三维T1-Turbo自旋回波成像对颅内支架置入术评价的价值。

Hiroyuki Mizuno, Masanori Aihara, Koji Sato, Chikashi Negishi, Nobuo Sasaguchi, Hideyuki Kurihara, Yuhei Yoshimoto
{"title":"三维T1-Turbo自旋回波成像对颅内支架置入术评价的价值。","authors":"Hiroyuki Mizuno,&nbsp;Masanori Aihara,&nbsp;Koji Sato,&nbsp;Chikashi Negishi,&nbsp;Nobuo Sasaguchi,&nbsp;Hideyuki Kurihara,&nbsp;Yuhei Yoshimoto","doi":"10.5797/jnet.oa.2022-0039","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement.</p><p><strong>Methods: </strong>The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site.</p><p><strong>Results: </strong>The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site.</p><p><strong>Conclusion: </strong>3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion.</p>","PeriodicalId":73856,"journal":{"name":"Journal of neuroendovascular therapy","volume":"17 1","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/28/jnet-17-01.PMC10370516.pdf","citationCount":"0","resultStr":"{\"title\":\"Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement.\",\"authors\":\"Hiroyuki Mizuno,&nbsp;Masanori Aihara,&nbsp;Koji Sato,&nbsp;Chikashi Negishi,&nbsp;Nobuo Sasaguchi,&nbsp;Hideyuki Kurihara,&nbsp;Yuhei Yoshimoto\",\"doi\":\"10.5797/jnet.oa.2022-0039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement.</p><p><strong>Methods: </strong>The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site.</p><p><strong>Results: </strong>The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site.</p><p><strong>Conclusion: </strong>3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion.</p>\",\"PeriodicalId\":73856,\"journal\":{\"name\":\"Journal of neuroendovascular therapy\",\"volume\":\"17 1\",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/28/jnet-17-01.PMC10370516.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neuroendovascular therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5797/jnet.oa.2022-0039\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neuroendovascular therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5797/jnet.oa.2022-0039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:MRI评估颅内支架置入存在飞行时间MRA (TOF-MRA)信号伪影问题。因此,需要血管造影检查对支架放置部位进行详细的血管内评估。最近,3D T1-turbo自旋回波(3D- tse)被开发用于评估颈动脉支架置入。我们研究了使用3D-TSE成像方法评估颅内血管支架置入。方法:研究对象为2015年4月至2019年12月接受颅内血管支架置入术的9例患者。术后通过TOF-MRA、DSA和3D-TSE成像测量置入支架的管腔。根据支架类型和放置位置进行分析。结果:使用的支架分别为Neuroform Atlas(3例)、LVIS(3例)、LVIS Jr(2例)、Integrity(1例)。9例患者支架置入部位的TOF-MRA图像均显示有缺陷或显示不佳,而3D-TSE成像均显示支架置入部位的管腔。无论支架类型和放置位置如何,DSA测量的血管直径与3D-TSE成像呈正相关。结论:3D-TSE成像可以显示颅内血管支架部位的管腔,无论支架或血管的类型如何。因此,该方法可用于评估病变的血管腔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement.

Objective: Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement.

Methods: The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site.

Results: The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site.

Conclusion: 3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Case of Acute Ischemic Stroke due to Tandem Lesion Treated with Endovascular Thrombectomy by Internal Carotid Artery Direct Puncture. A Case of Cavernous Sinus Dural Arteriovenous Fistula with Persistent Left Superior Vena Cava. A Case of Flow Diverter Placement for a Recurrent Large Thrombosed Middle Cerebral Artery Aneurysm. An Updated Review on the Pathogenesis of Brain Arteriovenous Malformations and Its Therapeutic Targets. Early Antithrombotic Therapy in Acute Ischemic Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1