自聚合丙烯酸树脂固化过程中单片与两片植入物的热变化。

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Oral & Maxillofacial Implants Pub Date : 2023-07-01 DOI:10.11607/jomi.10119
Gil Slutzkey, Roni Kolerman, Evgeny Weinberg, Liat Chaushu, Omer Cohen
{"title":"自聚合丙烯酸树脂固化过程中单片与两片植入物的热变化。","authors":"Gil Slutzkey,&nbsp;Roni Kolerman,&nbsp;Evgeny Weinberg,&nbsp;Liat Chaushu,&nbsp;Omer Cohen","doi":"10.11607/jomi.10119","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate differences in the temperature rise at the cervical area of one-piece vs two-piece implants during the setting of relined provisional crowns. <b>Materials and Methods:</b> A K-type thermocouple was fixed to the coronal thread of 15 one-piece implants and 15 two-piece implants that were mounted on a plexiglass apparatus. Baseline temperature (Bl Temp) was recorded before starting the curing process. The maximum temperature (Max Temp) reached during the process in both implant groups was also recorded. Total heat flux (THF) was calculated as well as the thermal amplitude (Temp-Amp) at the implant surface. Finally, the differences between the implant types were compared using unpaired <i>t</i> test. <b>Results:</b> The increase in temperature from baseline was statistically significantly greater in the one-piece implants than in the two-piece implants (<i>P</i> < .01). Similarly, the THF and Temp-Amp were significantly greater in the one-piece implants compared to two-piece implants (<i>P</i> < .01). <b>Conclusions:</b> The polymerization of PMMA-based resin temporary crowns produces a significant temperature rise in both one-piece and two-piece implants. It is advisable to use two-piece implants to restore immediately loaded implants to reduce the risk to implant surroundings that may occur due to the temperature rise at the implant neck.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal Changes of One-Piece Versus Two-Piece Implants During Setting of an Autopolymerized Acrylic Resin.\",\"authors\":\"Gil Slutzkey,&nbsp;Roni Kolerman,&nbsp;Evgeny Weinberg,&nbsp;Liat Chaushu,&nbsp;Omer Cohen\",\"doi\":\"10.11607/jomi.10119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose:</b> To evaluate differences in the temperature rise at the cervical area of one-piece vs two-piece implants during the setting of relined provisional crowns. <b>Materials and Methods:</b> A K-type thermocouple was fixed to the coronal thread of 15 one-piece implants and 15 two-piece implants that were mounted on a plexiglass apparatus. Baseline temperature (Bl Temp) was recorded before starting the curing process. The maximum temperature (Max Temp) reached during the process in both implant groups was also recorded. Total heat flux (THF) was calculated as well as the thermal amplitude (Temp-Amp) at the implant surface. Finally, the differences between the implant types were compared using unpaired <i>t</i> test. <b>Results:</b> The increase in temperature from baseline was statistically significantly greater in the one-piece implants than in the two-piece implants (<i>P</i> < .01). Similarly, the THF and Temp-Amp were significantly greater in the one-piece implants compared to two-piece implants (<i>P</i> < .01). <b>Conclusions:</b> The polymerization of PMMA-based resin temporary crowns produces a significant temperature rise in both one-piece and two-piece implants. It is advisable to use two-piece implants to restore immediately loaded implants to reduce the risk to implant surroundings that may occur due to the temperature rise at the implant neck.</p>\",\"PeriodicalId\":50298,\"journal\":{\"name\":\"International Journal of Oral & Maxillofacial Implants\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Oral & Maxillofacial Implants\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/jomi.10119\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10119","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估在换衬临时牙冠的设置过程中,一体式和两件式种植体的颈部温度升高的差异。材料和方法:将K型热电偶固定在安装在有机玻璃装置上的15个一体式植入物和15个两件式植入物的冠螺纹上。在开始固化过程之前记录基线温度(Bl-Temp)。还记录了两个植入物组在该过程中达到的最高温度(Max Temp)。计算总热通量(THF)以及植入物表面的热振幅(Temp-Amp)。最后,使用非配对t检验比较植入物类型之间的差异。结果:在统计学上,一体式植入物的温度自基线的升高显著大于两件式植入物(P<0.01),与两件式种植体相比,一体式种植体的THF和Temp-Amp显著更高(P<0.01)。结论:PMMA基树脂临时冠的聚合在一体式和两件式植入体中都会产生显著的温度升高。建议使用两件式植入物来恢复立即加载的植入物,以降低因植入物颈部温度升高而对植入物周围环境造成的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal Changes of One-Piece Versus Two-Piece Implants During Setting of an Autopolymerized Acrylic Resin.

Purpose: To evaluate differences in the temperature rise at the cervical area of one-piece vs two-piece implants during the setting of relined provisional crowns. Materials and Methods: A K-type thermocouple was fixed to the coronal thread of 15 one-piece implants and 15 two-piece implants that were mounted on a plexiglass apparatus. Baseline temperature (Bl Temp) was recorded before starting the curing process. The maximum temperature (Max Temp) reached during the process in both implant groups was also recorded. Total heat flux (THF) was calculated as well as the thermal amplitude (Temp-Amp) at the implant surface. Finally, the differences between the implant types were compared using unpaired t test. Results: The increase in temperature from baseline was statistically significantly greater in the one-piece implants than in the two-piece implants (P < .01). Similarly, the THF and Temp-Amp were significantly greater in the one-piece implants compared to two-piece implants (P < .01). Conclusions: The polymerization of PMMA-based resin temporary crowns produces a significant temperature rise in both one-piece and two-piece implants. It is advisable to use two-piece implants to restore immediately loaded implants to reduce the risk to implant surroundings that may occur due to the temperature rise at the implant neck.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
期刊最新文献
Peri-implant Parameters of Dental Implants Inserted in Prefabricated Microvascular Fibular Flaps: A Retrospective Study. Different Surgical Techniques in the All-on-4 Treatment Concept: Evaluation of the Stress Distribution Created in Implant and Peripheral Bone with Finite Element Analysis. Augmentation of Peri-implant Keratinized Mucosa Using a Combination of Free Gingival Graft Strip with Xenogeneic Collagen Matrix or Free Gingival Graft Alone: A Randomized Controlled Study. Efficacy of Labial Split-Thickness Eversion Periosteoplasty for Soft Tissue Management in Posterior Mandibular Horizontal Ridge Augmentation Procedures: A Prospective Clinical Study. Porcine Resorbable Collagen Matrix Shows Good Incorporation of Liquid Platelet-Rich Fibrin In Vitro.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1