胸腔镜手术中毛玻璃混浊的超声定位。

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Interactive cardiovascular and thoracic surgery Pub Date : 2022-11-08 DOI:10.1093/icvts/ivac234
Gaetana Messina, Mary Bove, Giovanni Natale, Antonio Noro, Mario Martone, Giorgia Opromolla, Vincenzo Di Filippo, Beatrice Leonardi, Morena Fasano, Rita Polito, Alfonso Fiorelli, Mario Santini, Giovanni Vicidomini
{"title":"胸腔镜手术中毛玻璃混浊的超声定位。","authors":"Gaetana Messina,&nbsp;Mary Bove,&nbsp;Giovanni Natale,&nbsp;Antonio Noro,&nbsp;Mario Martone,&nbsp;Giorgia Opromolla,&nbsp;Vincenzo Di Filippo,&nbsp;Beatrice Leonardi,&nbsp;Morena Fasano,&nbsp;Rita Polito,&nbsp;Alfonso Fiorelli,&nbsp;Mario Santini,&nbsp;Giovanni Vicidomini","doi":"10.1093/icvts/ivac234","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Application of video-assisted thoracoscopy brought lung surgery into the minimally invasive era; the lack of tactile feedback using VATS, remains a disadvantage because surgeons are unable to locate lesions with a finger or device. This study aimed to investigate the effectiveness, the applicability and the utility of intraoperative ultrasound (IU), for the localization of small ground-glass opacity (GGO) lesions in the parenchyma, as a guide in finding their margins in a deflated lung.</p><p><strong>Materials and methods: </strong>We included 15 consecutive patients undergoing diagnostic resection of GGOs via VATS in the Thoracic Surgery Unit of the University of 'Luigi Vanvitelli' of Naples from November 2019 to December 2021. They were under general anaesthesia, when the lung had been collapsed, the probe was placed in the region where the target lesion was thought to reside on the basis of low-dose computed tomography scanning. GGO could be identified their sizes, echo levels and posterior echo was recorded by IU when the lung was completely deflated.</p><p><strong>Results: </strong>We conducted a retrospective single-centre study. All GGOs were identified by IU. The mean size and depth were 14.1 ± 0.5 and 4.8 ± 0.3 mm, respectively. Six (40%) lesions had hyperechoic patterns, 9 (60%) had mixed echogenicity where the hyperechoic patterns were irregularly mixed with hypoechoic patterns. The final diagnoses included 2 (15%) atypical adenomatous hyperplasia; 2 (15%) adenocarcinomas in situ; 3 (23%) minimally invasive adenocarcinomas and 6 (46%) invasive adenocarcinomas.</p><p><strong>Conclusions: </strong>The results of our study showed that IU could safely and effectively detect GGOs.</p>","PeriodicalId":13621,"journal":{"name":"Interactive cardiovascular and thoracic surgery","volume":"35 6","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2022-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749129/pdf/","citationCount":"2","resultStr":"{\"title\":\"Ultrasound location of ground-glass opacity during thoracoscopic surgery.\",\"authors\":\"Gaetana Messina,&nbsp;Mary Bove,&nbsp;Giovanni Natale,&nbsp;Antonio Noro,&nbsp;Mario Martone,&nbsp;Giorgia Opromolla,&nbsp;Vincenzo Di Filippo,&nbsp;Beatrice Leonardi,&nbsp;Morena Fasano,&nbsp;Rita Polito,&nbsp;Alfonso Fiorelli,&nbsp;Mario Santini,&nbsp;Giovanni Vicidomini\",\"doi\":\"10.1093/icvts/ivac234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Application of video-assisted thoracoscopy brought lung surgery into the minimally invasive era; the lack of tactile feedback using VATS, remains a disadvantage because surgeons are unable to locate lesions with a finger or device. This study aimed to investigate the effectiveness, the applicability and the utility of intraoperative ultrasound (IU), for the localization of small ground-glass opacity (GGO) lesions in the parenchyma, as a guide in finding their margins in a deflated lung.</p><p><strong>Materials and methods: </strong>We included 15 consecutive patients undergoing diagnostic resection of GGOs via VATS in the Thoracic Surgery Unit of the University of 'Luigi Vanvitelli' of Naples from November 2019 to December 2021. They were under general anaesthesia, when the lung had been collapsed, the probe was placed in the region where the target lesion was thought to reside on the basis of low-dose computed tomography scanning. GGO could be identified their sizes, echo levels and posterior echo was recorded by IU when the lung was completely deflated.</p><p><strong>Results: </strong>We conducted a retrospective single-centre study. All GGOs were identified by IU. The mean size and depth were 14.1 ± 0.5 and 4.8 ± 0.3 mm, respectively. Six (40%) lesions had hyperechoic patterns, 9 (60%) had mixed echogenicity where the hyperechoic patterns were irregularly mixed with hypoechoic patterns. The final diagnoses included 2 (15%) atypical adenomatous hyperplasia; 2 (15%) adenocarcinomas in situ; 3 (23%) minimally invasive adenocarcinomas and 6 (46%) invasive adenocarcinomas.</p><p><strong>Conclusions: </strong>The results of our study showed that IU could safely and effectively detect GGOs.</p>\",\"PeriodicalId\":13621,\"journal\":{\"name\":\"Interactive cardiovascular and thoracic surgery\",\"volume\":\"35 6\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2022-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749129/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interactive cardiovascular and thoracic surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/icvts/ivac234\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interactive cardiovascular and thoracic surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/icvts/ivac234","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

摘要

目的:视频胸腔镜的应用使肺部手术进入微创时代;使用VATS缺乏触觉反馈仍然是一个缺点,因为外科医生无法用手指或设备定位病变。本研究旨在探讨术中超声(IU)在肺实质小磨玻璃混浊(GGO)病变定位中的有效性、适用性和实用性,并以此作为在肺萎陷中寻找其边缘的指导。材料和方法:我们纳入了2019年11月至2021年12月在那不勒斯“Luigi Vanvitelli”大学胸外科通过VATS进行GGOs诊断性切除术的连续15例患者。他们处于全身麻醉状态,当肺部塌陷时,根据低剂量计算机断层扫描,探针被放置在目标病变所在的区域。在肺完全放气时,可通过超声识别其大小和回声水平,并记录后腔回声。结果:我们进行了一项回顾性单中心研究。所有ggo均通过IU进行鉴定。平均大小为14.1±0.5 mm,深度为4.8±0.3 mm。6例(40%)病变为高回声模式,9例(60%)为混合回声,高回声模式不规则地与低回声模式混合。最终诊断包括2例(15%)非典型性腺瘤性增生;2例(15%)原位腺癌;3例(23%)为微创性腺癌,6例(46%)为浸润性腺癌。结论:本研究结果表明,IU能够安全有效地检测出GGOs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound location of ground-glass opacity during thoracoscopic surgery.

Objectives: Application of video-assisted thoracoscopy brought lung surgery into the minimally invasive era; the lack of tactile feedback using VATS, remains a disadvantage because surgeons are unable to locate lesions with a finger or device. This study aimed to investigate the effectiveness, the applicability and the utility of intraoperative ultrasound (IU), for the localization of small ground-glass opacity (GGO) lesions in the parenchyma, as a guide in finding their margins in a deflated lung.

Materials and methods: We included 15 consecutive patients undergoing diagnostic resection of GGOs via VATS in the Thoracic Surgery Unit of the University of 'Luigi Vanvitelli' of Naples from November 2019 to December 2021. They were under general anaesthesia, when the lung had been collapsed, the probe was placed in the region where the target lesion was thought to reside on the basis of low-dose computed tomography scanning. GGO could be identified their sizes, echo levels and posterior echo was recorded by IU when the lung was completely deflated.

Results: We conducted a retrospective single-centre study. All GGOs were identified by IU. The mean size and depth were 14.1 ± 0.5 and 4.8 ± 0.3 mm, respectively. Six (40%) lesions had hyperechoic patterns, 9 (60%) had mixed echogenicity where the hyperechoic patterns were irregularly mixed with hypoechoic patterns. The final diagnoses included 2 (15%) atypical adenomatous hyperplasia; 2 (15%) adenocarcinomas in situ; 3 (23%) minimally invasive adenocarcinomas and 6 (46%) invasive adenocarcinomas.

Conclusions: The results of our study showed that IU could safely and effectively detect GGOs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interactive cardiovascular and thoracic surgery
Interactive cardiovascular and thoracic surgery CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.30
自引率
0.00%
发文量
292
审稿时长
2-4 weeks
期刊介绍: Interactive CardioVascular and Thoracic Surgery (ICVTS) publishes scientific contributions in the field of cardiovascular and thoracic surgery, covering all aspects of surgery of the heart, vessels and the chest. The journal publishes a range of article types including: Best Evidence Topics; Brief Communications; Case Reports; Original Articles; State-of-the-Art; Work in Progress Report.
期刊最新文献
Local tumour residue after microwave ablation for lung cancer: a case report. Long-term outcomes of papillary muscle relocation anteriorly for functional mitral regurgitation. Postoperative aortic injury caused by a staple line formed during wedge resection of the lung. Surgical management of cardiac cystic echinococcosis in a paediatric patient: a case report. Congenital aortocaval fistula combined with patent ductus arteriosus in an infant: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1