佩戴Paragon CRT与欧几里德角膜塑形镜后治疗区相关因素的研究。

IF 2 4区 医学 Q2 OPHTHALMOLOGY Eye & Contact Lens-Science and Clinical Practice Pub Date : 2023-12-01 Epub Date: 2023-09-14 DOI:10.1097/ICL.0000000000001035
Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang
{"title":"佩戴Paragon CRT与欧几里德角膜塑形镜后治疗区相关因素的研究。","authors":"Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang","doi":"10.1097/ICL.0000000000001035","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.</p><p><strong>Methods: </strong>The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.</p><p><strong>Results: </strong>There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).</p><p><strong>Conclusion: </strong>For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":"521-527"},"PeriodicalIF":2.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659246/pdf/","citationCount":"0","resultStr":"{\"title\":\"Study on Related Factors of the Treatment Zone After Wearing Paragon CRT and Euclid Orthokeratology Lenses.\",\"authors\":\"Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang\",\"doi\":\"10.1097/ICL.0000000000001035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.</p><p><strong>Methods: </strong>The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.</p><p><strong>Results: </strong>There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).</p><p><strong>Conclusion: </strong>For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.</p>\",\"PeriodicalId\":50457,\"journal\":{\"name\":\"Eye & Contact Lens-Science and Clinical Practice\",\"volume\":\" \",\"pages\":\"521-527\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659246/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens-Science and Clinical Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000001035\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001035","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨Paragon CRT和Euclid角膜塑形镜配戴后治疗区直径(TZD)的影响因素及其与眼轴长生长(ALG)的关系。方法:回顾性分析2019年4月至2022年10月在苏州大学第一附属医院眼科配戴Paragon CRT和欧氏角膜塑形镜的近视患者的右眼资料。比较Paragon CRT组和Euclid组的TZD和ALG。分析两组患者配戴1个月后TZD的相关因素及重叠治疗区瞳面积比与配戴1年后ALG的关系。结果:Paragon CRT组160例(160眼),Euclid组155例(155眼)。佩带1个月后,Paragon CRT组的TZD(3.72±0.37 mm)大于Euclid组(3.26±0.37 mm) (p结论:无论是Paragon CRT还是Euclid角膜塑形术,角膜中央厚度越厚、Em越小的佩戴者TZD越小。在两组中,重叠治疗区面积与瞳孔面积之比与ALG相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on Related Factors of the Treatment Zone After Wearing Paragon CRT and Euclid Orthokeratology Lenses.

Objective: To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.

Methods: The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.

Results: There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).

Conclusion: For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
4.30%
发文量
150
审稿时长
6-12 weeks
期刊介绍: Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.
期刊最新文献
Contact Lens Regulation: Where Have We Been, Where are We Going? Corneal Refractive Surgery Considerations in Patients With History of Orthokeratology. Evaluation of Cyanoacrylate Tissue Adhesive Glue Application Outcomes in Corneal Thinning and Perforation. Spotlight on Amniotic Membrane Extract Eye Drops: A Review of the Literature. Corneal Clarity and Tomographic Patterns in Pseudoexfoliation Syndrome: A Severity-Based Investigation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1