超声进入腔制备对牙本质内壁的影响:对尸体样本的显微CT研究。

IF 1.6 3区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Oral Radiology Pub Date : 2023-10-01 Epub Date: 2023-03-31 DOI:10.1007/s11282-023-00680-z
C Zogheib, R Roumi, A Baldi, P Palopoli, D Pasqualini, E Berutti, M Alovisi
{"title":"超声进入腔制备对牙本质内壁的影响:对尸体样本的显微CT研究。","authors":"C Zogheib,&nbsp;R Roumi,&nbsp;A Baldi,&nbsp;P Palopoli,&nbsp;D Pasqualini,&nbsp;E Berutti,&nbsp;M Alovisi","doi":"10.1007/s11282-023-00680-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study is to evaluate the occurrence of coronal dentinal micro-cracks after access cavity refinement using high-speed burs and ultrasonic tips by means of micro-computed tomography (micro-CT) analysis.</p><p><strong>Methods: </strong>In this study, 18 mandibular cadaveric incisors were divided into two groups according to the protocol of the preparation of the conventional access cavity. The diamond bur 802 # 12 was used until the perforation of the pulp roof. Then, the Endo-Z bur was used for the group #1 and the ultrasonic tip Start-X # 1 for the group #2 to finish and refine the access cavity. The preparation time of each access cavity has been recorded. The teeth underwent a micro-CT scan before and after the preparation of the access cavity. Fisher's exact test, the Chi-square test, the Kolmogorov-Smirnov test, the Mann-Whitney test, and the Student's test were used for statistical evaluation.</p><p><strong>Results: </strong>The percentage of teeth with new micro-cracks is not significantly different between the two groups (-p-value < 0.5). The number of newly formed micro-cracks and extension size were not significantly different between the two groups. The direction of extension of the micro- cracks was occluso-apical. The average duration of the access cavity is significantly smaller with the Endo-Z system (-p- value < 0.001). The roughness of walls surfaces has no statistically difference between the two groups.</p><p><strong>Conclusion: </strong>The use of ultrasound, although slower, is considered safe in the creation of dentinal micro-cracks, in the preparation of the access cavity.</p>","PeriodicalId":56103,"journal":{"name":"Oral Radiology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of ultrasonic access cavity preparation on dentinal inner walls: a micro-CT study on cadaveric samples.\",\"authors\":\"C Zogheib,&nbsp;R Roumi,&nbsp;A Baldi,&nbsp;P Palopoli,&nbsp;D Pasqualini,&nbsp;E Berutti,&nbsp;M Alovisi\",\"doi\":\"10.1007/s11282-023-00680-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The objective of this study is to evaluate the occurrence of coronal dentinal micro-cracks after access cavity refinement using high-speed burs and ultrasonic tips by means of micro-computed tomography (micro-CT) analysis.</p><p><strong>Methods: </strong>In this study, 18 mandibular cadaveric incisors were divided into two groups according to the protocol of the preparation of the conventional access cavity. The diamond bur 802 # 12 was used until the perforation of the pulp roof. Then, the Endo-Z bur was used for the group #1 and the ultrasonic tip Start-X # 1 for the group #2 to finish and refine the access cavity. The preparation time of each access cavity has been recorded. The teeth underwent a micro-CT scan before and after the preparation of the access cavity. Fisher's exact test, the Chi-square test, the Kolmogorov-Smirnov test, the Mann-Whitney test, and the Student's test were used for statistical evaluation.</p><p><strong>Results: </strong>The percentage of teeth with new micro-cracks is not significantly different between the two groups (-p-value < 0.5). The number of newly formed micro-cracks and extension size were not significantly different between the two groups. The direction of extension of the micro- cracks was occluso-apical. The average duration of the access cavity is significantly smaller with the Endo-Z system (-p- value < 0.001). The roughness of walls surfaces has no statistically difference between the two groups.</p><p><strong>Conclusion: </strong>The use of ultrasound, although slower, is considered safe in the creation of dentinal micro-cracks, in the preparation of the access cavity.</p>\",\"PeriodicalId\":56103,\"journal\":{\"name\":\"Oral Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11282-023-00680-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11282-023-00680-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是通过微型计算机断层扫描(micro-CT)分析,评估使用高速囊和超声尖端进行口腔细化后冠状牙本质微裂纹的发生情况。方法:本研究将18具下颌尸体切牙按常规入口腔预备方案分为两组。金刚石钻头802#12一直使用到髓顶穿孔为止。然后,Endo-Z钻用于组#1,超声尖端Start-X#1用于组#2,以完成和细化进入腔。记录了每个进入腔的准备时间。在准备进入腔之前和之后,对牙齿进行了显微CT扫描。Fisher精确检验、卡方检验、Kolmogorov-Smirnov检验、Mann-Whitney检验和Student检验用于统计评估。结果:两组牙齿出现新微裂纹的百分比没有显著差异(-p值 结论:超声的使用虽然较慢,但在牙本质微裂纹的形成和进入腔的制备中被认为是安全的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of ultrasonic access cavity preparation on dentinal inner walls: a micro-CT study on cadaveric samples.

Objective: The objective of this study is to evaluate the occurrence of coronal dentinal micro-cracks after access cavity refinement using high-speed burs and ultrasonic tips by means of micro-computed tomography (micro-CT) analysis.

Methods: In this study, 18 mandibular cadaveric incisors were divided into two groups according to the protocol of the preparation of the conventional access cavity. The diamond bur 802 # 12 was used until the perforation of the pulp roof. Then, the Endo-Z bur was used for the group #1 and the ultrasonic tip Start-X # 1 for the group #2 to finish and refine the access cavity. The preparation time of each access cavity has been recorded. The teeth underwent a micro-CT scan before and after the preparation of the access cavity. Fisher's exact test, the Chi-square test, the Kolmogorov-Smirnov test, the Mann-Whitney test, and the Student's test were used for statistical evaluation.

Results: The percentage of teeth with new micro-cracks is not significantly different between the two groups (-p-value < 0.5). The number of newly formed micro-cracks and extension size were not significantly different between the two groups. The direction of extension of the micro- cracks was occluso-apical. The average duration of the access cavity is significantly smaller with the Endo-Z system (-p- value < 0.001). The roughness of walls surfaces has no statistically difference between the two groups.

Conclusion: The use of ultrasound, although slower, is considered safe in the creation of dentinal micro-cracks, in the preparation of the access cavity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Oral Radiology
Oral Radiology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.20
自引率
13.60%
发文量
87
审稿时长
>12 weeks
期刊介绍: As the official English-language journal of the Japanese Society for Oral and Maxillofacial Radiology and the Asian Academy of Oral and Maxillofacial Radiology, Oral Radiology is intended to be a forum for international collaboration in head and neck diagnostic imaging and all related fields. Oral Radiology features cutting-edge research papers, review articles, case reports, and technical notes from both the clinical and experimental fields. As membership in the Society is not a prerequisite, contributions are welcome from researchers and clinicians worldwide.
期刊最新文献
Style harmonization of panoramic radiography using deep learning. Evaluation of root canal filling length on periapical radiograph using artificial intelligence. Combined external radiotherapy and single-fraction palliative high-dose-rate interstitial brachytherapy for a patient with a base of tongue cancer who had a previous radiation history. Effect of metallic materials on magnetic resonance image uniformity: a quantitative experimental study. Acceptability of artificial intelligence in dental radiology among patients in India: are we ready for this revolution?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1