Franco Franchignoni, Andrea Giordano, Linda Rinaldo, Murat Kara, Levent Özçakar
{"title":"使用测试信息功能评估短物理性能电池的个人水平测量精度。","authors":"Franco Franchignoni, Andrea Giordano, Linda Rinaldo, Murat Kara, Levent Özçakar","doi":"10.1097/MRR.0000000000000557","DOIUrl":null,"url":null,"abstract":"<p><p>The Short Physical Performance Battery (SPPB) is a commonly used tool to assess lower extremity function, composed of three assessments (standing balance, gait speed, and chair stand). While its validity for group-level decisions has been positively demonstrated, the measurement precision at the individual level needs more clarification. We aimed to examine the SPPB's psychometric characteristics including its conditional measurement precision with Rasch methods in a sample of elderly patients admitted to cardiac rehabilitation. We analyzed prospectively collected SPPB data from 637 patients aged ≥75 years, admitted to our cardiac rehabilitation department (January 2018-July 2019). After classical Rasch analysis, we calculated the test information function to examine the measurement precision of the SPPB along the score continuum. The mean SPPB score was 6.3 points (SD 3.4) (potential range 0-12). Our results confirmed the SPPB unidimensionality (variance attributable to the main factor: 84.8%), appropriate functioning of rating scale categories, internal construct validity (infit and outfit mean-square statistics: 0.90-1.09), and no item local dependence (residual correlations <0.2). However, the measurement precision at the individual level was quite limited (SE > 0.94 logits): the confidence intervals for true scores were, at best, about one-third of the score range (four points). This limited measurement precision increases the risk of inappropriate clinical decisions about individuals in diagnostic classification or change assessment. Therefore, further research of high methodological quality is warranted on this point. Moreover, a clearer distinction between group-level vs. individual-level indicators of change is necessary.</p>","PeriodicalId":14301,"journal":{"name":"International Journal of Rehabilitation Research","volume":"46 1","pages":"46-52"},"PeriodicalIF":1.5000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Assessing individual-level measurement precision of the Short Physical Performance Battery using the test information function.\",\"authors\":\"Franco Franchignoni, Andrea Giordano, Linda Rinaldo, Murat Kara, Levent Özçakar\",\"doi\":\"10.1097/MRR.0000000000000557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Short Physical Performance Battery (SPPB) is a commonly used tool to assess lower extremity function, composed of three assessments (standing balance, gait speed, and chair stand). While its validity for group-level decisions has been positively demonstrated, the measurement precision at the individual level needs more clarification. We aimed to examine the SPPB's psychometric characteristics including its conditional measurement precision with Rasch methods in a sample of elderly patients admitted to cardiac rehabilitation. We analyzed prospectively collected SPPB data from 637 patients aged ≥75 years, admitted to our cardiac rehabilitation department (January 2018-July 2019). After classical Rasch analysis, we calculated the test information function to examine the measurement precision of the SPPB along the score continuum. The mean SPPB score was 6.3 points (SD 3.4) (potential range 0-12). Our results confirmed the SPPB unidimensionality (variance attributable to the main factor: 84.8%), appropriate functioning of rating scale categories, internal construct validity (infit and outfit mean-square statistics: 0.90-1.09), and no item local dependence (residual correlations <0.2). However, the measurement precision at the individual level was quite limited (SE > 0.94 logits): the confidence intervals for true scores were, at best, about one-third of the score range (four points). This limited measurement precision increases the risk of inappropriate clinical decisions about individuals in diagnostic classification or change assessment. Therefore, further research of high methodological quality is warranted on this point. Moreover, a clearer distinction between group-level vs. individual-level indicators of change is necessary.</p>\",\"PeriodicalId\":14301,\"journal\":{\"name\":\"International Journal of Rehabilitation Research\",\"volume\":\"46 1\",\"pages\":\"46-52\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Rehabilitation Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MRR.0000000000000557\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Rehabilitation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MRR.0000000000000557","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
Assessing individual-level measurement precision of the Short Physical Performance Battery using the test information function.
The Short Physical Performance Battery (SPPB) is a commonly used tool to assess lower extremity function, composed of three assessments (standing balance, gait speed, and chair stand). While its validity for group-level decisions has been positively demonstrated, the measurement precision at the individual level needs more clarification. We aimed to examine the SPPB's psychometric characteristics including its conditional measurement precision with Rasch methods in a sample of elderly patients admitted to cardiac rehabilitation. We analyzed prospectively collected SPPB data from 637 patients aged ≥75 years, admitted to our cardiac rehabilitation department (January 2018-July 2019). After classical Rasch analysis, we calculated the test information function to examine the measurement precision of the SPPB along the score continuum. The mean SPPB score was 6.3 points (SD 3.4) (potential range 0-12). Our results confirmed the SPPB unidimensionality (variance attributable to the main factor: 84.8%), appropriate functioning of rating scale categories, internal construct validity (infit and outfit mean-square statistics: 0.90-1.09), and no item local dependence (residual correlations <0.2). However, the measurement precision at the individual level was quite limited (SE > 0.94 logits): the confidence intervals for true scores were, at best, about one-third of the score range (four points). This limited measurement precision increases the risk of inappropriate clinical decisions about individuals in diagnostic classification or change assessment. Therefore, further research of high methodological quality is warranted on this point. Moreover, a clearer distinction between group-level vs. individual-level indicators of change is necessary.
期刊介绍:
International Journal of Rehabilitation Research is a quarterly, peer-reviewed, interdisciplinary forum for the publication of research into functioning, disability and contextual factors experienced by persons of all ages in both developed and developing societies. The wealth of information offered makes the journal a valuable resource for researchers, practitioners, and administrators in such fields as rehabilitation medicine, outcome measurement nursing, social and vocational rehabilitation/case management, return to work, special education, social policy, social work and social welfare, sociology, psychology, psychiatry assistive technology and environmental factors/disability. Areas of interest include functioning and disablement throughout the life cycle; rehabilitation programmes for persons with physical, sensory, mental and developmental disabilities; measurement of functioning and disability; special education and vocational rehabilitation; equipment access and transportation; information technology; independent living; consumer, legal, economic and sociopolitical aspects of functioning, disability and contextual factors.