颞下颌关节外侧髁囊距离单次超声波测量的观察者内部可靠性和有效性。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Ultrasound Pub Date : 2024-09-01 Epub Date: 2023-09-01 DOI:10.1007/s40477-023-00818-z
Raquel Delgado-Delgado, Orlando Conde-Vázquez, Fiona Mc Fall, Tomás Fernández-Rodríguez
{"title":"颞下颌关节外侧髁囊距离单次超声波测量的观察者内部可靠性和有效性。","authors":"Raquel Delgado-Delgado, Orlando Conde-Vázquez, Fiona Mc Fall, Tomás Fernández-Rodríguez","doi":"10.1007/s40477-023-00818-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study was to examine the reliability and validity of a single lateral condyle-capsule distance (LCCD) measurement while saving on economic costs and clinical resources.</p><p><strong>Methods: </strong>A longitudinal test-retest design was used to assess the reliability and validity of single-examiner measures over 72 TMJ sonographic analyses. Intraclass correlation coefficients (ICC) and a Bland-Altman plot were used to study reliability and validity, comparing the first measurement of the LCCD to the mean of 3 measurements taken one week later by the same examiner.</p><p><strong>Results: </strong>ICC show intraobserver reliability of 0.981, 95% confidence intervals (CI) of 0.969 to 0.988. The mean difference between the ultrasound measurements is 0.019 mm (95% CI 0.0005-0.0383) with a standard deviation of 0.080 mm, demonstrating robust validity. The 95% Limits of Agreement (LoA) are - 0.138 for the lower limit and 0.177 for the upper. Mean relative error is 0.009 mm.</p><p><strong>Conclusion: </strong>Intraobserver reliability of a trained examiner is very high in the single measurement of the LCCD and validity is significant compared to more complex methods. The risk of bias is low since the mean of three LCCD measurements is calculated as opposed to recording only one single measurement.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333410/pdf/","citationCount":"0","resultStr":"{\"title\":\"Intraobserver reliability and validity of a single ultrasonic measurement of the lateral condyle-capsule distance in the temporomandibular joint.\",\"authors\":\"Raquel Delgado-Delgado, Orlando Conde-Vázquez, Fiona Mc Fall, Tomás Fernández-Rodríguez\",\"doi\":\"10.1007/s40477-023-00818-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of the study was to examine the reliability and validity of a single lateral condyle-capsule distance (LCCD) measurement while saving on economic costs and clinical resources.</p><p><strong>Methods: </strong>A longitudinal test-retest design was used to assess the reliability and validity of single-examiner measures over 72 TMJ sonographic analyses. Intraclass correlation coefficients (ICC) and a Bland-Altman plot were used to study reliability and validity, comparing the first measurement of the LCCD to the mean of 3 measurements taken one week later by the same examiner.</p><p><strong>Results: </strong>ICC show intraobserver reliability of 0.981, 95% confidence intervals (CI) of 0.969 to 0.988. The mean difference between the ultrasound measurements is 0.019 mm (95% CI 0.0005-0.0383) with a standard deviation of 0.080 mm, demonstrating robust validity. The 95% Limits of Agreement (LoA) are - 0.138 for the lower limit and 0.177 for the upper. Mean relative error is 0.009 mm.</p><p><strong>Conclusion: </strong>Intraobserver reliability of a trained examiner is very high in the single measurement of the LCCD and validity is significant compared to more complex methods. The risk of bias is low since the mean of three LCCD measurements is calculated as opposed to recording only one single measurement.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333410/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-023-00818-z\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-023-00818-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:该研究的目的是在节约经济成本和临床资源的同时,检验单一外侧髁-囊距离(LCCD)测量的可靠性和有效性:方法:采用纵向测试-重复测试设计,评估 72 次颞下颌关节声学分析中单一检查者测量的可靠性和有效性。使用类内相关系数(ICC)和Bland-Altman图研究可靠性和有效性,将LCCD的首次测量结果与同一检查者一周后进行的3次测量结果的平均值进行比较:ICC显示观察者内部可靠性为0.981,95%置信区间(CI)为0.969至0.988。超声测量结果之间的平均差为 0.019 毫米(95% CI 0.0005-0.0383),标准差为 0.080 毫米,显示出很强的有效性。95% 的一致性下限(LoA)为- 0.138,上限为 0.177。平均相对误差为 0.009 毫米:与更复杂的方法相比,训练有素的检查员对 LCCD 的单次测量具有很高的观察者内部可靠性和有效性。由于计算的是三次 LCCD 测量的平均值,而不是只记录一次测量结果,因此偏差风险较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intraobserver reliability and validity of a single ultrasonic measurement of the lateral condyle-capsule distance in the temporomandibular joint.

Purpose: The purpose of the study was to examine the reliability and validity of a single lateral condyle-capsule distance (LCCD) measurement while saving on economic costs and clinical resources.

Methods: A longitudinal test-retest design was used to assess the reliability and validity of single-examiner measures over 72 TMJ sonographic analyses. Intraclass correlation coefficients (ICC) and a Bland-Altman plot were used to study reliability and validity, comparing the first measurement of the LCCD to the mean of 3 measurements taken one week later by the same examiner.

Results: ICC show intraobserver reliability of 0.981, 95% confidence intervals (CI) of 0.969 to 0.988. The mean difference between the ultrasound measurements is 0.019 mm (95% CI 0.0005-0.0383) with a standard deviation of 0.080 mm, demonstrating robust validity. The 95% Limits of Agreement (LoA) are - 0.138 for the lower limit and 0.177 for the upper. Mean relative error is 0.009 mm.

Conclusion: Intraobserver reliability of a trained examiner is very high in the single measurement of the LCCD and validity is significant compared to more complex methods. The risk of bias is low since the mean of three LCCD measurements is calculated as opposed to recording only one single measurement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
期刊最新文献
Correction: Exploring the potential of contrast agents in breast cancer echography: current state and future directions. Effects of superficial tissue and intermuscular connections on rectus femoris muscle shear modulus heterogeneity. Evaluating acoustic and thermal properties of a plaque phantom. Role of acoustic radiation force impulse elastography of placenta in the diagnosis of pre-eclampsia. Intraobserver reliability and validity of a single ultrasonic measurement of the lateral condyle-capsule distance in the temporomandibular joint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1