六角形和星形种植基牙螺钉头连续拧紧和松动后的变形评价。

Tahereh Ghaffari, Amin Nourizadeh, Elnaz Shafiei, Shima Ghasemi, Mohammadhasan Mahmoudzadeh, Kosar Ataei
{"title":"六角形和星形种植基牙螺钉头连续拧紧和松动后的变形评价。","authors":"Tahereh Ghaffari,&nbsp;Amin Nourizadeh,&nbsp;Elnaz Shafiei,&nbsp;Shima Ghasemi,&nbsp;Mohammadhasan Mahmoudzadeh,&nbsp;Kosar Ataei","doi":"10.34172/japid.2023.001","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Tightening and loosening of the prosthetic components of the implant are carried out with various screw designs. This study compared the rate of deformation of the abutment screw in two hexagonal and star screw head designs after consecutive tightening and loosening.</p><p><strong>Methods: </strong>In this study, two fixtures were mounted vertically in die stone blocks using a surveyor. Then the corresponding abutment (with a diameter of 4.5 mm and a gingival height of 2 mm; Dio-SM and Dio-UF system) was mounted on each fixture. In each fixture, six abutment screws from each manufacturer were used (12 abutment screws in total). The abutment screw head of the Dio-UF system is hexagonal, and the abutment screw head of the Dio-SM system is star-shaped. The samples were examined under a stereomicroscope (Nikon C-DS) at a magnification of×50. The image of each abutment screw head (6 abutment screws in each group) was prepared before the procedural steps and after 5, 10, and 15 times of tightening and loosening with 25-Ncm torque using a stereomicroscope. Then the differences in the surface areas of consecutive specimens (0, 5, 10, and 15 consecutive tightening and loosening rounds) between hexagonal and star-shaped abutment screws were calculated. The study results were reported via descriptive statistical methods (mean±standard deviation). Statistical analysis was performed using SPSS 24, and the significance level was defined at <i>P</i><0.05.</p><p><strong>Results: </strong>Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star shapes. At all stages, the changes in the star-shaped screw head were greater than in the hexagonal screw. These changes were statistically significant at all stages (<i>P</i><0.05). In addition, there was a statistically significant difference between the area values and the number of tightening and loosening rounds separately in both screw types (<i>P</i><0.001). Also, the surface areas of the head of both screws in all tightening and loosening rounds were significantly different (<i>P</i><0.001).</p><p><strong>Conclusion: </strong>Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star-shaped geometrical forms. Also, the extent of area changes at all stages in star-shaped screw heads was greater than in hexagonal screws.</p>","PeriodicalId":73584,"journal":{"name":"Journal of advanced periodontology & implant dentistry","volume":"15 1","pages":"60-63"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460774/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of implant abutment screw head deformation in hexagonal and star designs after successive tightening and loosening.\",\"authors\":\"Tahereh Ghaffari,&nbsp;Amin Nourizadeh,&nbsp;Elnaz Shafiei,&nbsp;Shima Ghasemi,&nbsp;Mohammadhasan Mahmoudzadeh,&nbsp;Kosar Ataei\",\"doi\":\"10.34172/japid.2023.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Tightening and loosening of the prosthetic components of the implant are carried out with various screw designs. This study compared the rate of deformation of the abutment screw in two hexagonal and star screw head designs after consecutive tightening and loosening.</p><p><strong>Methods: </strong>In this study, two fixtures were mounted vertically in die stone blocks using a surveyor. Then the corresponding abutment (with a diameter of 4.5 mm and a gingival height of 2 mm; Dio-SM and Dio-UF system) was mounted on each fixture. In each fixture, six abutment screws from each manufacturer were used (12 abutment screws in total). The abutment screw head of the Dio-UF system is hexagonal, and the abutment screw head of the Dio-SM system is star-shaped. The samples were examined under a stereomicroscope (Nikon C-DS) at a magnification of×50. The image of each abutment screw head (6 abutment screws in each group) was prepared before the procedural steps and after 5, 10, and 15 times of tightening and loosening with 25-Ncm torque using a stereomicroscope. Then the differences in the surface areas of consecutive specimens (0, 5, 10, and 15 consecutive tightening and loosening rounds) between hexagonal and star-shaped abutment screws were calculated. The study results were reported via descriptive statistical methods (mean±standard deviation). Statistical analysis was performed using SPSS 24, and the significance level was defined at <i>P</i><0.05.</p><p><strong>Results: </strong>Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star shapes. At all stages, the changes in the star-shaped screw head were greater than in the hexagonal screw. These changes were statistically significant at all stages (<i>P</i><0.05). In addition, there was a statistically significant difference between the area values and the number of tightening and loosening rounds separately in both screw types (<i>P</i><0.001). Also, the surface areas of the head of both screws in all tightening and loosening rounds were significantly different (<i>P</i><0.001).</p><p><strong>Conclusion: </strong>Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star-shaped geometrical forms. Also, the extent of area changes at all stages in star-shaped screw heads was greater than in hexagonal screws.</p>\",\"PeriodicalId\":73584,\"journal\":{\"name\":\"Journal of advanced periodontology & implant dentistry\",\"volume\":\"15 1\",\"pages\":\"60-63\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10460774/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of advanced periodontology & implant dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/japid.2023.001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of advanced periodontology & implant dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/japid.2023.001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:种植体的假体部件的拧紧和松动是通过各种螺钉设计进行的。本研究比较了六角形螺钉和星形螺钉头两种设计的基牙螺钉连续拧紧和松动后的变形速率。方法:在本研究中,使用测量器将两个夹具垂直安装在模具石块中。然后是相应的基牙(直径4.5 mm,牙龈高度2 mm;在每个夹具上安装Dio-SM和Dio-UF系统。在每个夹具中,每个制造商使用6个基台螺钉(总共12个基台螺钉)。迪奥- uf系统的基台螺钉头为六角形,迪奥- sm系统的基台螺钉头为星形。样品在体视显微镜(尼康C-DS)下进行检查,放大of×50。每个基牙螺钉头(每组6个基牙螺钉)在操作步骤前和以25-Ncm扭矩拧紧、松动5次、10次、15次后在体视显微镜下成像。然后计算六角形和星形基台螺钉连续试件(0、5、10、15轮连续拧紧和松动)的表面积差异。研究结果采用描述性统计方法(均数±标准差)报道。使用SPSS 24进行统计分析,显著性水平定义为:结果:增加拧紧和松动轮数增加了六边形和星形螺钉头表面积。在各阶段,星形螺钉头的变化均大于六角形螺钉。结论:增加拧紧和松动的次数增加了螺钉头六角形和星形几何形状的表面积。星形螺钉头各阶段的面积变化程度均大于六角形螺钉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of implant abutment screw head deformation in hexagonal and star designs after successive tightening and loosening.

Background: Tightening and loosening of the prosthetic components of the implant are carried out with various screw designs. This study compared the rate of deformation of the abutment screw in two hexagonal and star screw head designs after consecutive tightening and loosening.

Methods: In this study, two fixtures were mounted vertically in die stone blocks using a surveyor. Then the corresponding abutment (with a diameter of 4.5 mm and a gingival height of 2 mm; Dio-SM and Dio-UF system) was mounted on each fixture. In each fixture, six abutment screws from each manufacturer were used (12 abutment screws in total). The abutment screw head of the Dio-UF system is hexagonal, and the abutment screw head of the Dio-SM system is star-shaped. The samples were examined under a stereomicroscope (Nikon C-DS) at a magnification of×50. The image of each abutment screw head (6 abutment screws in each group) was prepared before the procedural steps and after 5, 10, and 15 times of tightening and loosening with 25-Ncm torque using a stereomicroscope. Then the differences in the surface areas of consecutive specimens (0, 5, 10, and 15 consecutive tightening and loosening rounds) between hexagonal and star-shaped abutment screws were calculated. The study results were reported via descriptive statistical methods (mean±standard deviation). Statistical analysis was performed using SPSS 24, and the significance level was defined at P<0.05.

Results: Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star shapes. At all stages, the changes in the star-shaped screw head were greater than in the hexagonal screw. These changes were statistically significant at all stages (P<0.05). In addition, there was a statistically significant difference between the area values and the number of tightening and loosening rounds separately in both screw types (P<0.001). Also, the surface areas of the head of both screws in all tightening and loosening rounds were significantly different (P<0.001).

Conclusion: Increasing the number of tightening and loosening rounds increased the screw head surface area in both hexagonal and star-shaped geometrical forms. Also, the extent of area changes at all stages in star-shaped screw heads was greater than in hexagonal screws.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
0
审稿时长
20 weeks
期刊最新文献
Deep margin elevation; Indications and periodontal considerations. Effect of orthodontic forced eruption for implant site development in the maxillary esthetic zone: A systematic review of clinical data. Beneficial effects of cranberry juice enriched with omega-3 fatty acids in patients with type 2 diabetic and periodontal disease: A randomized pilot clinical trial. Comparison of the effect of albumin with platelet-rich fibrin (Alb-PRF) gel and hyaluronic acid gel injection on interdental papilla reconstruction: A randomized clinical trial. Effect of atorvastatin gel in non-surgical treatment of peri-implant mucositis: A randomized controlled clinical trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1