接头形态对常规与半透明氧化锆三单元固定修复体断裂载荷的影响。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2023-08-01 DOI:10.4047/jap.2023.15.4.171
Chonticha Subsomboon, Somchai Urapepon
{"title":"接头形态对常规与半透明氧化锆三单元固定修复体断裂载荷的影响。","authors":"Chonticha Subsomboon,&nbsp;Somchai Urapepon","doi":"10.4047/jap.2023.15.4.171","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs).</p><p><strong>Materials and methods: </strong>Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML<sup>®</sup>), 4Y-TZP (Katana STML<sup>®</sup>), and 5Y-TZP (Katana UTML<sup>®</sup>)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The Co-Cr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05).</p><p><strong>Results: </strong>Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (<i>P</i> < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (<i>P</i> > .05). The connector configuration within 9 mm<sup>2</sup> was found to have no effect on the fracture loads on all three types of zirconia (<i>P</i> > .05).</p><p><strong>Conclusion: </strong>Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm<sup>2</sup>.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/9b/jap-15-171.PMC10471503.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses.\",\"authors\":\"Chonticha Subsomboon,&nbsp;Somchai Urapepon\",\"doi\":\"10.4047/jap.2023.15.4.171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs).</p><p><strong>Materials and methods: </strong>Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML<sup>®</sup>), 4Y-TZP (Katana STML<sup>®</sup>), and 5Y-TZP (Katana UTML<sup>®</sup>)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The Co-Cr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05).</p><p><strong>Results: </strong>Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (<i>P</i> < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (<i>P</i> > .05). The connector configuration within 9 mm<sup>2</sup> was found to have no effect on the fracture loads on all three types of zirconia (<i>P</i> > .05).</p><p><strong>Conclusion: </strong>Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm<sup>2</sup>.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/9b/jap-15-171.PMC10471503.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2023.15.4.171\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2023.15.4.171","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是确定三单元固定义齿(FDPs)在常规氧化锆和半透明氧化锆中接头结构对断裂载荷的影响。材料和方法:采用3种氧化锆(3Y-TZP (Katana ML®)、4Y-TZP (Katana STML®)和5Y-TZP (Katana UTML®)),结合2种连接器配置(4 × 2.25, 3 × 3mm)制备6种不同的3单元fdp (n = 6)。扫描Co-Cr主模型,利用CAD-CAM对fdp进行设计和制作。将fdp粘合在金属模型上,然后以1 mm/min的十字头速度加载UTM,直到失效。采用双因素方差分析和Tukey’s检验进行统计学分析(α = 0.05)。结果:3Y-TZP的骨折载荷(4 × 2.25 mm和3 × 3 mm分别为2740.6±469.2和2718.7±339.0 N)明显高于4Y-TZP(分别为1868.3±281.6和1663.6±372.7 N)和5Y-TZP(分别为1588.0±255.0和1559.1±110.0 N) (P < 0.05)。4Y-TZP与5Y-TZP骨折负荷无显著差异(P > 0.05)。在9 mm2范围内的连接器配置对三种氧化锆的断裂载荷没有影响(P > 0.05)。结论:三单元fdp的断裂载荷受氧化锆类型的影响。常规氧化锆的断裂载荷高于半透明氧化锆。然而,当连接器的横截面积为9 mm2时,它不受连接器配置的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses.

Purpose: The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs).

Materials and methods: Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML®), 4Y-TZP (Katana STML®), and 5Y-TZP (Katana UTML®)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The Co-Cr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05).

Results: Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (P < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (P > .05). The connector configuration within 9 mm2 was found to have no effect on the fracture loads on all three types of zirconia (P > .05).

Conclusion: Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A novel brief questionnaire using a face rating scale to assess dental anxiety and fear. Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis. Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis. Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study. Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software's multi-occlusion function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1