角膜厚度测定法在规划白内障手术中的新作用,它能确定先前 LASIK 治疗导致的球面等值变化。

IF 1.8 4区 医学 Q3 OPHTHALMOLOGY Journal of Ophthalmology Pub Date : 2023-05-31 eCollection Date: 2023-01-01 DOI:10.1155/2023/2261831
Arthur Hammer, Tjebo F C Heeren, Romesh Angunawela, John Marshall, Kamran Saha
{"title":"角膜厚度测定法在规划白内障手术中的新作用,它能确定先前 LASIK 治疗导致的球面等值变化。","authors":"Arthur Hammer, Tjebo F C Heeren, Romesh Angunawela, John Marshall, Kamran Saha","doi":"10.1155/2023/2261831","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To provide a metric to differentiate between hyperopic and myopic ablation of a prior LASIK treatment based on the corneal pachymetry profile after laser vision correction (LVC).</p><p><strong>Methods: </strong>Pachymetry data were retrospectively recovered from patients who had previous LASIK for refractive purposes between 2019 and 2020. Patients with any corneal disorder were excluded. Ablation spherical equivalent was predicted from the central to semiperipheral corneal thickness (CPT) ratio, both values were provided by using the Pentacam user interface software (UI), and values were computed from extracted raw pachymetry data.</p><p><strong>Results: </strong>Data of 157 eyes of 81 patients were collected, of which data were analysed for 73 eyes of 73 patients to avoid concurrence of measurements in both eyes per subject (42% female; mean age 40.9; SD 12.8). The CPT ratio cutoff for distinction between myopic and hyperopic LASIK was 0.86 for Pentacam UI data. Sensitivity and specificity were 0.7 and 0.95, respectively. Accuracy increased with computation of the CPT ratio based on extracted raw data with sensitivity and specificity of 0.87 and 0.99, respectively. There was a marked linear correlation between the CPT ratio and the ablation spherical equivalent (<i>R</i><sup>2</sup> = 0.93).</p><p><strong>Conclusions: </strong>CPT ratio cutoffs can correctly classify if a cornea previously had a hyperopic versus myopic LASIK surgery and estimate the ablation spherical equivalent of such treatment. This could prove useful for increased accuracy of intraocular lens (IOL) calculations for patients with no historical data of their prior LVC surgery at the time of cataract surgery planning.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362985/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Novel Role for Corneal Pachymetry in Planning Cataract Surgery by Determining Changes in Spherical Equivalent Resulting from a Previous LASIK Treatment.\",\"authors\":\"Arthur Hammer, Tjebo F C Heeren, Romesh Angunawela, John Marshall, Kamran Saha\",\"doi\":\"10.1155/2023/2261831\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To provide a metric to differentiate between hyperopic and myopic ablation of a prior LASIK treatment based on the corneal pachymetry profile after laser vision correction (LVC).</p><p><strong>Methods: </strong>Pachymetry data were retrospectively recovered from patients who had previous LASIK for refractive purposes between 2019 and 2020. Patients with any corneal disorder were excluded. Ablation spherical equivalent was predicted from the central to semiperipheral corneal thickness (CPT) ratio, both values were provided by using the Pentacam user interface software (UI), and values were computed from extracted raw pachymetry data.</p><p><strong>Results: </strong>Data of 157 eyes of 81 patients were collected, of which data were analysed for 73 eyes of 73 patients to avoid concurrence of measurements in both eyes per subject (42% female; mean age 40.9; SD 12.8). The CPT ratio cutoff for distinction between myopic and hyperopic LASIK was 0.86 for Pentacam UI data. Sensitivity and specificity were 0.7 and 0.95, respectively. Accuracy increased with computation of the CPT ratio based on extracted raw data with sensitivity and specificity of 0.87 and 0.99, respectively. There was a marked linear correlation between the CPT ratio and the ablation spherical equivalent (<i>R</i><sup>2</sup> = 0.93).</p><p><strong>Conclusions: </strong>CPT ratio cutoffs can correctly classify if a cornea previously had a hyperopic versus myopic LASIK surgery and estimate the ablation spherical equivalent of such treatment. This could prove useful for increased accuracy of intraocular lens (IOL) calculations for patients with no historical data of their prior LVC surgery at the time of cataract surgery planning.</p>\",\"PeriodicalId\":16674,\"journal\":{\"name\":\"Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362985/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/2261831\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/2261831","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的根据激光视力矫正(LVC)后的角膜厚度曲线,提供一种区分先前 LASIK 治疗的远视和近视消融的指标:方法:从2019年至2020年期间曾因屈光目的接受过LASIK治疗的患者中回顾性地恢复了角膜厚度数据。排除了患有任何角膜疾病的患者。根据中央与半周角膜厚度(CPT)比值预测消融球面等值,这两个值均由 Pentacam 用户界面软件(UI)提供,并根据提取的原始测径数据计算值:收集了 81 名患者 157 只眼睛的数据,其中 73 名患者的 73 只眼睛的数据进行了分析,以避免每名受试者(42% 为女性;平均年龄 40.9 岁;标准差 12.8)的双眼测量数据相同。对于 Pentacam UI 数据,区分近视和远视 LASIK 的 CPT 比值临界值为 0.86。灵敏度和特异度分别为 0.7 和 0.95。根据提取的原始数据计算 CPT 比值后,准确度有所提高,灵敏度和特异度分别为 0.87 和 0.99。CPT 比值与消融球面等值之间存在明显的线性相关(R2 = 0.93):结论:CPT 比值临界值能正确区分角膜是否曾接受过远视或近视 LASIK 手术,并估算出此类治疗的消融球面等值。结论:CPT 比值临界值能正确区分角膜是否曾接受过远视或近视 LASIK 手术,并估算出此类治疗的消融球面等值,这对于在白内障手术规划时没有 LVC 手术历史数据的患者来说,有助于提高眼内晶状体(IOL)计算的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel Role for Corneal Pachymetry in Planning Cataract Surgery by Determining Changes in Spherical Equivalent Resulting from a Previous LASIK Treatment.

Objectives: To provide a metric to differentiate between hyperopic and myopic ablation of a prior LASIK treatment based on the corneal pachymetry profile after laser vision correction (LVC).

Methods: Pachymetry data were retrospectively recovered from patients who had previous LASIK for refractive purposes between 2019 and 2020. Patients with any corneal disorder were excluded. Ablation spherical equivalent was predicted from the central to semiperipheral corneal thickness (CPT) ratio, both values were provided by using the Pentacam user interface software (UI), and values were computed from extracted raw pachymetry data.

Results: Data of 157 eyes of 81 patients were collected, of which data were analysed for 73 eyes of 73 patients to avoid concurrence of measurements in both eyes per subject (42% female; mean age 40.9; SD 12.8). The CPT ratio cutoff for distinction between myopic and hyperopic LASIK was 0.86 for Pentacam UI data. Sensitivity and specificity were 0.7 and 0.95, respectively. Accuracy increased with computation of the CPT ratio based on extracted raw data with sensitivity and specificity of 0.87 and 0.99, respectively. There was a marked linear correlation between the CPT ratio and the ablation spherical equivalent (R2 = 0.93).

Conclusions: CPT ratio cutoffs can correctly classify if a cornea previously had a hyperopic versus myopic LASIK surgery and estimate the ablation spherical equivalent of such treatment. This could prove useful for increased accuracy of intraocular lens (IOL) calculations for patients with no historical data of their prior LVC surgery at the time of cataract surgery planning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
期刊最新文献
Optical Coherence Tomography Angiography: Investigating Vessel Density Changes Induced by Caffeine in Healthy Subjects. Pathological Mechanism and Clinical Therapy Progress of Schlemm's Canal. Results of XEN45 Gel Stent Implantation in the Treatment of Primary Open-Angle Glaucoma Using 5, 10 or 20 μg Mitomycin C: A Pilot Study. Lens Displacement and Retinal Injury in Blunt Eye Trauma. CHA2DS2-VASc Score in Predicting Visual Acuity Outcomes Following Retinal Vein Occlusion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1