Stephen K McHale, Sarah L Whitehouse, Jonathan R Howell, Matthew Jw Hubble, A John Timperley, Matthew J Wilson
{"title":"采用陶瓷基底的 Exeter-Trident THA:275 例全髋关节置换术的 10 年疗效。","authors":"Stephen K McHale, Sarah L Whitehouse, Jonathan R Howell, Matthew Jw Hubble, A John Timperley, Matthew J Wilson","doi":"10.1177/11207000231198220","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>This study reports on the Exeter-Trident total hip arthroplasty (THA) using an alumina ceramic-on-ceramic bearing with 10-year clinical and radiographic follow-up.</p><p><strong>Patients and methods: </strong>Between January 2001 and January 2006, 275 THAs were performed. Mean age at surgery was 52.7 (17-86) years, with 84 patients (33.6%) aged <50 years. The primary outcome was all-cause construct survival at minimum 10 years. Secondary outcomes included functional and noise scores. Radiographs were compared between baseline and latest follow-up and assessed for component loosening, migration and lysis.</p><p><strong>Results: </strong>No patient was lost to follow-up. Mean follow-up for surviving patients was 12.5 (9.5-15.6) years. Kaplan-Meier survival for all-cause revision was 94.0% (95% CI, 90.5-97.5) at 14.3 years. 2 patients had a femoral component fracture. All scores improved significantly at latest follow-up. HSS-NQ for 247 hips (90.2%) at mean 9.1 (7.0-14.4) years post implantation showed most hips (93.1%) reported no more than occasional noise. At minimum 5 years, radiolucency around the acetabular component was observed in 2 hips (0.8%), and lysis at the interface in 1 hip (0.4%). On the femoral side, endosteal lysis was observed in 7 hips.</p><p><strong>Conclusions: </strong>The Exeter-Trident THA with alumina ceramic-on-ceramic bearings performed well in this population. Patients are at low risk of revision in the first decade. However, there is a small risk of stem fracture as a late complication and some patients experience significant noise.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":" ","pages":"187-193"},"PeriodicalIF":1.3000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Exeter-Trident THA with ceramic-on-ceramic-bearings: 10-year outcomes in 275 total hip arthroplasties.\",\"authors\":\"Stephen K McHale, Sarah L Whitehouse, Jonathan R Howell, Matthew Jw Hubble, A John Timperley, Matthew J Wilson\",\"doi\":\"10.1177/11207000231198220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>This study reports on the Exeter-Trident total hip arthroplasty (THA) using an alumina ceramic-on-ceramic bearing with 10-year clinical and radiographic follow-up.</p><p><strong>Patients and methods: </strong>Between January 2001 and January 2006, 275 THAs were performed. Mean age at surgery was 52.7 (17-86) years, with 84 patients (33.6%) aged <50 years. The primary outcome was all-cause construct survival at minimum 10 years. Secondary outcomes included functional and noise scores. Radiographs were compared between baseline and latest follow-up and assessed for component loosening, migration and lysis.</p><p><strong>Results: </strong>No patient was lost to follow-up. Mean follow-up for surviving patients was 12.5 (9.5-15.6) years. Kaplan-Meier survival for all-cause revision was 94.0% (95% CI, 90.5-97.5) at 14.3 years. 2 patients had a femoral component fracture. All scores improved significantly at latest follow-up. HSS-NQ for 247 hips (90.2%) at mean 9.1 (7.0-14.4) years post implantation showed most hips (93.1%) reported no more than occasional noise. At minimum 5 years, radiolucency around the acetabular component was observed in 2 hips (0.8%), and lysis at the interface in 1 hip (0.4%). On the femoral side, endosteal lysis was observed in 7 hips.</p><p><strong>Conclusions: </strong>The Exeter-Trident THA with alumina ceramic-on-ceramic bearings performed well in this population. Patients are at low risk of revision in the first decade. However, there is a small risk of stem fracture as a late complication and some patients experience significant noise.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":\" \",\"pages\":\"187-193\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000231198220\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231198220","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
The Exeter-Trident THA with ceramic-on-ceramic-bearings: 10-year outcomes in 275 total hip arthroplasties.
Aims: This study reports on the Exeter-Trident total hip arthroplasty (THA) using an alumina ceramic-on-ceramic bearing with 10-year clinical and radiographic follow-up.
Patients and methods: Between January 2001 and January 2006, 275 THAs were performed. Mean age at surgery was 52.7 (17-86) years, with 84 patients (33.6%) aged <50 years. The primary outcome was all-cause construct survival at minimum 10 years. Secondary outcomes included functional and noise scores. Radiographs were compared between baseline and latest follow-up and assessed for component loosening, migration and lysis.
Results: No patient was lost to follow-up. Mean follow-up for surviving patients was 12.5 (9.5-15.6) years. Kaplan-Meier survival for all-cause revision was 94.0% (95% CI, 90.5-97.5) at 14.3 years. 2 patients had a femoral component fracture. All scores improved significantly at latest follow-up. HSS-NQ for 247 hips (90.2%) at mean 9.1 (7.0-14.4) years post implantation showed most hips (93.1%) reported no more than occasional noise. At minimum 5 years, radiolucency around the acetabular component was observed in 2 hips (0.8%), and lysis at the interface in 1 hip (0.4%). On the femoral side, endosteal lysis was observed in 7 hips.
Conclusions: The Exeter-Trident THA with alumina ceramic-on-ceramic bearings performed well in this population. Patients are at low risk of revision in the first decade. However, there is a small risk of stem fracture as a late complication and some patients experience significant noise.
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology