Pcr池检测在巴基斯坦筛查Covid-19感染的有效性

Nasir Ahmad, Hafsah Muhammad, Ishaq N Khan, Sami Siraj, Sajjad Ahmad, Muhammad Zakria, Asif Ali, Yasar Mehmood Yousafzai
{"title":"Pcr池检测在巴基斯坦筛查Covid-19感染的有效性","authors":"Nasir Ahmad,&nbsp;Hafsah Muhammad,&nbsp;Ishaq N Khan,&nbsp;Sami Siraj,&nbsp;Sajjad Ahmad,&nbsp;Muhammad Zakria,&nbsp;Asif Ali,&nbsp;Yasar Mehmood Yousafzai","doi":"10.55519/JAMC-04-10294","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.</p><p><strong>Methods: </strong>After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.</p><p><strong>Results: </strong>1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.</p><p><strong>Conclusions: </strong>Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.</p>","PeriodicalId":15141,"journal":{"name":"Journal of Ayub Medical College, Abbottabad : JAMC","volume":"34 4","pages":"817-822"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness Of Pcr Pool Testing For Screening Of Covid-19 Infection In Pakistan.\",\"authors\":\"Nasir Ahmad,&nbsp;Hafsah Muhammad,&nbsp;Ishaq N Khan,&nbsp;Sami Siraj,&nbsp;Sajjad Ahmad,&nbsp;Muhammad Zakria,&nbsp;Asif Ali,&nbsp;Yasar Mehmood Yousafzai\",\"doi\":\"10.55519/JAMC-04-10294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.</p><p><strong>Methods: </strong>After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.</p><p><strong>Results: </strong>1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.</p><p><strong>Conclusions: </strong>Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.</p>\",\"PeriodicalId\":15141,\"journal\":{\"name\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"volume\":\"34 4\",\"pages\":\"817-822\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55519/JAMC-04-10294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ayub Medical College, Abbottabad : JAMC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55519/JAMC-04-10294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:我们检验了迷你池PCR检测在CoViD-19筛查中合理使用PCR耗材的效用。方法:经过中试,选取3个样本量。进行一步RT-PCR。对小型池中具有COVID基因扩增的样本进行单独检测。结果:516个小池中1548个样本检测,396个小池为阴性,120个为阳性。经个别检测,110个样本呈阳性,9个样本不确定。共进行876次PCR反应,检测1548份样品,节省43% PCR试剂。低流行率的中心节省了大部分试剂(50%),而高流行率的中心节省了更多的测试反应。个别样品的测试导致报告延迟。结论:池化可以增加实验室容量,然而,池化延迟结果并导致样品降解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effectiveness Of Pcr Pool Testing For Screening Of Covid-19 Infection In Pakistan.

Background: We tested the utility of mini-pool PCR testing for the rational use of PCR consumables in screening for CoViD-19.

Methods: After pilot experiments, 3-samples pool size was selected. One step RT-PCR was performed. The samples in the mini-pool having COVID gene amplification were tested individually.

Results: 1548 samples tested in 516 mini-pools resulted 396 mini-pools as negative and 120 as positive. Upon individual testing, 110 samples tested positive and 9 were inconclusive. 876 PCR reactions were performed to test 1548 samples, saving 43% PCR reagents. Centres with low prevalence resulted in most saving on reagents (50%), while centres with high prevalence resulted in more test reactions. Testing of individual samples resulted in delays in reporting.

Conclusions: Pooling can increase lab capacity, however, pooling delays results and cause degradation of samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
304
期刊最新文献
REFRACTORY SARCOIDOSIS Cytogenetic Profiling In Paediatric Acute Leukaemia; A Report On 746 Newly Diagnosed Paediatric Cases Analyzing The Spectrum Of Recurring Chromosomal Rearrangements In B Cell Lymphoblastic And Acute Myeloid Leukaemia. Risk Loci For Chronic Obstructive Disease Reside On Chromosome 14: A Case-Control Study On The Pakistani Population. Giant Penoscrotal Lymphedema: Planning And Surgical Technique To Treat A Rare Debilitating Disease. Management And Assessment Of Indeterminate (U3) Thyroid Nodules: A 5-Year Multisite Retrospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1