{"title":"Cz-C3/C4与C3-C4蒙太奇在经颅面部运动诱发电位监测中保护外周刺激的比较","authors":"Ryuta Matsuoka, Naoya Hamada, Nobuyuki Nishimura, Takaaki Mitsui, Yuki Shiraishi, Hiromichi Hayami, Kenji Fukutome, Rinsei Tei, Yasushi Shin, Shuta Aketa, Daizo Kato, Takashi Kita, Yasushi Motoyama","doi":"10.1097/WNP.0000000000001024","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In facial motor-evoked potential monitoring, efforts to reduce peripheral stimulation are necessary because it can cause false-negatives. The effects of peripheral stimulation on Cz-C3/C4 and C3-C4 montages were compared.</p><p><strong>Methods: </strong>Facial motor-evoked potentials were recorded from bilateral orbicularis oculi (Oculi) and oris (Oris) muscles. The double-train approach combining single-pulse and five-train pulse stimulation was used to determine the effect of peripheral stimulation. If the five-train pulse produced a significant waveform, it was defined as \"total success.\" In total success cases, \"true success\" was defined as a case in which no waveform appeared after the single pulse at the threshold level of the five-train pulse. The total and true success rates and the threshold value of Oculi and Oris were compared between Cz-C3/C4 and C3-C4 montages.</p><p><strong>Results: </strong>Thirty-six muscles each of Oculi and Oris of 18 patients were used for the analysis. True success was more likely to be obtained by the Cz-C3/C4 montage than the C3-C4 montage in Oculi (42% vs. 22%, p = 0.039). Both Oculi and Oris had higher thresholds to elicit facial motor-evoked potentials with the Cz-C3/C4 montage (Oculi: 101.7 vs. 71.4 mA, p = 0.038; Oris: 94.8 vs. 73.1 mA, p = 0.016).</p><p><strong>Conclusions: </strong>Cz-C3/4 montage is more effective at reducing peripheral stimulation compared with the C3-4 montage. This effect was primarily seen in the orbicularis oculi muscle. It should be noted that the Cz-C3/C4 montage has a higher threshold than the C3-C4 montage in facial muscles. In facial motor-evoked potential monitoring, the Cz-C3/C4 montage may be more suitable to eliminate peripheral stimulation.</p>","PeriodicalId":15516,"journal":{"name":"Journal of Clinical Neurophysiology","volume":" ","pages":"565-569"},"PeriodicalIF":2.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison Between Cz-C3/C4 and C3-C4 Montages to Protect Against Peripheral Stimulation in Transcranial Facial Motor-Evoked Potential Monitoring.\",\"authors\":\"Ryuta Matsuoka, Naoya Hamada, Nobuyuki Nishimura, Takaaki Mitsui, Yuki Shiraishi, Hiromichi Hayami, Kenji Fukutome, Rinsei Tei, Yasushi Shin, Shuta Aketa, Daizo Kato, Takashi Kita, Yasushi Motoyama\",\"doi\":\"10.1097/WNP.0000000000001024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>In facial motor-evoked potential monitoring, efforts to reduce peripheral stimulation are necessary because it can cause false-negatives. The effects of peripheral stimulation on Cz-C3/C4 and C3-C4 montages were compared.</p><p><strong>Methods: </strong>Facial motor-evoked potentials were recorded from bilateral orbicularis oculi (Oculi) and oris (Oris) muscles. The double-train approach combining single-pulse and five-train pulse stimulation was used to determine the effect of peripheral stimulation. If the five-train pulse produced a significant waveform, it was defined as \\\"total success.\\\" In total success cases, \\\"true success\\\" was defined as a case in which no waveform appeared after the single pulse at the threshold level of the five-train pulse. The total and true success rates and the threshold value of Oculi and Oris were compared between Cz-C3/C4 and C3-C4 montages.</p><p><strong>Results: </strong>Thirty-six muscles each of Oculi and Oris of 18 patients were used for the analysis. True success was more likely to be obtained by the Cz-C3/C4 montage than the C3-C4 montage in Oculi (42% vs. 22%, p = 0.039). Both Oculi and Oris had higher thresholds to elicit facial motor-evoked potentials with the Cz-C3/C4 montage (Oculi: 101.7 vs. 71.4 mA, p = 0.038; Oris: 94.8 vs. 73.1 mA, p = 0.016).</p><p><strong>Conclusions: </strong>Cz-C3/4 montage is more effective at reducing peripheral stimulation compared with the C3-4 montage. This effect was primarily seen in the orbicularis oculi muscle. It should be noted that the Cz-C3/C4 montage has a higher threshold than the C3-C4 montage in facial muscles. In facial motor-evoked potential monitoring, the Cz-C3/C4 montage may be more suitable to eliminate peripheral stimulation.</p>\",\"PeriodicalId\":15516,\"journal\":{\"name\":\"Journal of Clinical Neurophysiology\",\"volume\":\" \",\"pages\":\"565-569\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Neurophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/WNP.0000000000001024\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WNP.0000000000001024","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
在面部运动诱发电位监测中,努力减少周围刺激是必要的,因为它可能导致假阴性。比较外周刺激对Cz-C3/C4和C3-C4蒙太奇的影响。方法:记录双侧眼轮匝肌和口肌的面部运动诱发电位。采用双列法结合单脉冲和五列脉冲刺激来确定外周刺激的效果。如果五列脉冲产生了显著的波形,就被定义为“完全成功”。在总成功案例中,“真正成功”定义为在五列脉冲的阈值水平下,单脉冲后没有波形出现。比较Cz-C3/C4蒙太奇和C3-C4蒙太奇对Oculi和Oris的总成功率、真实成功率和阈值。结果:对18例患者的眼、口肌各36块进行分析。Cz-C3/C4蒙太奇比C3-C4蒙太奇在Oculi中获得真正成功的可能性更大(42%比22%,p = 0.039)。Oculi和Oris在Cz-C3/C4蒙太奇下诱发面部运动诱发电位的阈值较高(Oculi: 101.7 mA vs. 71.4 mA, p = 0.038;Oris: 94.8 vs. 73.1 mA, p = 0.016)。结论:Cz-C3/4蒙太奇比C3-4蒙太奇更能有效减少外周刺激。这种作用主要见于眼轮匝肌。需要注意的是,Cz-C3/C4蒙太奇的面部肌肉阈值高于C3-C4蒙太奇。在面部运动诱发电位监测中,Cz-C3/C4蒙太奇可能更适合消除外周刺激。
Comparison Between Cz-C3/C4 and C3-C4 Montages to Protect Against Peripheral Stimulation in Transcranial Facial Motor-Evoked Potential Monitoring.
Introduction: In facial motor-evoked potential monitoring, efforts to reduce peripheral stimulation are necessary because it can cause false-negatives. The effects of peripheral stimulation on Cz-C3/C4 and C3-C4 montages were compared.
Methods: Facial motor-evoked potentials were recorded from bilateral orbicularis oculi (Oculi) and oris (Oris) muscles. The double-train approach combining single-pulse and five-train pulse stimulation was used to determine the effect of peripheral stimulation. If the five-train pulse produced a significant waveform, it was defined as "total success." In total success cases, "true success" was defined as a case in which no waveform appeared after the single pulse at the threshold level of the five-train pulse. The total and true success rates and the threshold value of Oculi and Oris were compared between Cz-C3/C4 and C3-C4 montages.
Results: Thirty-six muscles each of Oculi and Oris of 18 patients were used for the analysis. True success was more likely to be obtained by the Cz-C3/C4 montage than the C3-C4 montage in Oculi (42% vs. 22%, p = 0.039). Both Oculi and Oris had higher thresholds to elicit facial motor-evoked potentials with the Cz-C3/C4 montage (Oculi: 101.7 vs. 71.4 mA, p = 0.038; Oris: 94.8 vs. 73.1 mA, p = 0.016).
Conclusions: Cz-C3/4 montage is more effective at reducing peripheral stimulation compared with the C3-4 montage. This effect was primarily seen in the orbicularis oculi muscle. It should be noted that the Cz-C3/C4 montage has a higher threshold than the C3-C4 montage in facial muscles. In facial motor-evoked potential monitoring, the Cz-C3/C4 montage may be more suitable to eliminate peripheral stimulation.
期刊介绍:
The Journal of Clinical Neurophysiology features both topical reviews and original research in both central and peripheral neurophysiology, as related to patient evaluation and treatment.
Official Journal of the American Clinical Neurophysiology Society.