健康受试者和不同程度功能性三尖瓣反流患者三尖瓣环几何形状的三维分析。

IF 1.9 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiovascular Ultrasound Pub Date : 2023-09-15 DOI:10.1186/s12947-023-00315-7
Gintarė Bieliauskienė, Ieva Kažukauskienė, Rita Kramena, Aleksejus Zorinas, Antanas Mainelis, Diana Zakarkaitė
{"title":"健康受试者和不同程度功能性三尖瓣反流患者三尖瓣环几何形状的三维分析。","authors":"Gintarė Bieliauskienė, Ieva Kažukauskienė, Rita Kramena, Aleksejus Zorinas, Antanas Mainelis, Diana Zakarkaitė","doi":"10.1186/s12947-023-00315-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understanding of its spatial anatomy and enables more accurate measurements of TV structures.</p><p><strong>Objectives: </strong>The study aimed to analyze tricuspid annulus (TA) parameters in normal heart and in different grades of functional tricuspid regurgitation (TR); to compare TA measurements obtained by 2D and 3D echocardiography.</p><p><strong>Methods: </strong>One hundred fifty-five patients (median age 65 years, 57% women) with normal TV and different functional TR grades underwent 2D and 3D transthoracic echocardiography. The severity of TR was estimated using multiparametric assessment according to the guidelines. Mid-systolic 3D TA parameters were calculated using TV dedicated software. The conventional 2D systolic TA measurements in a standard four-chamber view were performed.</p><p><strong>Results: </strong>In mid-systole, the normal TA area was 9.2 ± 2.0 cm<sup>2</sup> for men and 7.4 ± 1.6 cm<sup>2</sup> for women. When indexed to body surface area (BSA), there were no significant differences in the 3D parameters between genders. The 2D TA diameters were smaller than those measured in 3D. The ROC curve analysis identified that all 3D TA parameters can accurately differentiate between different functional TR grades. Additionally, the optimal cut-off values were identified for each TA parameter.</p><p><strong>Conclusions: </strong>Gender, body size, and age have an impact on the TA parameters in healthy subjects. 2D measurements are smaller than 3D parameters. The reference values for 3D metrics according to TR severity can help in identifying TA dilation and distinguishing between different functional TR grades.</p>","PeriodicalId":9613,"journal":{"name":"Cardiovascular Ultrasound","volume":"21 1","pages":"17"},"PeriodicalIF":1.9000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503068/pdf/","citationCount":"1","resultStr":"{\"title\":\"Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation.\",\"authors\":\"Gintarė Bieliauskienė, Ieva Kažukauskienė, Rita Kramena, Aleksejus Zorinas, Antanas Mainelis, Diana Zakarkaitė\",\"doi\":\"10.1186/s12947-023-00315-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understanding of its spatial anatomy and enables more accurate measurements of TV structures.</p><p><strong>Objectives: </strong>The study aimed to analyze tricuspid annulus (TA) parameters in normal heart and in different grades of functional tricuspid regurgitation (TR); to compare TA measurements obtained by 2D and 3D echocardiography.</p><p><strong>Methods: </strong>One hundred fifty-five patients (median age 65 years, 57% women) with normal TV and different functional TR grades underwent 2D and 3D transthoracic echocardiography. The severity of TR was estimated using multiparametric assessment according to the guidelines. Mid-systolic 3D TA parameters were calculated using TV dedicated software. The conventional 2D systolic TA measurements in a standard four-chamber view were performed.</p><p><strong>Results: </strong>In mid-systole, the normal TA area was 9.2 ± 2.0 cm<sup>2</sup> for men and 7.4 ± 1.6 cm<sup>2</sup> for women. When indexed to body surface area (BSA), there were no significant differences in the 3D parameters between genders. The 2D TA diameters were smaller than those measured in 3D. The ROC curve analysis identified that all 3D TA parameters can accurately differentiate between different functional TR grades. Additionally, the optimal cut-off values were identified for each TA parameter.</p><p><strong>Conclusions: </strong>Gender, body size, and age have an impact on the TA parameters in healthy subjects. 2D measurements are smaller than 3D parameters. The reference values for 3D metrics according to TR severity can help in identifying TA dilation and distinguishing between different functional TR grades.</p>\",\"PeriodicalId\":9613,\"journal\":{\"name\":\"Cardiovascular Ultrasound\",\"volume\":\"21 1\",\"pages\":\"17\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10503068/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12947-023-00315-7\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12947-023-00315-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

摘要

背景:三尖瓣瓣环的精确尺寸对于确定三尖瓣瓣(TV)干预的最佳时机至关重要。二维超声心动图对综合电视分析有局限性。瓣膜的三维(3D)成像可以更好地了解其空间解剖结构,并能够更准确地测量电视结构。目的:分析正常心脏和不同程度功能性三尖瓣反流(TR)的三尖瓣环(TA)参数;比较二维和三维超声心动图的TA测量结果。方法:155例TV正常、TR功能分级不同的患者(中位年龄65岁,57%为女性)行二维和三维经胸超声心动图检查。根据指南采用多参数评估方法估计TR的严重程度。采用电视专用软件计算收缩期三维TA参数。在标准四室视图下进行常规二维收缩期TA测量。结果:收缩期中期,男性TA正常面积为9.2±2.0 cm2,女性为7.4±1.6 cm2。当以体表面积(BSA)为指标时,性别之间的3D参数无显著差异。二维TA直径小于三维TA直径。ROC曲线分析发现,所有3D TA参数均能准确区分不同功能TR等级。此外,还确定了每个TA参数的最佳截止值。结论:性别、体型和年龄对健康受试者的TA参数有影响。2D测量值小于3D参数。根据TR严重程度的三维指标参考值有助于识别TA扩张和区分不同的功能TR等级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Three-dimensional analysis of the tricuspid annular geometry in healthy subjects and in patients with different grades of functional tricuspid regurgitation.

Background: Accurate sizing of the tricuspid valve annulus is essential for determining the optimal timing of tricuspid valve (TV) intervention. Two-dimensional (2D) echocardiography has limitations for comprehensive TV analysis. Three-dimensional (3D) imaging of the valve provides a better understanding of its spatial anatomy and enables more accurate measurements of TV structures.

Objectives: The study aimed to analyze tricuspid annulus (TA) parameters in normal heart and in different grades of functional tricuspid regurgitation (TR); to compare TA measurements obtained by 2D and 3D echocardiography.

Methods: One hundred fifty-five patients (median age 65 years, 57% women) with normal TV and different functional TR grades underwent 2D and 3D transthoracic echocardiography. The severity of TR was estimated using multiparametric assessment according to the guidelines. Mid-systolic 3D TA parameters were calculated using TV dedicated software. The conventional 2D systolic TA measurements in a standard four-chamber view were performed.

Results: In mid-systole, the normal TA area was 9.2 ± 2.0 cm2 for men and 7.4 ± 1.6 cm2 for women. When indexed to body surface area (BSA), there were no significant differences in the 3D parameters between genders. The 2D TA diameters were smaller than those measured in 3D. The ROC curve analysis identified that all 3D TA parameters can accurately differentiate between different functional TR grades. Additionally, the optimal cut-off values were identified for each TA parameter.

Conclusions: Gender, body size, and age have an impact on the TA parameters in healthy subjects. 2D measurements are smaller than 3D parameters. The reference values for 3D metrics according to TR severity can help in identifying TA dilation and distinguishing between different functional TR grades.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Ultrasound
Cardiovascular Ultrasound CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.10
自引率
0.00%
发文量
28
审稿时长
>12 weeks
期刊介绍: Cardiovascular Ultrasound is an online journal, publishing peer-reviewed: original research; authoritative reviews; case reports on challenging and/or unusual diagnostic aspects; and expert opinions on new techniques and technologies. We are particularly interested in articles that include relevant images or video files, which provide an additional dimension to published articles and enhance understanding. As an open access journal, Cardiovascular Ultrasound ensures high visibility for authors in addition to providing an up-to-date and freely available resource for the community. The journal welcomes discussion, and provides a forum for publishing opinion and debate ranging from biology to engineering to clinical echocardiography, with both speed and versatility.
期刊最新文献
Left atrial strain in patients without cardiovascular disease: uncovering influencing and related factors. Left atrial function during exercise stress echocardiography as a sign of paroxysmal/persistent atrial fibrillation. 'Color Doppler stripes' make it difficult to diagnose the severity of valvular heart diseases: a report of two cases. Effects of smoking cessation on endothelial function as assessed by flow-mediated total dilation. Ultrasound enhancing agents in cardiovascular imaging: expanding horizons beyond coronary arteries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1