一个带注释的室性心动过速(VT)报警数据库:为优化住院患者VT自动识别提供统一标准

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Annals of Noninvasive Electrocardiology Pub Date : 2023-03-09 DOI:10.1111/anec.13054
Michele M. Pelter RN, PhD, Mary G. Carey RN, PhD, Salah Al-Zaiti RN, PhD, Jessica Zegre-Hemsey RN, PhD, Claire Sommargren RN, PhD, Lamberto Isola MS, Priya Prasad PhD, David Mortara PhD, Fabio Badilini PhD
{"title":"一个带注释的室性心动过速(VT)报警数据库:为优化住院患者VT自动识别提供统一标准","authors":"Michele M. Pelter RN, PhD,&nbsp;Mary G. Carey RN, PhD,&nbsp;Salah Al-Zaiti RN, PhD,&nbsp;Jessica Zegre-Hemsey RN, PhD,&nbsp;Claire Sommargren RN, PhD,&nbsp;Lamberto Isola MS,&nbsp;Priya Prasad PhD,&nbsp;David Mortara PhD,&nbsp;Fabio Badilini PhD","doi":"10.1111/anec.13054","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>False ventricular tachycardia (VT) alarms are common during in-hospital electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT can be attributed to algorithm deficiencies.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The purpose of this study was: (1) to describe the creation of a VT database annotated by ECG experts and (2) to determine true vs. false VT using a new VT algorithm created by our group.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The VT algorithm was processed in 5320 consecutive ICU patients with 572,574 h of ECG and physiologic monitoring. A search algorithm identified potential VT, defined as: heart rate &gt;100 beats/min, QRSs &gt; 120 ms, and change in QRS morphology in &gt;6 consecutive beats compared to the preceding native rhythm. Seven ECG channels, SpO<sub>2</sub>, and arterial blood pressure waveforms were processed and loaded into a web-based annotation software program. Five PhD-prepared nurse scientists performed the annotations.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Of the 5320 ICU patients, 858 (16.13%) had 22,325 VTs. After three levels of iterative annotations, a total of 11,970 (53.62%) were adjudicated as true, 6485 (29.05%) as false, and 3870 (17.33%) were unresolved. The unresolved VTs were concentrated in 17 patients (1.98%). Of the 3870 unresolved VTs, 85.7% (<i>n</i> = 3281) were confounded by ventricular paced rhythm, 10.8% (<i>n</i> = 414) by underlying BBB, and 3.5% (<i>n</i> = 133) had a combination of both.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The database described here represents the single largest human-annotated database to date. The database includes consecutive ICU patients, with true, false, and challenging VTs (unresolved) and could serve as a gold standard database to develop and test new VT algorithms.</p>\n </section>\n </div>","PeriodicalId":8074,"journal":{"name":"Annals of Noninvasive Electrocardiology","volume":"28 4","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/46/9c/ANEC-28-e13054.PMC10335615.pdf","citationCount":"4","resultStr":"{\"title\":\"An annotated ventricular tachycardia (VT) alarm database: Toward a uniform standard for optimizing automated VT identification in hospitalized patients\",\"authors\":\"Michele M. Pelter RN, PhD,&nbsp;Mary G. Carey RN, PhD,&nbsp;Salah Al-Zaiti RN, PhD,&nbsp;Jessica Zegre-Hemsey RN, PhD,&nbsp;Claire Sommargren RN, PhD,&nbsp;Lamberto Isola MS,&nbsp;Priya Prasad PhD,&nbsp;David Mortara PhD,&nbsp;Fabio Badilini PhD\",\"doi\":\"10.1111/anec.13054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>False ventricular tachycardia (VT) alarms are common during in-hospital electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT can be attributed to algorithm deficiencies.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>The purpose of this study was: (1) to describe the creation of a VT database annotated by ECG experts and (2) to determine true vs. false VT using a new VT algorithm created by our group.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The VT algorithm was processed in 5320 consecutive ICU patients with 572,574 h of ECG and physiologic monitoring. A search algorithm identified potential VT, defined as: heart rate &gt;100 beats/min, QRSs &gt; 120 ms, and change in QRS morphology in &gt;6 consecutive beats compared to the preceding native rhythm. Seven ECG channels, SpO<sub>2</sub>, and arterial blood pressure waveforms were processed and loaded into a web-based annotation software program. Five PhD-prepared nurse scientists performed the annotations.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Of the 5320 ICU patients, 858 (16.13%) had 22,325 VTs. After three levels of iterative annotations, a total of 11,970 (53.62%) were adjudicated as true, 6485 (29.05%) as false, and 3870 (17.33%) were unresolved. The unresolved VTs were concentrated in 17 patients (1.98%). Of the 3870 unresolved VTs, 85.7% (<i>n</i> = 3281) were confounded by ventricular paced rhythm, 10.8% (<i>n</i> = 414) by underlying BBB, and 3.5% (<i>n</i> = 133) had a combination of both.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The database described here represents the single largest human-annotated database to date. The database includes consecutive ICU patients, with true, false, and challenging VTs (unresolved) and could serve as a gold standard database to develop and test new VT algorithms.</p>\\n </section>\\n </div>\",\"PeriodicalId\":8074,\"journal\":{\"name\":\"Annals of Noninvasive Electrocardiology\",\"volume\":\"28 4\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-03-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/46/9c/ANEC-28-e13054.PMC10335615.pdf\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Noninvasive Electrocardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/anec.13054\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Noninvasive Electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/anec.13054","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 4

摘要

背景:假室性心动过速(VT)警报在医院心电图(ECG)监测中很常见。先前的研究表明,大多数假VT可归因于算法缺陷。本研究的目的是:(1)描述由ECG专家注释的VT数据库的创建;(2)使用我们小组创建的新的VT算法来确定真假VT。方法对5320例连续进行572,574 h心电图和生理监测的ICU患者进行VT算法处理。一个搜索算法确定了潜在VT,定义为:心率>100次/分,QRSs > 120毫秒,以及连续6次与之前的自然节奏相比QRS形态学的变化。七个ECG通道、SpO2和动脉血压波形被处理并加载到基于web的注释软件程序中。五名博士学位的护士科学家进行了注释。结果5320例ICU患者中,858例(16.13%)有22,325例静脉血栓。经过三级迭代标注,共判定真题11,970份(53.62%),假题6485份(29.05%),未解决题3870份(17.33%)。未解决的静脉血栓集中在17例(1.98%)。在3870例未解决的室性心动过速中,85.7% (n = 3281)与室性心律混淆,10.8% (n = 414)与潜在血脑屏障混淆,3.5% (n = 133)两者兼有。这里描述的数据库是迄今为止最大的人工注释数据库。该数据库包括连续的ICU患者,真实、虚假和具有挑战性的VT(未解决),可以作为开发和测试新的VT算法的金标准数据库。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An annotated ventricular tachycardia (VT) alarm database: Toward a uniform standard for optimizing automated VT identification in hospitalized patients

Background

False ventricular tachycardia (VT) alarms are common during in-hospital electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT can be attributed to algorithm deficiencies.

Purpose

The purpose of this study was: (1) to describe the creation of a VT database annotated by ECG experts and (2) to determine true vs. false VT using a new VT algorithm created by our group.

Methods

The VT algorithm was processed in 5320 consecutive ICU patients with 572,574 h of ECG and physiologic monitoring. A search algorithm identified potential VT, defined as: heart rate >100 beats/min, QRSs > 120 ms, and change in QRS morphology in >6 consecutive beats compared to the preceding native rhythm. Seven ECG channels, SpO2, and arterial blood pressure waveforms were processed and loaded into a web-based annotation software program. Five PhD-prepared nurse scientists performed the annotations.

Results

Of the 5320 ICU patients, 858 (16.13%) had 22,325 VTs. After three levels of iterative annotations, a total of 11,970 (53.62%) were adjudicated as true, 6485 (29.05%) as false, and 3870 (17.33%) were unresolved. The unresolved VTs were concentrated in 17 patients (1.98%). Of the 3870 unresolved VTs, 85.7% (n = 3281) were confounded by ventricular paced rhythm, 10.8% (n = 414) by underlying BBB, and 3.5% (n = 133) had a combination of both.

Conclusions

The database described here represents the single largest human-annotated database to date. The database includes consecutive ICU patients, with true, false, and challenging VTs (unresolved) and could serve as a gold standard database to develop and test new VT algorithms.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
0.00%
发文量
88
审稿时长
6-12 weeks
期刊介绍: The ANNALS OF NONINVASIVE ELECTROCARDIOLOGY (A.N.E) is an online only journal that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients. ANE is the first journal in an evolving subspecialty that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients. The publication includes topics related to 12-lead, exercise and high-resolution electrocardiography, arrhythmias, ischemia, repolarization phenomena, heart rate variability, circadian rhythms, bioengineering technology, signal-averaged ECGs, T-wave alternans and automatic external defibrillation. ANE publishes peer-reviewed articles of interest to clinicians and researchers in the field of noninvasive electrocardiology. Original research, clinical studies, state-of-the-art reviews, case reports, technical notes, and letters to the editors will be published to meet future demands in this field.
期刊最新文献
Predictors of Myocardial Fibrosis Detected by CMR in Patients With Idiopathic PVCs Catheter Ablation of Ventricular Premature Contractions Originating From RVOT With Interruption of the Inferior Vena Cava—A Case Report Association Between Different Insulin Resistance Indices and Heart Failure in US Adults With Diabetes Mellitus Coronary Angiographic Features of de Winter Syndrome: More Than Just Occlusion of the Left Anterior Descending Artery Intracardiac Echocardiography and Ablation of Atrial Fibrillation in Dextrocardia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1