John Kenneth Leypoldt, Mauro Pietribiasi, Malgorzata Debowska, Monika Wieliczko, Malgorzata Twardowska-Kawalec, Jolanta Malyszko, Jacek Waniewski
{"title":"血液透析过程中氢离子动员模型与时间依赖性透析液碳酸氢盐浓度的有效性。","authors":"John Kenneth Leypoldt, Mauro Pietribiasi, Malgorzata Debowska, Monika Wieliczko, Malgorzata Twardowska-Kawalec, Jolanta Malyszko, Jacek Waniewski","doi":"10.1177/03913988231179233","DOIUrl":null,"url":null,"abstract":"Background: The hydrogen ion (H+) mobilisation model has been previously shown to accurately describe blood bicarbonate (HCO3) kinetics during haemodialysis (HD) when the dialysate bicarbonate concentration ([HCO3]) is constant throughout the treatment. This study evaluated the ability of the H+ mobilization model to describe blood HCO3 kinetics during HD treatments with a time-dependent dialysate [HCO3]. Methods: Data from a recent clinical study where blood [HCO3] was measured at the beginning of and every hour during 4-h treatments in 20 chronic, thrice-weekly HD patients with a constant (Treatment A), decreasing (Treatment B) and increasing (Treatment C) dialysate [HCO3] were evaluated. The H+ mobilization model was used to determine the model parameter (Hm) that provided the best fit of the model to the clinical data using nonlinear regression. A total of 114 HD treatments provided individual estimates of Hm. Results: Mean ± standard deviation estimates of Hm during Treatments A, B and C were 0.153 ± 0.069, 0.180 ± 0.109 and 0.205 ± 0.141 L/min (medians [interquartile ranges] were 0.145 [0.118,0.191], 0.159 [0.112,0.209], 0.169 [0.115,0.236] L/min), respectively; these estimates were not different from each other (p = 0.26). The sum of squared differences between the measured blood [HCO3] and that predicted by the model were not different during Treatments A, B and C (p = 0.50), suggesting a similar degree of model fit to the data. Conclusions: This study supports the validity of the H+ mobilization model to describe intradialysis blood HCO3 kinetics during HD with a constant Hm value when using a time-dependent dialysate [HCO3].","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":"46 8-9","pages":"507-513"},"PeriodicalIF":1.3000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validity of the hydrogen ion mobilisation model during haemodialysis with time-dependent dialysate bicarbonate concentrations.\",\"authors\":\"John Kenneth Leypoldt, Mauro Pietribiasi, Malgorzata Debowska, Monika Wieliczko, Malgorzata Twardowska-Kawalec, Jolanta Malyszko, Jacek Waniewski\",\"doi\":\"10.1177/03913988231179233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The hydrogen ion (H+) mobilisation model has been previously shown to accurately describe blood bicarbonate (HCO3) kinetics during haemodialysis (HD) when the dialysate bicarbonate concentration ([HCO3]) is constant throughout the treatment. This study evaluated the ability of the H+ mobilization model to describe blood HCO3 kinetics during HD treatments with a time-dependent dialysate [HCO3]. Methods: Data from a recent clinical study where blood [HCO3] was measured at the beginning of and every hour during 4-h treatments in 20 chronic, thrice-weekly HD patients with a constant (Treatment A), decreasing (Treatment B) and increasing (Treatment C) dialysate [HCO3] were evaluated. The H+ mobilization model was used to determine the model parameter (Hm) that provided the best fit of the model to the clinical data using nonlinear regression. A total of 114 HD treatments provided individual estimates of Hm. Results: Mean ± standard deviation estimates of Hm during Treatments A, B and C were 0.153 ± 0.069, 0.180 ± 0.109 and 0.205 ± 0.141 L/min (medians [interquartile ranges] were 0.145 [0.118,0.191], 0.159 [0.112,0.209], 0.169 [0.115,0.236] L/min), respectively; these estimates were not different from each other (p = 0.26). The sum of squared differences between the measured blood [HCO3] and that predicted by the model were not different during Treatments A, B and C (p = 0.50), suggesting a similar degree of model fit to the data. Conclusions: This study supports the validity of the H+ mobilization model to describe intradialysis blood HCO3 kinetics during HD with a constant Hm value when using a time-dependent dialysate [HCO3].\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":\"46 8-9\",\"pages\":\"507-513\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988231179233\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231179233","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Validity of the hydrogen ion mobilisation model during haemodialysis with time-dependent dialysate bicarbonate concentrations.
Background: The hydrogen ion (H+) mobilisation model has been previously shown to accurately describe blood bicarbonate (HCO3) kinetics during haemodialysis (HD) when the dialysate bicarbonate concentration ([HCO3]) is constant throughout the treatment. This study evaluated the ability of the H+ mobilization model to describe blood HCO3 kinetics during HD treatments with a time-dependent dialysate [HCO3]. Methods: Data from a recent clinical study where blood [HCO3] was measured at the beginning of and every hour during 4-h treatments in 20 chronic, thrice-weekly HD patients with a constant (Treatment A), decreasing (Treatment B) and increasing (Treatment C) dialysate [HCO3] were evaluated. The H+ mobilization model was used to determine the model parameter (Hm) that provided the best fit of the model to the clinical data using nonlinear regression. A total of 114 HD treatments provided individual estimates of Hm. Results: Mean ± standard deviation estimates of Hm during Treatments A, B and C were 0.153 ± 0.069, 0.180 ± 0.109 and 0.205 ± 0.141 L/min (medians [interquartile ranges] were 0.145 [0.118,0.191], 0.159 [0.112,0.209], 0.169 [0.115,0.236] L/min), respectively; these estimates were not different from each other (p = 0.26). The sum of squared differences between the measured blood [HCO3] and that predicted by the model were not different during Treatments A, B and C (p = 0.50), suggesting a similar degree of model fit to the data. Conclusions: This study supports the validity of the H+ mobilization model to describe intradialysis blood HCO3 kinetics during HD with a constant Hm value when using a time-dependent dialysate [HCO3].
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.