Karl H Pang, Nim Christopher, David J Ralph, Wai Gin Lee
{"title":"将可充气阴茎假体插入指定女性出生个体的新阴茎:手术技术、并发症和结果的系统综述。","authors":"Karl H Pang, Nim Christopher, David J Ralph, Wai Gin Lee","doi":"10.1177/17562872231199584","DOIUrl":null,"url":null,"abstract":"<p><p>Devices such as inflatable penile prostheses (IPP) can be used to achieve erectile rigidity after phalloplasty in assigned female at birth (AFAB) individuals. The approach to inserting an IPP in a neophallus is different and more challenging compared to that of an anatomical penis due to the absence of anatomical structures such as the corpora cavernosa, and the more tenuous blood supply of the neophallus and reconstructed urethra. In addition, the ideal surgical techniques and devices for use in the neophallus have not been defined. This review systematically summarises the literature on the insertion of IPP in the neophallus of individuals AFAB. In particular, the described techniques, types of devices used and peri-operative and patient-reported outcomes are emphasised. An initial search of the PubMed database was performed on 16 September 2022 and an updated search was performed on 26 May 2023. Overall, 185 articles were screened for eligibility and 15 studies fulfilled the inclusion criteria and were included in the analysis. Two studies reported outcomes on the zephyr surgical implant 475 FTM device and the others reported outcomes on the Boston Scientific AMS 600/700<sup>TM</sup> CX 3-piece inflatable, AMS Ambicor<sup>TM</sup> 2-piece inflatable, Coloplast Titan<sup>®</sup> or Dynaflex devices. Overall, 1106 IPPs were analysed. The infection rate was 4.2%-50%, with most studies reporting an infection rate of <30%. Mechanical failure or dysfunction occurred in 1.4%-36.4%, explantation was required in 3.3%-41.6%, and implant revision or replacement was performed in 6%-70%. Overall, 51.4%-90.6% of patients were satisfied and 77%-100% were engaging in sexual intercourse. An IPP in a neophallus is an acceptable option to achieve rigidity for sexual intercourse. However, this challenging procedure has good reports of patient and partner satisfaction despite significant risks of complications.</p>","PeriodicalId":23010,"journal":{"name":"Therapeutic Advances in Urology","volume":"15 ","pages":"17562872231199584"},"PeriodicalIF":2.6000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/14/c3/10.1177_17562872231199584.PMC10503286.pdf","citationCount":"1","resultStr":"{\"title\":\"Insertion of inflatable penile prosthesis in the neophallus of assigned female at birth individuals: a systematic review of surgical techniques, complications and outcomes.\",\"authors\":\"Karl H Pang, Nim Christopher, David J Ralph, Wai Gin Lee\",\"doi\":\"10.1177/17562872231199584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Devices such as inflatable penile prostheses (IPP) can be used to achieve erectile rigidity after phalloplasty in assigned female at birth (AFAB) individuals. The approach to inserting an IPP in a neophallus is different and more challenging compared to that of an anatomical penis due to the absence of anatomical structures such as the corpora cavernosa, and the more tenuous blood supply of the neophallus and reconstructed urethra. In addition, the ideal surgical techniques and devices for use in the neophallus have not been defined. This review systematically summarises the literature on the insertion of IPP in the neophallus of individuals AFAB. In particular, the described techniques, types of devices used and peri-operative and patient-reported outcomes are emphasised. An initial search of the PubMed database was performed on 16 September 2022 and an updated search was performed on 26 May 2023. Overall, 185 articles were screened for eligibility and 15 studies fulfilled the inclusion criteria and were included in the analysis. Two studies reported outcomes on the zephyr surgical implant 475 FTM device and the others reported outcomes on the Boston Scientific AMS 600/700<sup>TM</sup> CX 3-piece inflatable, AMS Ambicor<sup>TM</sup> 2-piece inflatable, Coloplast Titan<sup>®</sup> or Dynaflex devices. Overall, 1106 IPPs were analysed. The infection rate was 4.2%-50%, with most studies reporting an infection rate of <30%. Mechanical failure or dysfunction occurred in 1.4%-36.4%, explantation was required in 3.3%-41.6%, and implant revision or replacement was performed in 6%-70%. Overall, 51.4%-90.6% of patients were satisfied and 77%-100% were engaging in sexual intercourse. An IPP in a neophallus is an acceptable option to achieve rigidity for sexual intercourse. However, this challenging procedure has good reports of patient and partner satisfaction despite significant risks of complications.</p>\",\"PeriodicalId\":23010,\"journal\":{\"name\":\"Therapeutic Advances in Urology\",\"volume\":\"15 \",\"pages\":\"17562872231199584\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/14/c3/10.1177_17562872231199584.PMC10503286.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Urology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17562872231199584\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17562872231199584","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Insertion of inflatable penile prosthesis in the neophallus of assigned female at birth individuals: a systematic review of surgical techniques, complications and outcomes.
Devices such as inflatable penile prostheses (IPP) can be used to achieve erectile rigidity after phalloplasty in assigned female at birth (AFAB) individuals. The approach to inserting an IPP in a neophallus is different and more challenging compared to that of an anatomical penis due to the absence of anatomical structures such as the corpora cavernosa, and the more tenuous blood supply of the neophallus and reconstructed urethra. In addition, the ideal surgical techniques and devices for use in the neophallus have not been defined. This review systematically summarises the literature on the insertion of IPP in the neophallus of individuals AFAB. In particular, the described techniques, types of devices used and peri-operative and patient-reported outcomes are emphasised. An initial search of the PubMed database was performed on 16 September 2022 and an updated search was performed on 26 May 2023. Overall, 185 articles were screened for eligibility and 15 studies fulfilled the inclusion criteria and were included in the analysis. Two studies reported outcomes on the zephyr surgical implant 475 FTM device and the others reported outcomes on the Boston Scientific AMS 600/700TM CX 3-piece inflatable, AMS AmbicorTM 2-piece inflatable, Coloplast Titan® or Dynaflex devices. Overall, 1106 IPPs were analysed. The infection rate was 4.2%-50%, with most studies reporting an infection rate of <30%. Mechanical failure or dysfunction occurred in 1.4%-36.4%, explantation was required in 3.3%-41.6%, and implant revision or replacement was performed in 6%-70%. Overall, 51.4%-90.6% of patients were satisfied and 77%-100% were engaging in sexual intercourse. An IPP in a neophallus is an acceptable option to achieve rigidity for sexual intercourse. However, this challenging procedure has good reports of patient and partner satisfaction despite significant risks of complications.
期刊介绍:
Therapeutic Advances in Urology delivers the highest quality peer-reviewed articles, reviews, and scholarly comment on pioneering efforts and innovative studies across all areas of urology.
The journal has a strong clinical and pharmacological focus and is aimed at clinicians and researchers in urology, providing a forum in print and online for publishing the highest quality articles in this area. The editors welcome articles of current interest across all areas of urology, including treatment of urological disorders, with a focus on emerging pharmacological therapies.