Aydogdy Serdarov, Banu Bozkurt, Yalçın Karaküçük, Süleyman Okudan
{"title":"混合隐形眼镜在圆锥角膜患者中的临床应用及患者满意度。","authors":"Aydogdy Serdarov, Banu Bozkurt, Yalçın Karaküçük, Süleyman Okudan","doi":"10.4274/tjo.galenos.2022.43077","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of the study was to evaluate the fitting process, clinical performance, and patient satisfaction of hybrid contact lenses (HCL) in patients with keratoconus (KC).</p><p><strong>Materials and methods: </strong>Sixty-eight KC patients (35 female, 33 male) who were prescribed HCL were included in the study. Corneal topographic parameters, best corrected visual acuity (BCVA) with eyeglasses, the number of HCL trials, prescribed HCL base curve (BC), and visual acuity with HCL were recorded from hospital records. A contact lens satisfaction survey was sent to the patients via email or WhatsApp and the data was statistically analyzed using IBM SPSS Statistics version 22.0.</p><p><strong>Results: </strong>The study included 110 eyes of 68 patients with a mean age of 27.34±8 years (range: 12-48 years). According to the Amsler-Krumeich classification, 35.5% of the eyes were stage 1, 50.9% were stage 2, and 13.5% were stage 3 or 4. Mean K1, K2, and Kmean values were 7.14±0.50 mm (range 5.72-8.30 mm), 6.63±0.49 mm (range 5.07-7.84 mm), and 6.89±0.48 mm (range 5.39-8.06 mm), respectively. The average number of lens trials was 1.59±0.82 (range 1-4). The mean BC of the prescribed HCL was 6.84±0.50 mm (range 5.60-8.00 mm). BCVA with glasses was 0.36±0.2 (range 0.05-0.8), and 0.80±0.14 (range 0.3-1.0) with HCL (p<0.0001). The overall survey score was 3.54 out of 5, the overall satisfaction score was 3.27, the average vision satisfaction score was 3.62, the average satisfaction score for lens insertion and removal was 3.01, and the average satisfaction score for lens comfort was 2.97.</p><p><strong>Conclusion: </strong>Prescribed HCL BC is usually close to the topographic K<sub>mean</sub> value and in most of the patients, fitting was successful with the first or second CL trial. The overall satisfaction score was moderate to good and the disadvantages were low comfort compared to soft CL, difficulty with insertion and removal, short lens life, and high cost.</p>","PeriodicalId":23373,"journal":{"name":"Turkish Journal of Ophthalmology","volume":"53 4","pages":"206-212"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/ed/TJO-53-206.PMC10442754.pdf","citationCount":"0","resultStr":"{\"title\":\"Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus.\",\"authors\":\"Aydogdy Serdarov, Banu Bozkurt, Yalçın Karaküçük, Süleyman Okudan\",\"doi\":\"10.4274/tjo.galenos.2022.43077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of the study was to evaluate the fitting process, clinical performance, and patient satisfaction of hybrid contact lenses (HCL) in patients with keratoconus (KC).</p><p><strong>Materials and methods: </strong>Sixty-eight KC patients (35 female, 33 male) who were prescribed HCL were included in the study. Corneal topographic parameters, best corrected visual acuity (BCVA) with eyeglasses, the number of HCL trials, prescribed HCL base curve (BC), and visual acuity with HCL were recorded from hospital records. A contact lens satisfaction survey was sent to the patients via email or WhatsApp and the data was statistically analyzed using IBM SPSS Statistics version 22.0.</p><p><strong>Results: </strong>The study included 110 eyes of 68 patients with a mean age of 27.34±8 years (range: 12-48 years). According to the Amsler-Krumeich classification, 35.5% of the eyes were stage 1, 50.9% were stage 2, and 13.5% were stage 3 or 4. Mean K1, K2, and Kmean values were 7.14±0.50 mm (range 5.72-8.30 mm), 6.63±0.49 mm (range 5.07-7.84 mm), and 6.89±0.48 mm (range 5.39-8.06 mm), respectively. The average number of lens trials was 1.59±0.82 (range 1-4). The mean BC of the prescribed HCL was 6.84±0.50 mm (range 5.60-8.00 mm). BCVA with glasses was 0.36±0.2 (range 0.05-0.8), and 0.80±0.14 (range 0.3-1.0) with HCL (p<0.0001). The overall survey score was 3.54 out of 5, the overall satisfaction score was 3.27, the average vision satisfaction score was 3.62, the average satisfaction score for lens insertion and removal was 3.01, and the average satisfaction score for lens comfort was 2.97.</p><p><strong>Conclusion: </strong>Prescribed HCL BC is usually close to the topographic K<sub>mean</sub> value and in most of the patients, fitting was successful with the first or second CL trial. The overall satisfaction score was moderate to good and the disadvantages were low comfort compared to soft CL, difficulty with insertion and removal, short lens life, and high cost.</p>\",\"PeriodicalId\":23373,\"journal\":{\"name\":\"Turkish Journal of Ophthalmology\",\"volume\":\"53 4\",\"pages\":\"206-212\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/ed/TJO-53-206.PMC10442754.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4274/tjo.galenos.2022.43077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tjo.galenos.2022.43077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
目的:本研究旨在评估混合型隐形眼镜(HCL)在圆锥角膜(KC)患者中的配戴过程、临床表现和患者满意度。材料与方法:68例KC患者(女性35例,男性33例)接受HCL处方。从医院记录角膜地形图参数、配戴眼镜的最佳矫正视力(BCVA)、HCL试验次数、处方HCL基线曲线(BC)和HCL患者的视力。通过邮件或WhatsApp向患者发送隐形眼镜满意度调查问卷,并使用IBM SPSS Statistics version 22.0对数据进行统计分析。结果:纳入患者68例,110只眼,平均年龄27.34±8岁(范围:12 ~ 48岁)。根据Amsler-Krumeich分类,35.5%的眼睛为1期,50.9%为2期,13.5%为3期或4期。K1、K2和Kmean的平均值分别为7.14±0.50 mm (5.72 ~ 8.30 mm)、6.63±0.49 mm (5.07 ~ 7.84 mm)和6.89±0.48 mm (5.39 ~ 8.06 mm)。平均晶状体试验次数为1.59±0.82次(范围1-4)。处方HCL的平均BC为6.84±0.50 mm(范围5.60-8.00 mm)。配戴眼镜的BCVA为0.36±0.2(范围0.05 ~ 0.8),配戴HCL的BCVA为0.80±0.14(范围0.3 ~ 1.0)。结论:处方HCL的BC通常接近地形Kmean值,大多数患者在第一次或第二次CL试验中吻合成功。总体满意度评分为中等至良好,缺点是与软晶体相比舒适度低,植入和取出困难,晶状体寿命短,成本高。
Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus.
Objectives: The aim of the study was to evaluate the fitting process, clinical performance, and patient satisfaction of hybrid contact lenses (HCL) in patients with keratoconus (KC).
Materials and methods: Sixty-eight KC patients (35 female, 33 male) who were prescribed HCL were included in the study. Corneal topographic parameters, best corrected visual acuity (BCVA) with eyeglasses, the number of HCL trials, prescribed HCL base curve (BC), and visual acuity with HCL were recorded from hospital records. A contact lens satisfaction survey was sent to the patients via email or WhatsApp and the data was statistically analyzed using IBM SPSS Statistics version 22.0.
Results: The study included 110 eyes of 68 patients with a mean age of 27.34±8 years (range: 12-48 years). According to the Amsler-Krumeich classification, 35.5% of the eyes were stage 1, 50.9% were stage 2, and 13.5% were stage 3 or 4. Mean K1, K2, and Kmean values were 7.14±0.50 mm (range 5.72-8.30 mm), 6.63±0.49 mm (range 5.07-7.84 mm), and 6.89±0.48 mm (range 5.39-8.06 mm), respectively. The average number of lens trials was 1.59±0.82 (range 1-4). The mean BC of the prescribed HCL was 6.84±0.50 mm (range 5.60-8.00 mm). BCVA with glasses was 0.36±0.2 (range 0.05-0.8), and 0.80±0.14 (range 0.3-1.0) with HCL (p<0.0001). The overall survey score was 3.54 out of 5, the overall satisfaction score was 3.27, the average vision satisfaction score was 3.62, the average satisfaction score for lens insertion and removal was 3.01, and the average satisfaction score for lens comfort was 2.97.
Conclusion: Prescribed HCL BC is usually close to the topographic Kmean value and in most of the patients, fitting was successful with the first or second CL trial. The overall satisfaction score was moderate to good and the disadvantages were low comfort compared to soft CL, difficulty with insertion and removal, short lens life, and high cost.
期刊介绍:
The Turkish Journal of Ophthalmology (TJO) is the only scientific periodical publication of the Turkish Ophthalmological Association and has been published since January 1929. In its early years, the journal was published in Turkish and French. Although there were temporary interruptions in the publication of the journal due to various challenges, the Turkish Journal of Ophthalmology has been published continually from 1971 to the present. The target audience includes specialists and physicians in training in ophthalmology in all relevant disciplines.