宫颈弹性成像预测早产的诊断准确性:系统回顾和荟萃分析。

IF 1.4 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL Scottish Medical Journal Pub Date : 2023-08-01 Epub Date: 2023-05-31 DOI:10.1177/00369330231178910
Hui Sun, Qifeng Lv, Tingting Liu, Nan Zhang, Fengfeng Shi
{"title":"宫颈弹性成像预测早产的诊断准确性:系统回顾和荟萃分析。","authors":"Hui Sun, Qifeng Lv, Tingting Liu, Nan Zhang, Fengfeng Shi","doi":"10.1177/00369330231178910","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Cervical elastography has been used in pregnant women to diagnose preterm births. However, there is a variability in the measured elasticity parameters and imaging mode used. We evaluated the precision of cervical elastography in identifying preterm births.</p><p><strong>Methods: </strong>Extensive and methodical searches were made in the databases such as Scopus, Embase, Cochrane Library, PubMed Central, Medline, ScienceDirect, and Google Scholar from the inception until November 2022, for studies that report diagnostic accuracy of cervical elastography for preterm deliveries in antenatal women.</p><p><strong>Results: </strong>The pooled sensitivity and specificity value of cervical elastography for preterm deliveries were 82% (95%CI: 73%-89%) and 77% (95%CI: 64%-86%), respectively with area under curve (AUC) of 0.87 (95%CI: 0.72-0.95). The diagnostic odds ratio (DOR) was 15 (95%CI: 8-28), positive likelihood ratio (LRP) was 3.5 (95%CI: 2.3-5.5) and negative likelihood ratio LRN was 0.23 (0.16-0.34). Pooled sensitivity and specificity of shear wave elastography was 88% and 71%, respectively. Pooled sensitivity and specificity of strain elastography was 80% and 79%, respectively. Heterogeneity was significant, as indicated by chi-square test and an I<sup>2</sup> statistic of over 75.</p><p><strong>Conclusions: </strong>Cervical elastography can be used for predicting preterm deliveries with moderate to high level of accuracy.</p>","PeriodicalId":21683,"journal":{"name":"Scottish Medical Journal","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis.\",\"authors\":\"Hui Sun, Qifeng Lv, Tingting Liu, Nan Zhang, Fengfeng Shi\",\"doi\":\"10.1177/00369330231178910\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Cervical elastography has been used in pregnant women to diagnose preterm births. However, there is a variability in the measured elasticity parameters and imaging mode used. We evaluated the precision of cervical elastography in identifying preterm births.</p><p><strong>Methods: </strong>Extensive and methodical searches were made in the databases such as Scopus, Embase, Cochrane Library, PubMed Central, Medline, ScienceDirect, and Google Scholar from the inception until November 2022, for studies that report diagnostic accuracy of cervical elastography for preterm deliveries in antenatal women.</p><p><strong>Results: </strong>The pooled sensitivity and specificity value of cervical elastography for preterm deliveries were 82% (95%CI: 73%-89%) and 77% (95%CI: 64%-86%), respectively with area under curve (AUC) of 0.87 (95%CI: 0.72-0.95). The diagnostic odds ratio (DOR) was 15 (95%CI: 8-28), positive likelihood ratio (LRP) was 3.5 (95%CI: 2.3-5.5) and negative likelihood ratio LRN was 0.23 (0.16-0.34). Pooled sensitivity and specificity of shear wave elastography was 88% and 71%, respectively. Pooled sensitivity and specificity of strain elastography was 80% and 79%, respectively. Heterogeneity was significant, as indicated by chi-square test and an I<sup>2</sup> statistic of over 75.</p><p><strong>Conclusions: </strong>Cervical elastography can be used for predicting preterm deliveries with moderate to high level of accuracy.</p>\",\"PeriodicalId\":21683,\"journal\":{\"name\":\"Scottish Medical Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scottish Medical Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00369330231178910\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scottish Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00369330231178910","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:宫颈弹性成像已被用于孕妇早产的诊断。然而,测量的弹性参数和使用的成像模式存在差异。我们评估了宫颈弹性成像在识别早产方面的精确度:方法:从开始到 2022 年 11 月,我们在 Scopus、Embase、Cochrane Library、PubMed Central、Medline、ScienceDirect 和 Google Scholar 等数据库中进行了广泛而有条理的检索,以寻找报告宫颈弹性成像对产前妇女早产诊断准确性的研究:宫颈弹性成像对早产的合计敏感性和特异性分别为82%(95%CI:73%-89%)和77%(95%CI:64%-86%),曲线下面积(AUC)为0.87(95%CI:0.72-0.95)。诊断几率比(DOR)为 15(95%CI:8-28),阳性似然比(LRP)为 3.5(95%CI:2.3-5.5),阴性似然比 LRN 为 0.23(0.16-0.34)。剪切波弹性成像的汇总敏感性和特异性分别为 88% 和 71%。应变弹性成像的汇总敏感性和特异性分别为 80% 和 79%。根据卡方检验和超过 75 的 I2 统计量,异质性非常明显:结论:宫颈弹性成像可用于预测早产,准确率为中高水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis.

Objective: Cervical elastography has been used in pregnant women to diagnose preterm births. However, there is a variability in the measured elasticity parameters and imaging mode used. We evaluated the precision of cervical elastography in identifying preterm births.

Methods: Extensive and methodical searches were made in the databases such as Scopus, Embase, Cochrane Library, PubMed Central, Medline, ScienceDirect, and Google Scholar from the inception until November 2022, for studies that report diagnostic accuracy of cervical elastography for preterm deliveries in antenatal women.

Results: The pooled sensitivity and specificity value of cervical elastography for preterm deliveries were 82% (95%CI: 73%-89%) and 77% (95%CI: 64%-86%), respectively with area under curve (AUC) of 0.87 (95%CI: 0.72-0.95). The diagnostic odds ratio (DOR) was 15 (95%CI: 8-28), positive likelihood ratio (LRP) was 3.5 (95%CI: 2.3-5.5) and negative likelihood ratio LRN was 0.23 (0.16-0.34). Pooled sensitivity and specificity of shear wave elastography was 88% and 71%, respectively. Pooled sensitivity and specificity of strain elastography was 80% and 79%, respectively. Heterogeneity was significant, as indicated by chi-square test and an I2 statistic of over 75.

Conclusions: Cervical elastography can be used for predicting preterm deliveries with moderate to high level of accuracy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Scottish Medical Journal
Scottish Medical Journal 医学-医学:内科
CiteScore
4.80
自引率
3.70%
发文量
42
审稿时长
>12 weeks
期刊介绍: A unique international information source for the latest news and issues concerning the Scottish medical community. Contributions are drawn from Scotland and its medical institutions, through an array of international authors. In addition to original papers, Scottish Medical Journal publishes commissioned educational review articles, case reports, historical articles, and sponsoring society abstracts.This journal is a member of the Committee on Publications Ethics (COPE).
期刊最新文献
Pancreatic insulinomas: Our 15-year surgical experience. Efficacy and outcomes of a highland prehospital trauma response team. Ribosome-binding protein-1 (RRBP1) expression in prostate carcinomas and its relationship with clinicopathological prognostic factors. A pilot study of performance enhancement coaching for newly appointed urology registrars. Optimising the use of colonoscopy to improve risk stratification for colorectal cancer in symptomatic patients: A decision-curve analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1