason P Carey, Jonathon S Schofield
{"title":"假肢插座接口力学测量的进展:技术、技术综述和20年更新。","authors":"Peyton R Young, Jacqueline S Hebert, Paul D Marasco, Jason P Carey, Jonathon S Schofield","doi":"10.1080/17434440.2023.2244418","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A key determinant of prosthesis use is the quality of fit of the prosthetic socket. The socket surrounds the residual limb and applies the appropriate force distribution to the soft tissues to maintain suspension, support, and stabilization as well as translate limb movement to prosthesis movement. The challenge in socket fabrication lays in achieving geometry that provides the appropriate force distribution at physiologically appropriate locations; a task dependent on the understanding of interface tissue-mechanics.</p><p><strong>Areas covered: </strong>In the last 20 years substantial advancements in sensor innovation and computational power have allowed researchers to quantify the socket-residual limb interface; this paper reviews prominent measurement and sensing techniques described in literature over this time frame. Advantages and short comings of each technique are discussed with a focus on translation to clinical environments.</p><p><strong>Expert opinion: </strong>Prosthetic sockets directly influence comfort, device use, user satisfaction, and tissue health. Advancements in instrumentation technology have unlocked the possibility of sophisticated measurement systems providing quantitative data that may work in tandem with a clinician's heuristic expertise during socket fabrication. If validated, many of the emerging sensing technologies could be implemented into a clinical setting to better characterize how patients interact with their device and help inform prosthesis fabrication and assessment techniques.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581694/pdf/","citationCount":"0","resultStr":"{\"title\":\"Advances in the measurement of prosthetic socket interface mechanics: a review of technology, techniques, and a 20-year update.\",\"authors\":\"Peyton R Young, Jacqueline S Hebert, Paul D Marasco, Jason P Carey, Jonathon S Schofield\",\"doi\":\"10.1080/17434440.2023.2244418\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>A key determinant of prosthesis use is the quality of fit of the prosthetic socket. The socket surrounds the residual limb and applies the appropriate force distribution to the soft tissues to maintain suspension, support, and stabilization as well as translate limb movement to prosthesis movement. The challenge in socket fabrication lays in achieving geometry that provides the appropriate force distribution at physiologically appropriate locations; a task dependent on the understanding of interface tissue-mechanics.</p><p><strong>Areas covered: </strong>In the last 20 years substantial advancements in sensor innovation and computational power have allowed researchers to quantify the socket-residual limb interface; this paper reviews prominent measurement and sensing techniques described in literature over this time frame. Advantages and short comings of each technique are discussed with a focus on translation to clinical environments.</p><p><strong>Expert opinion: </strong>Prosthetic sockets directly influence comfort, device use, user satisfaction, and tissue health. Advancements in instrumentation technology have unlocked the possibility of sophisticated measurement systems providing quantitative data that may work in tandem with a clinician's heuristic expertise during socket fabrication. If validated, many of the emerging sensing technologies could be implemented into a clinical setting to better characterize how patients interact with their device and help inform prosthesis fabrication and assessment techniques.</p>\",\"PeriodicalId\":12330,\"journal\":{\"name\":\"Expert Review of Medical Devices\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581694/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Medical Devices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2023.2244418\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2244418","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

引言:假体使用的一个关键决定因素是假体窝的配合质量。承窝围绕残肢,并向软组织施加适当的力分布,以保持悬吊、支撑和稳定,并将肢体运动转化为假体运动。插座制造中的挑战在于实现在生理上适当的位置提供适当的力分布的几何形状;这项任务取决于对界面组织力学的理解。涵盖的领域:在过去20年中 多年来,传感器创新和计算能力的巨大进步使研究人员能够量化插座残肢界面;本文回顾了这段时间内文献中描述的重要测量和传感技术。讨论了每种技术的优点和缺点,重点是翻译到临床环境。专家意见:假肢插座直接影响舒适度、器械使用、用户满意度和组织健康。仪器技术的进步开启了复杂测量系统提供定量数据的可能性,这些数据可以在插座制造过程中与临床医生的启发式专业知识协同工作。如果得到验证,许多新兴的传感技术可以应用到临床环境中,以更好地描述患者如何与设备交互,并有助于为假体制造和评估技术提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Advances in the measurement of prosthetic socket interface mechanics: a review of technology, techniques, and a 20-year update.

Introduction: A key determinant of prosthesis use is the quality of fit of the prosthetic socket. The socket surrounds the residual limb and applies the appropriate force distribution to the soft tissues to maintain suspension, support, and stabilization as well as translate limb movement to prosthesis movement. The challenge in socket fabrication lays in achieving geometry that provides the appropriate force distribution at physiologically appropriate locations; a task dependent on the understanding of interface tissue-mechanics.

Areas covered: In the last 20 years substantial advancements in sensor innovation and computational power have allowed researchers to quantify the socket-residual limb interface; this paper reviews prominent measurement and sensing techniques described in literature over this time frame. Advantages and short comings of each technique are discussed with a focus on translation to clinical environments.

Expert opinion: Prosthetic sockets directly influence comfort, device use, user satisfaction, and tissue health. Advancements in instrumentation technology have unlocked the possibility of sophisticated measurement systems providing quantitative data that may work in tandem with a clinician's heuristic expertise during socket fabrication. If validated, many of the emerging sensing technologies could be implemented into a clinical setting to better characterize how patients interact with their device and help inform prosthesis fabrication and assessment techniques.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Expert Review of Medical Devices
Expert Review of Medical Devices 医学-工程:生物医学
CiteScore
5.90
自引率
3.20%
发文量
69
审稿时长
6-12 weeks
期刊介绍: The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections: Expert commentary - a personal view on the most effective or promising strategies Five-year view - a clear perspective of future prospects within a realistic timescale Key issues - an executive summary cutting to the author''s most critical points In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.
期刊最新文献
Future perspectives and challenges of artificial intelligence implementation in remote monitoring of cardiac implantable electronic devices. His bundle pacing combined with atrioventricular node ablation for atrial fibrillation: a systematic review and meta-analysis. Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database. Thoracic impedance monitoring in heart failure: from theory to practice. Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1