利用共聚焦扫描激光系统反射图像测量黄斑色素光密度。

IF 2.1 3区 医学 Q2 OPHTHALMOLOGY Japanese Journal of Ophthalmology Pub Date : 2024-01-01 Epub Date: 2023-11-15 DOI:10.1007/s10384-023-01031-5
Hirofumi Morita, Itsuka Matsushita, Yoshihisa Fujino, Akira Obana, Hiroyuki Kondo
{"title":"利用共聚焦扫描激光系统反射图像测量黄斑色素光密度。","authors":"Hirofumi Morita, Itsuka Matsushita, Yoshihisa Fujino, Akira Obana, Hiroyuki Kondo","doi":"10.1007/s10384-023-01031-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop a method to measure the macular pigment optical density (MPOD) using scanning laser ophthalmoscopic images in young adults and children.</p><p><strong>Study design: </strong>Cross-sectional study.</p><p><strong>Methods: </strong>Blue light reflectance fundus images of 32 healthy subjects were used. A profile of the linear reflectance changes across the center of the fovea on a grayscale fundus image was generated. The ratio of the macula-to-periphery reflection was designated as the peak value of the MPOD (MPOD<sub>[FR]</sub>) based on established fundamentals. In the MPOD profile, the basal width of the pixels at MPOD < 0 (wMP) and width at one-half value of the MPOD<sub>[FR]</sub> (wMP<sub>0.5</sub>) were determined. The MOPD at eccentricity of 0.5° was measured by heterochromatic flicker photometry (MPOD<sub>[HFP]</sub>), and the correlation between the MPOD<sub>[FR]</sub> and MPOD<sub>[HFP]</sub> was evaluated.</p><p><strong>Results: </strong>The MPOD<sub>[FR]</sub> ranged from 0.17 to 0.73 with a mean of 0.40 ± 0.13. The wMP ranged from 88 to 173 pixels with a mean of 121.7 ± 24.2 pixels, and the wMP<sub>0.5</sub> ranged from 38 to 83 pixels with a mean of 54.1 ± 10.3 pixels. A significant correlation was found between the MPOD<sub>[FR]</sub> and MPOD<sub>[HFP]</sub> (r = 0.41, P = 0.02).</p><p><strong>Conclusions: </strong>This simplified method can provide accurate and reliable values of the MPOD comparable to heterochromatic flicker photometry. Obtaining the fundus images in this fast and easy way should be suitable for children thus enabling clinicians to determine the MPODs for children.</p>","PeriodicalId":14563,"journal":{"name":"Japanese Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring macular pigment optical density using reflective images of confocal scanning laser system.\",\"authors\":\"Hirofumi Morita, Itsuka Matsushita, Yoshihisa Fujino, Akira Obana, Hiroyuki Kondo\",\"doi\":\"10.1007/s10384-023-01031-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To develop a method to measure the macular pigment optical density (MPOD) using scanning laser ophthalmoscopic images in young adults and children.</p><p><strong>Study design: </strong>Cross-sectional study.</p><p><strong>Methods: </strong>Blue light reflectance fundus images of 32 healthy subjects were used. A profile of the linear reflectance changes across the center of the fovea on a grayscale fundus image was generated. The ratio of the macula-to-periphery reflection was designated as the peak value of the MPOD (MPOD<sub>[FR]</sub>) based on established fundamentals. In the MPOD profile, the basal width of the pixels at MPOD < 0 (wMP) and width at one-half value of the MPOD<sub>[FR]</sub> (wMP<sub>0.5</sub>) were determined. The MOPD at eccentricity of 0.5° was measured by heterochromatic flicker photometry (MPOD<sub>[HFP]</sub>), and the correlation between the MPOD<sub>[FR]</sub> and MPOD<sub>[HFP]</sub> was evaluated.</p><p><strong>Results: </strong>The MPOD<sub>[FR]</sub> ranged from 0.17 to 0.73 with a mean of 0.40 ± 0.13. The wMP ranged from 88 to 173 pixels with a mean of 121.7 ± 24.2 pixels, and the wMP<sub>0.5</sub> ranged from 38 to 83 pixels with a mean of 54.1 ± 10.3 pixels. A significant correlation was found between the MPOD<sub>[FR]</sub> and MPOD<sub>[HFP]</sub> (r = 0.41, P = 0.02).</p><p><strong>Conclusions: </strong>This simplified method can provide accurate and reliable values of the MPOD comparable to heterochromatic flicker photometry. Obtaining the fundus images in this fast and easy way should be suitable for children thus enabling clinicians to determine the MPODs for children.</p>\",\"PeriodicalId\":14563,\"journal\":{\"name\":\"Japanese Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10384-023-01031-5\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10384-023-01031-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:建立一种利用扫描式激光检眼镜图像测量青少年和儿童黄斑色素光密度(MPOD)的方法。研究设计:横断面研究。方法:采用32例正常人眼底蓝光反射图像。在灰度眼底图像上生成了沿中央凹中心的线性反射率变化轮廓。根据已建立的基本原理,将黄斑与周围反射的比值指定为MPOD的峰值(MPOD[FR])。在MPOD剖面中,确定了MPOD [FR]处像素的基底宽度(wMP0.5)。采用异色闪烁光度法(heterochromatic flicker photometry, MPOD[HFP])测量偏心率0.5°时的MOPD,并评价MPOD[FR]与MPOD[HFP]的相关性。结果:MPOD[FR]范围为0.17 ~ 0.73,平均值为0.40±0.13。wMP范围为88 ~ 173,平均为121.7±24.2;wMP0.5范围为38 ~ 83,平均为54.1±10.3。MPOD[FR]与MPOD[HFP]之间存在显著相关性(r = 0.41, P = 0.02)。结论:该简化方法可提供与异色闪烁光度法相当的准确可靠的MPOD值。以这种快速简便的方法获得眼底图像应该适合儿童,从而使临床医生能够确定儿童的MPODs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measuring macular pigment optical density using reflective images of confocal scanning laser system.

Purpose: To develop a method to measure the macular pigment optical density (MPOD) using scanning laser ophthalmoscopic images in young adults and children.

Study design: Cross-sectional study.

Methods: Blue light reflectance fundus images of 32 healthy subjects were used. A profile of the linear reflectance changes across the center of the fovea on a grayscale fundus image was generated. The ratio of the macula-to-periphery reflection was designated as the peak value of the MPOD (MPOD[FR]) based on established fundamentals. In the MPOD profile, the basal width of the pixels at MPOD < 0 (wMP) and width at one-half value of the MPOD[FR] (wMP0.5) were determined. The MOPD at eccentricity of 0.5° was measured by heterochromatic flicker photometry (MPOD[HFP]), and the correlation between the MPOD[FR] and MPOD[HFP] was evaluated.

Results: The MPOD[FR] ranged from 0.17 to 0.73 with a mean of 0.40 ± 0.13. The wMP ranged from 88 to 173 pixels with a mean of 121.7 ± 24.2 pixels, and the wMP0.5 ranged from 38 to 83 pixels with a mean of 54.1 ± 10.3 pixels. A significant correlation was found between the MPOD[FR] and MPOD[HFP] (r = 0.41, P = 0.02).

Conclusions: This simplified method can provide accurate and reliable values of the MPOD comparable to heterochromatic flicker photometry. Obtaining the fundus images in this fast and easy way should be suitable for children thus enabling clinicians to determine the MPODs for children.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
8.30%
发文量
65
审稿时长
6-12 weeks
期刊介绍: The Japanese Journal of Ophthalmology (JJO) was inaugurated in 1957 as a quarterly journal published in English by the Ophthalmology Department of the University of Tokyo, with the aim of disseminating the achievements of Japanese ophthalmologists worldwide. JJO remains the only Japanese ophthalmology journal published in English. In 1997, the Japanese Ophthalmological Society assumed the responsibility for publishing the Japanese Journal of Ophthalmology as its official English-language publication. Currently the journal is published bimonthly and accepts papers from authors worldwide. JJO has become an international interdisciplinary forum for the publication of basic science and clinical research papers.
期刊最新文献
Choroidal thickness in macular, nasal midperiphery, and temporal midperiphery regions and its relationship with axial length and refractive error. Usage status of biologics for the chronic treatment of optic neuritis in neuromyelitis optica spectrum disorders in Japan. Epiretinal membrane: an overview and update. Improvements in visual function early after cataract surgery in eyes implanted with multifocal intraocular lenses. One-year results of trabeculectomy with emphasis on the effect of patients' age.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1