Kang Hyeon Kim, Kyung Wook Wee, CheonJung Kim, Don Hur, Jeong Hoon Lee, Yong Kyoung Yoo
{"title":"快速和低成本,和一次性的电子传感器使用扩展门场效应晶体管心脏肌钙蛋白I检测。","authors":"Kang Hyeon Kim, Kyung Wook Wee, CheonJung Kim, Don Hur, Jeong Hoon Lee, Yong Kyoung Yoo","doi":"10.1007/s13534-022-00219-x","DOIUrl":null,"url":null,"abstract":"<p><p>Field effect transistor (FET) biosensor is based on metal oxide field effect transistor that is gated by changes in the surface charges induced the reaction of biomolecules. In most cases of FET biosensor, FET biosensor is not being reused after the reaction; therefore, it is an important concept of investigate the biosensor with simplicity, cheap and reusability. However, the conventional cardiac troponin I (cTnI) sensing technique is inadequate owing to its low sensitivity and high operational time and cost. In this study, we developed a rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor (EGFET) to detect cTnI, as a key biomarker for myocardiac infarction. We first investigated pH sensing characteristics according to the pH level, which provided a logarithmically linear sensitivity in the pH sensing buffer solution of approximately 57.9 mV/pH. Subsequently, we prepared a cTnI sample and monitored the reaction between cTnI and cTnI antibodies through the changes in the drain current and transfer curves. Our results showed that the EGFET biosensor could successfully detect the cTnI levels as well as the pH with low-cost and rapid detection.</p>","PeriodicalId":46898,"journal":{"name":"Biomedical Engineering Letters","volume":"12 2","pages":"197-203"},"PeriodicalIF":3.2000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9046487/pdf/13534_2022_Article_219.pdf","citationCount":"3","resultStr":"{\"title\":\"Rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor for cardiac troponin I detection.\",\"authors\":\"Kang Hyeon Kim, Kyung Wook Wee, CheonJung Kim, Don Hur, Jeong Hoon Lee, Yong Kyoung Yoo\",\"doi\":\"10.1007/s13534-022-00219-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Field effect transistor (FET) biosensor is based on metal oxide field effect transistor that is gated by changes in the surface charges induced the reaction of biomolecules. In most cases of FET biosensor, FET biosensor is not being reused after the reaction; therefore, it is an important concept of investigate the biosensor with simplicity, cheap and reusability. However, the conventional cardiac troponin I (cTnI) sensing technique is inadequate owing to its low sensitivity and high operational time and cost. In this study, we developed a rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor (EGFET) to detect cTnI, as a key biomarker for myocardiac infarction. We first investigated pH sensing characteristics according to the pH level, which provided a logarithmically linear sensitivity in the pH sensing buffer solution of approximately 57.9 mV/pH. Subsequently, we prepared a cTnI sample and monitored the reaction between cTnI and cTnI antibodies through the changes in the drain current and transfer curves. Our results showed that the EGFET biosensor could successfully detect the cTnI levels as well as the pH with low-cost and rapid detection.</p>\",\"PeriodicalId\":46898,\"journal\":{\"name\":\"Biomedical Engineering Letters\",\"volume\":\"12 2\",\"pages\":\"197-203\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9046487/pdf/13534_2022_Article_219.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Engineering Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s13534-022-00219-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Engineering Letters","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13534-022-00219-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor for cardiac troponin I detection.
Field effect transistor (FET) biosensor is based on metal oxide field effect transistor that is gated by changes in the surface charges induced the reaction of biomolecules. In most cases of FET biosensor, FET biosensor is not being reused after the reaction; therefore, it is an important concept of investigate the biosensor with simplicity, cheap and reusability. However, the conventional cardiac troponin I (cTnI) sensing technique is inadequate owing to its low sensitivity and high operational time and cost. In this study, we developed a rapid and low-cost, and disposable electrical sensor using an extended gate field-effect transistor (EGFET) to detect cTnI, as a key biomarker for myocardiac infarction. We first investigated pH sensing characteristics according to the pH level, which provided a logarithmically linear sensitivity in the pH sensing buffer solution of approximately 57.9 mV/pH. Subsequently, we prepared a cTnI sample and monitored the reaction between cTnI and cTnI antibodies through the changes in the drain current and transfer curves. Our results showed that the EGFET biosensor could successfully detect the cTnI levels as well as the pH with low-cost and rapid detection.
期刊介绍:
Biomedical Engineering Letters (BMEL) aims to present the innovative experimental science and technological development in the biomedical field as well as clinical application of new development. The article must contain original biomedical engineering content, defined as development, theoretical analysis, and evaluation/validation of a new technique. BMEL publishes the following types of papers: original articles, review articles, editorials, and letters to the editor. All the papers are reviewed in single-blind fashion.