献血者HIV检测的内部质量控制——干管标本是一种具有成本效益的替代品。

IF 0.6 Q4 HEMATOLOGY Asian Journal of Transfusion Science Pub Date : 2022-07-01 Epub Date: 2022-05-26 DOI:10.4103/ajts.ajts_75_21
Ashish Dhoot, Joy J Mammen, Nitty S Mathews, Rajesh Kannangai, Dolly Daniel, S Prasannakumar
{"title":"献血者HIV检测的内部质量控制——干管标本是一种具有成本效益的替代品。","authors":"Ashish Dhoot,&nbsp;Joy J Mammen,&nbsp;Nitty S Mathews,&nbsp;Rajesh Kannangai,&nbsp;Dolly Daniel,&nbsp;S Prasannakumar","doi":"10.4103/ajts.ajts_75_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>An important aspect of ensuring blood safety is the performance of mandatory serological testing for transfusion transmissible infections. The practice of internal quality control (IQC) in blood banks in India is nonuniform, especially the use of third-party materials. Cited reasons are cost, lack of access to control materials, and need for deep-freezers for storage, if prepared in-house.</p><p><strong>Objective: </strong>Validation of dried tube specimen (DTS) from HIV-positive plasma as a low-cost, stable material for use as IQC material in blood banks.</p><p><strong>Methods: </strong>Fresh-frozen plasma (FFP) prepared from four HIV-positive blood-donors were pooled. Equal numbers of seronegative FFPs were pooled. Twenty microlitre aliquots of plasma were made in micro-centrifuge tubes and air-dried overnight at room-temperature. These were stored in 2-8°C refrigerators and tested once weekly for 6 months on multiple platforms with different detection principles: Rapid tests, second-generation enzyme-linked immunosorbent assay (ELISA), fourth-generation ELISA, and fourth-generation Chemiluminescence immunoassay. The protocol was sustained over the next 6 months with decreased testing frequency to study the extended stability of DTS.</p><p><strong>Results: </strong>A total of 139 positive-DTS and 139 negative-DTS were tested with 100% samples showing consistent results on all platforms over 1 year. There was mild deterioration in reaction strengths, which did not interfere in result interpretations.</p><p><strong>Conclusion: </strong>Plasma in form of DTS maintained stability when stored at 2-8°C for 1 year. This provides evidence that DTS can be a modality for the production of cost-effective, stable, in-house control material for resource-restricted countries.</p>","PeriodicalId":42296,"journal":{"name":"Asian Journal of Transfusion Science","volume":"16 2","pages":"231-237"},"PeriodicalIF":0.6000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/90/50/AJTS-16-231.PMC9855207.pdf","citationCount":"0","resultStr":"{\"title\":\"Internal quality control for HIV testing of blood donors - Dried tube specimen as a cost-effective alternative.\",\"authors\":\"Ashish Dhoot,&nbsp;Joy J Mammen,&nbsp;Nitty S Mathews,&nbsp;Rajesh Kannangai,&nbsp;Dolly Daniel,&nbsp;S Prasannakumar\",\"doi\":\"10.4103/ajts.ajts_75_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>An important aspect of ensuring blood safety is the performance of mandatory serological testing for transfusion transmissible infections. The practice of internal quality control (IQC) in blood banks in India is nonuniform, especially the use of third-party materials. Cited reasons are cost, lack of access to control materials, and need for deep-freezers for storage, if prepared in-house.</p><p><strong>Objective: </strong>Validation of dried tube specimen (DTS) from HIV-positive plasma as a low-cost, stable material for use as IQC material in blood banks.</p><p><strong>Methods: </strong>Fresh-frozen plasma (FFP) prepared from four HIV-positive blood-donors were pooled. Equal numbers of seronegative FFPs were pooled. Twenty microlitre aliquots of plasma were made in micro-centrifuge tubes and air-dried overnight at room-temperature. These were stored in 2-8°C refrigerators and tested once weekly for 6 months on multiple platforms with different detection principles: Rapid tests, second-generation enzyme-linked immunosorbent assay (ELISA), fourth-generation ELISA, and fourth-generation Chemiluminescence immunoassay. The protocol was sustained over the next 6 months with decreased testing frequency to study the extended stability of DTS.</p><p><strong>Results: </strong>A total of 139 positive-DTS and 139 negative-DTS were tested with 100% samples showing consistent results on all platforms over 1 year. There was mild deterioration in reaction strengths, which did not interfere in result interpretations.</p><p><strong>Conclusion: </strong>Plasma in form of DTS maintained stability when stored at 2-8°C for 1 year. This provides evidence that DTS can be a modality for the production of cost-effective, stable, in-house control material for resource-restricted countries.</p>\",\"PeriodicalId\":42296,\"journal\":{\"name\":\"Asian Journal of Transfusion Science\",\"volume\":\"16 2\",\"pages\":\"231-237\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/90/50/AJTS-16-231.PMC9855207.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Transfusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ajts.ajts_75_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/5/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajts.ajts_75_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/5/26 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:确保血液安全的一个重要方面是对输血传播性感染进行强制性血清学检测。印度血库内部质量控制(IQC)的做法不统一,尤其是使用第三方材料。引用的原因包括成本、缺乏控制材料以及如果在室内制备,则需要深层冷冻柜进行储存。目的:验证来自HIV阳性血浆的干管标本(DTS)是一种低成本、稳定的材料,可用作血库中的IQC材料。方法:收集4名HIV阳性献血者的新鲜冷冻血浆(FFP)。汇集了相同数量的血清阴性FFP。在微型离心管中制备20微升等分血浆,并在室温下空气干燥过夜。将其储存在2-8°C的冰箱中,并在具有不同检测原理的多个平台上每周检测一次,为期6个月:快速检测、第二代酶联免疫吸附测定(ELISA)、第四代ELISA和第四代化学发光免疫测定。该方案在接下来的6个月内持续有效,降低了测试频率,以研究DTS的扩展稳定性。结果:共对139个阳性DTS和139个阴性DTS进行了测试,100%的样本在所有平台上显示了1年以上的一致结果。反应强度有轻微的下降,这不会干扰结果的解释。结论:DTS形式的血浆在2-8°C下储存1年后保持稳定。这提供了证据,证明DTS可以成为资源有限国家生产成本效益高、稳定、内部控制材料的一种方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Internal quality control for HIV testing of blood donors - Dried tube specimen as a cost-effective alternative.

Background: An important aspect of ensuring blood safety is the performance of mandatory serological testing for transfusion transmissible infections. The practice of internal quality control (IQC) in blood banks in India is nonuniform, especially the use of third-party materials. Cited reasons are cost, lack of access to control materials, and need for deep-freezers for storage, if prepared in-house.

Objective: Validation of dried tube specimen (DTS) from HIV-positive plasma as a low-cost, stable material for use as IQC material in blood banks.

Methods: Fresh-frozen plasma (FFP) prepared from four HIV-positive blood-donors were pooled. Equal numbers of seronegative FFPs were pooled. Twenty microlitre aliquots of plasma were made in micro-centrifuge tubes and air-dried overnight at room-temperature. These were stored in 2-8°C refrigerators and tested once weekly for 6 months on multiple platforms with different detection principles: Rapid tests, second-generation enzyme-linked immunosorbent assay (ELISA), fourth-generation ELISA, and fourth-generation Chemiluminescence immunoassay. The protocol was sustained over the next 6 months with decreased testing frequency to study the extended stability of DTS.

Results: A total of 139 positive-DTS and 139 negative-DTS were tested with 100% samples showing consistent results on all platforms over 1 year. There was mild deterioration in reaction strengths, which did not interfere in result interpretations.

Conclusion: Plasma in form of DTS maintained stability when stored at 2-8°C for 1 year. This provides evidence that DTS can be a modality for the production of cost-effective, stable, in-house control material for resource-restricted countries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
56
审稿时长
44 weeks
期刊最新文献
A method for selecting P antigen-negative red cell units for patients with paroxysmal cold hemoglobinuria. A review of issues and challenges of implementation of patient blood management. A study on beneficial impact of the use of medium-molecular-weight hydroxyethyl starch in granulocyte apheresis using continuous-flow cell separator Spectra Optia: A retrospective single-center study at a tertiary care oncology center. Aweak phenotype associated with novel ABO*A allele variant c.106delinsGG. Antioxidative effects of α-tocopherol on stored human red blood cell units.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1