Néstor J Oviedo, Cindy L Nicolas, Dany S Adams, Michael Levin
{"title":"利用 DiBAC4(3) 对鳞片膜电位进行实时成像。","authors":"Néstor J Oviedo, Cindy L Nicolas, Dany S Adams, Michael Levin","doi":"10.1101/pdb.prot5055","DOIUrl":null,"url":null,"abstract":"<p><p>INTRODUCTIONThis protocol describes how to use the anionic membrane voltage-reporting dye DiBAC(4)(3) to generate images of cell membrane potential in live planarians. These images qualitatively reveal variations in time-averaged membrane potential across different regions of the organism. Changes in these images due to experimental treatments reveal how the particular treatment affects this physiological parameter. This method is a great improvement over standard electrophysiological techniques, which cannot be used to gain an understanding of the electrical properties of an entire worm or a regenerating fragment, due to small cell size and large cell number. When the proper controls are performed, this technique is a very powerful and simple way to gather physiologic data.</p>","PeriodicalId":10835,"journal":{"name":"CSH protocols","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468776/pdf/nihms-1925437.pdf","citationCount":"0","resultStr":"{\"title\":\"Live Imaging of Planarian Membrane Potential Using DiBAC4(3).\",\"authors\":\"Néstor J Oviedo, Cindy L Nicolas, Dany S Adams, Michael Levin\",\"doi\":\"10.1101/pdb.prot5055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>INTRODUCTIONThis protocol describes how to use the anionic membrane voltage-reporting dye DiBAC(4)(3) to generate images of cell membrane potential in live planarians. These images qualitatively reveal variations in time-averaged membrane potential across different regions of the organism. Changes in these images due to experimental treatments reveal how the particular treatment affects this physiological parameter. This method is a great improvement over standard electrophysiological techniques, which cannot be used to gain an understanding of the electrical properties of an entire worm or a regenerating fragment, due to small cell size and large cell number. When the proper controls are performed, this technique is a very powerful and simple way to gather physiologic data.</p>\",\"PeriodicalId\":10835,\"journal\":{\"name\":\"CSH protocols\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468776/pdf/nihms-1925437.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CSH protocols\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1101/pdb.prot5055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CSH protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/pdb.prot5055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Live Imaging of Planarian Membrane Potential Using DiBAC4(3).
INTRODUCTIONThis protocol describes how to use the anionic membrane voltage-reporting dye DiBAC(4)(3) to generate images of cell membrane potential in live planarians. These images qualitatively reveal variations in time-averaged membrane potential across different regions of the organism. Changes in these images due to experimental treatments reveal how the particular treatment affects this physiological parameter. This method is a great improvement over standard electrophysiological techniques, which cannot be used to gain an understanding of the electrical properties of an entire worm or a regenerating fragment, due to small cell size and large cell number. When the proper controls are performed, this technique is a very powerful and simple way to gather physiologic data.