Nasir Ahmad, Hafsah Muhammad, Ishaq N Khan, Sami Siraj, Sajjad Ahmad, Muhammad Zakria, Asif Ali, Yasar Mehmood Yousafzai
{"title":"Pcr池检测在巴基斯坦筛查Covid-19感染的有效性","authors":"Nasir Ahmad, Hafsah Muhammad, Ishaq N Khan, Sami Siraj, Sajjad Ahmad, Muhammad Zakria, Asif Ali, Yasar Mehmood Yousafzai","doi":"10.55519/JAMC-04-10294","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.</p><p><strong>Methods: </strong>After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.</p><p><strong>Results: </strong>1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.</p><p><strong>Conclusions: </strong>Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.</p>","PeriodicalId":15141,"journal":{"name":"Journal of Ayub Medical College, Abbottabad : JAMC","volume":"34 4","pages":"817-822"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness Of Pcr Pool Testing For Screening Of Covid-19 Infection In Pakistan.\",\"authors\":\"Nasir Ahmad, Hafsah Muhammad, Ishaq N Khan, Sami Siraj, Sajjad Ahmad, Muhammad Zakria, Asif Ali, Yasar Mehmood Yousafzai\",\"doi\":\"10.55519/JAMC-04-10294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.</p><p><strong>Methods: </strong>After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.</p><p><strong>Results: </strong>1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.</p><p><strong>Conclusions: </strong>Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.</p>\",\"PeriodicalId\":15141,\"journal\":{\"name\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"volume\":\"34 4\",\"pages\":\"817-822\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55519/JAMC-04-10294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ayub Medical College, Abbottabad : JAMC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55519/JAMC-04-10294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Effectiveness Of Pcr Pool Testing For Screening Of Covid-19 Infection In Pakistan.
Background: We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.
Methods: After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.
Results: 1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.
Conclusions: Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.