铅笔束扫描质子网格治疗大体积肿瘤的治疗计划。

Aditya Halthore, Zachary Fellows, Anh Tran, Curtiland Deville, Jean L Wright, Jeffrey Meyer, Heng Li, Khadija Sheikh
{"title":"铅笔束扫描质子网格治疗大体积肿瘤的治疗计划。","authors":"Aditya Halthore,&nbsp;Zachary Fellows,&nbsp;Anh Tran,&nbsp;Curtiland Deville,&nbsp;Jean L Wright,&nbsp;Jeffrey Meyer,&nbsp;Heng Li,&nbsp;Khadija Sheikh","doi":"10.14338/IJPT-22-00028","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare spatially fractionated radiation therapy (GRID) treatment planning techniques using proton pencil-beam-scanning (PBS) and photon therapy.</p><p><strong>Materials and methods: </strong>PBS and volumetric modulated arc therapy (VMAT) GRID plans were retrospectively generated for 5 patients with bulky tumors. GRID targets were arranged along the long axis of the gross tumor, spaced 2 and 3 cm apart, and treated with a prescription of 18 Gy. PBS plans used 2- to 3-beam multiple-field optimization with robustness evaluation. Dosimetric parameters including peak-to-edge ratio (PEDR), ratio of dose to 90% of the valley to dose to 10% of the peak VPDR(D90/D10), and volume of normal tissue receiving at least 5 Gy (V5) and 10 Gy (V10) were calculated. The peak-to-valley dose ratio (PVDR), VPDR(D90/D10), and organ-at-risk doses were prospectively assessed in 2 patients undergoing PBS-GRID with pretreatment quality assurance computed tomography (QACT) scans.</p><p><strong>Results: </strong>PBS and VMAT GRID plans were generated for 5 patients with bulky tumors. Gross tumor volume values ranged from 826 to 1468 cm<sup>3</sup>. Peak-to-edge ratio for PBS was higher than for VMAT for both spacing scenarios (2-cm spacing, <i>P</i> = .02; 3-cm spacing, <i>P</i> = .01). VPDR(D90/D10) for PBS was higher than for VMAT (2-cm spacing, <i>P</i> = .004; 3-cm spacing, <i>P</i> = .002). Normal tissue V5 was lower for PBS than for VMAT (2-cm spacing, <i>P</i> = .03; 3-cm spacing, <i>P</i> = .02). Normal tissue mean dose was lower with PBS than with VMAT (2-cm spacing, <i>P =</i> .03; 3-cm spacing, <i>P =</i> .02). Two patients treated using PBS GRID and assessed with pretreatment QACT scans demonstrated robust PVDR, VPDR(D90/D10), and organs-at-risk doses.</p><p><strong>Conclusions: </strong>The PEDR was significantly higher for PBS than VMAT plans, indicating lower target edge dose. Normal tissue mean dose was significantly lower with PBS than VMAT. PBS GRID may result in lower normal tissue dose compared with VMAT plans, allowing for further dose escalation in patients with bulky disease.</p>","PeriodicalId":36923,"journal":{"name":"International Journal of Particle Therapy","volume":"9 3","pages":"40-49"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9875826/pdf/","citationCount":"0","resultStr":"{\"title\":\"Treatment Planning of Bulky Tumors Using Pencil Beam Scanning Proton GRID Therapy.\",\"authors\":\"Aditya Halthore,&nbsp;Zachary Fellows,&nbsp;Anh Tran,&nbsp;Curtiland Deville,&nbsp;Jean L Wright,&nbsp;Jeffrey Meyer,&nbsp;Heng Li,&nbsp;Khadija Sheikh\",\"doi\":\"10.14338/IJPT-22-00028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare spatially fractionated radiation therapy (GRID) treatment planning techniques using proton pencil-beam-scanning (PBS) and photon therapy.</p><p><strong>Materials and methods: </strong>PBS and volumetric modulated arc therapy (VMAT) GRID plans were retrospectively generated for 5 patients with bulky tumors. GRID targets were arranged along the long axis of the gross tumor, spaced 2 and 3 cm apart, and treated with a prescription of 18 Gy. PBS plans used 2- to 3-beam multiple-field optimization with robustness evaluation. Dosimetric parameters including peak-to-edge ratio (PEDR), ratio of dose to 90% of the valley to dose to 10% of the peak VPDR(D90/D10), and volume of normal tissue receiving at least 5 Gy (V5) and 10 Gy (V10) were calculated. The peak-to-valley dose ratio (PVDR), VPDR(D90/D10), and organ-at-risk doses were prospectively assessed in 2 patients undergoing PBS-GRID with pretreatment quality assurance computed tomography (QACT) scans.</p><p><strong>Results: </strong>PBS and VMAT GRID plans were generated for 5 patients with bulky tumors. Gross tumor volume values ranged from 826 to 1468 cm<sup>3</sup>. Peak-to-edge ratio for PBS was higher than for VMAT for both spacing scenarios (2-cm spacing, <i>P</i> = .02; 3-cm spacing, <i>P</i> = .01). VPDR(D90/D10) for PBS was higher than for VMAT (2-cm spacing, <i>P</i> = .004; 3-cm spacing, <i>P</i> = .002). Normal tissue V5 was lower for PBS than for VMAT (2-cm spacing, <i>P</i> = .03; 3-cm spacing, <i>P</i> = .02). Normal tissue mean dose was lower with PBS than with VMAT (2-cm spacing, <i>P =</i> .03; 3-cm spacing, <i>P =</i> .02). Two patients treated using PBS GRID and assessed with pretreatment QACT scans demonstrated robust PVDR, VPDR(D90/D10), and organs-at-risk doses.</p><p><strong>Conclusions: </strong>The PEDR was significantly higher for PBS than VMAT plans, indicating lower target edge dose. Normal tissue mean dose was significantly lower with PBS than VMAT. PBS GRID may result in lower normal tissue dose compared with VMAT plans, allowing for further dose escalation in patients with bulky disease.</p>\",\"PeriodicalId\":36923,\"journal\":{\"name\":\"International Journal of Particle Therapy\",\"volume\":\"9 3\",\"pages\":\"40-49\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9875826/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Particle Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14338/IJPT-22-00028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Particle Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14338/IJPT-22-00028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较质子铅笔束扫描(PBS)和光子治疗的空间分割放射治疗(GRID)治疗计划技术。材料和方法:回顾性生成5例体积较大肿瘤的PBS和体积调制电弧治疗(VMAT) GRID方案。GRID靶沿大体肿瘤的长轴排列,间隔2和3cm,并以18 Gy的处方治疗。PBS计划采用2至3束多场优化和鲁棒性评估。计算剂量学参数,包括峰边比(PEDR)、谷值90%的剂量与峰值VPDR 10%的剂量之比(D90/D10)、正常组织接受至少5 Gy (V5)和10 Gy (V10)的体积。前瞻性评估了2例接受PBS-GRID预处理质量保证计算机断层扫描(QACT)的患者的峰谷剂量比(PVDR)、VPDR(D90/D10)和器官危险剂量。结果:生成了5例体积较大肿瘤的PBS和VMAT网格计划。大体肿瘤体积值为826 ~ 1468 cm3。在两种间距情况下,PBS的峰边比均高于VMAT(间距为2 cm, P = 0.02;间距3 cm, P = 0.01)。PBS的VPDR(D90/D10)高于VMAT (2 cm间距,P = 0.004;间距3厘米,P = 0.002)。PBS组正常组织V5低于VMAT组(间隔2 cm, P = .03;间距3 cm, P = 0.02)。PBS组正常组织平均剂量低于VMAT组(间隔2 cm, P = .03;间距3 cm, P = 0.02)。两名患者使用PBS GRID治疗并通过预处理QACT扫描评估,显示出强大的PVDR, VPDR(D90/D10)和器官危险剂量。结论:PBS组PEDR明显高于VMAT组,表明靶边缘剂量较低。PBS的正常组织平均剂量明显低于VMAT。与VMAT计划相比,PBS GRID可能导致较低的正常组织剂量,从而允许对体积较大的疾病患者进一步增加剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Treatment Planning of Bulky Tumors Using Pencil Beam Scanning Proton GRID Therapy.

Purpose: To compare spatially fractionated radiation therapy (GRID) treatment planning techniques using proton pencil-beam-scanning (PBS) and photon therapy.

Materials and methods: PBS and volumetric modulated arc therapy (VMAT) GRID plans were retrospectively generated for 5 patients with bulky tumors. GRID targets were arranged along the long axis of the gross tumor, spaced 2 and 3 cm apart, and treated with a prescription of 18 Gy. PBS plans used 2- to 3-beam multiple-field optimization with robustness evaluation. Dosimetric parameters including peak-to-edge ratio (PEDR), ratio of dose to 90% of the valley to dose to 10% of the peak VPDR(D90/D10), and volume of normal tissue receiving at least 5 Gy (V5) and 10 Gy (V10) were calculated. The peak-to-valley dose ratio (PVDR), VPDR(D90/D10), and organ-at-risk doses were prospectively assessed in 2 patients undergoing PBS-GRID with pretreatment quality assurance computed tomography (QACT) scans.

Results: PBS and VMAT GRID plans were generated for 5 patients with bulky tumors. Gross tumor volume values ranged from 826 to 1468 cm3. Peak-to-edge ratio for PBS was higher than for VMAT for both spacing scenarios (2-cm spacing, P = .02; 3-cm spacing, P = .01). VPDR(D90/D10) for PBS was higher than for VMAT (2-cm spacing, P = .004; 3-cm spacing, P = .002). Normal tissue V5 was lower for PBS than for VMAT (2-cm spacing, P = .03; 3-cm spacing, P = .02). Normal tissue mean dose was lower with PBS than with VMAT (2-cm spacing, P = .03; 3-cm spacing, P = .02). Two patients treated using PBS GRID and assessed with pretreatment QACT scans demonstrated robust PVDR, VPDR(D90/D10), and organs-at-risk doses.

Conclusions: The PEDR was significantly higher for PBS than VMAT plans, indicating lower target edge dose. Normal tissue mean dose was significantly lower with PBS than VMAT. PBS GRID may result in lower normal tissue dose compared with VMAT plans, allowing for further dose escalation in patients with bulky disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Particle Therapy
International Journal of Particle Therapy Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
3.70
自引率
5.90%
发文量
23
审稿时长
20 weeks
期刊最新文献
Impact of COVID-19 Pandemic on Carbon-Ion Radiation Therapy in Japan: A Japanese National Registry Study. Vaginal Mucosal Melanoma Cell Activation in Response to Photon or Carbon Ion Irradiation. Navigating a New Frontier: Evaluating Leadless Pacemakers in Proton Therapy. Cardiac Conduction System as an OAR in Radiation Therapy: Doses to SA/AV Nodes and Their Reduction. Value of Carbon-Ion Radiation Therapy for Breast Cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1