Wang Jie Xu, Ya Jun Pan, Wei Jie Li, Li Na Peng, Dong Li Liang, Man Zhang, Wei Ding, Zhao Xia Wang
{"title":"单管多重巢式PCR系统高效检测SPF级啮齿动物病原微生物。","authors":"Wang Jie Xu, Ya Jun Pan, Wei Jie Li, Li Na Peng, Dong Li Liang, Man Zhang, Wei Ding, Zhao Xia Wang","doi":"10.30802/AALAS-JAALAS-21-000117","DOIUrl":null,"url":null,"abstract":"<p><p>PCR testing is increasingly important for microbial control in SPF facilities. However, most current PCR methods are timeconsuming and require compromise between high sensitivity and high multiplexing. We developed a one-tube multiplex nested PCR strategy (MN-PCR) for simultaneous direct (that is, without culturing) detection of multiple pathogens. We first aligned sequences for the 16S rDNA genes of selected target bacteria and a panel of closely related organisms. From these data, we designed a pair of universal primers and multiple sets of species-specific PCR primers to amplify the target sequences; the universal primers were modified to include various degenerate bases and locked nucleic acids. In a single tube, 16S rDNA sequences were amplified by using the nested PCR primers under high temperature (that is, above 65°C) during the first stage of the MN-PCR procedure, when the target-species-specific PCR primers do not support amplification due to their short length. In addition, the concentration of the nested PCR primers during the first stage was adjusted to ensure that they were consumed and did not yield visible bands themselves. During the second stage, the enriched 16S rDNA sequences then served as templates for amplification of the species-specific fragments by using the multiple PCR primers at low annealing temperatures (that is, below 60°C). The results showed that our MN-PCR method detected as little as 1 fg of target bacterial DNA in a 20-μL reaction volume, whereas conventional multiplex PCR detected a minimum of 1 pg only. Compared with traditional multiplex PCR assays, our MN-PCR system is an effective and efficient culture-free process.</p>","PeriodicalId":50019,"journal":{"name":"Journal of the American Association for Laboratory Animal Science","volume":"61 5","pages":"441-447"},"PeriodicalIF":1.2000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536825/pdf/jaalas2022000441.pdf","citationCount":"1","resultStr":"{\"title\":\"Single-tube Multiplex Nested PCR System for Efficient Detection of Pathogenic Microorganisms in SPF Rodents.\",\"authors\":\"Wang Jie Xu, Ya Jun Pan, Wei Jie Li, Li Na Peng, Dong Li Liang, Man Zhang, Wei Ding, Zhao Xia Wang\",\"doi\":\"10.30802/AALAS-JAALAS-21-000117\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>PCR testing is increasingly important for microbial control in SPF facilities. However, most current PCR methods are timeconsuming and require compromise between high sensitivity and high multiplexing. We developed a one-tube multiplex nested PCR strategy (MN-PCR) for simultaneous direct (that is, without culturing) detection of multiple pathogens. We first aligned sequences for the 16S rDNA genes of selected target bacteria and a panel of closely related organisms. From these data, we designed a pair of universal primers and multiple sets of species-specific PCR primers to amplify the target sequences; the universal primers were modified to include various degenerate bases and locked nucleic acids. In a single tube, 16S rDNA sequences were amplified by using the nested PCR primers under high temperature (that is, above 65°C) during the first stage of the MN-PCR procedure, when the target-species-specific PCR primers do not support amplification due to their short length. In addition, the concentration of the nested PCR primers during the first stage was adjusted to ensure that they were consumed and did not yield visible bands themselves. During the second stage, the enriched 16S rDNA sequences then served as templates for amplification of the species-specific fragments by using the multiple PCR primers at low annealing temperatures (that is, below 60°C). The results showed that our MN-PCR method detected as little as 1 fg of target bacterial DNA in a 20-μL reaction volume, whereas conventional multiplex PCR detected a minimum of 1 pg only. Compared with traditional multiplex PCR assays, our MN-PCR system is an effective and efficient culture-free process.</p>\",\"PeriodicalId\":50019,\"journal\":{\"name\":\"Journal of the American Association for Laboratory Animal Science\",\"volume\":\"61 5\",\"pages\":\"441-447\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536825/pdf/jaalas2022000441.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Association for Laboratory Animal Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.30802/AALAS-JAALAS-21-000117\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Association for Laboratory Animal Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.30802/AALAS-JAALAS-21-000117","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Single-tube Multiplex Nested PCR System for Efficient Detection of Pathogenic Microorganisms in SPF Rodents.
PCR testing is increasingly important for microbial control in SPF facilities. However, most current PCR methods are timeconsuming and require compromise between high sensitivity and high multiplexing. We developed a one-tube multiplex nested PCR strategy (MN-PCR) for simultaneous direct (that is, without culturing) detection of multiple pathogens. We first aligned sequences for the 16S rDNA genes of selected target bacteria and a panel of closely related organisms. From these data, we designed a pair of universal primers and multiple sets of species-specific PCR primers to amplify the target sequences; the universal primers were modified to include various degenerate bases and locked nucleic acids. In a single tube, 16S rDNA sequences were amplified by using the nested PCR primers under high temperature (that is, above 65°C) during the first stage of the MN-PCR procedure, when the target-species-specific PCR primers do not support amplification due to their short length. In addition, the concentration of the nested PCR primers during the first stage was adjusted to ensure that they were consumed and did not yield visible bands themselves. During the second stage, the enriched 16S rDNA sequences then served as templates for amplification of the species-specific fragments by using the multiple PCR primers at low annealing temperatures (that is, below 60°C). The results showed that our MN-PCR method detected as little as 1 fg of target bacterial DNA in a 20-μL reaction volume, whereas conventional multiplex PCR detected a minimum of 1 pg only. Compared with traditional multiplex PCR assays, our MN-PCR system is an effective and efficient culture-free process.
期刊介绍:
The Journal of the American Association for Laboratory Animal Science (JAALAS) serves as an official communication vehicle for the American Association for Laboratory Animal Science (AALAS). The journal includes a section of refereed articles and a section of AALAS association news.
All signed articles, including refereed articles and book reviews, editorials, committee reports, and news and commentary, reflect the individual views of the authors and are not official views of AALAS. The mission of the refereed section of the journal is to disseminate high-quality, peer-reviewed information on animal biology, technology, facility operations, management, and compliance as relevant to the AALAS membership. JAALAS accepts research reports (data-based) or scholarly reports (literature-based), with the caveat that all articles, including solicited manuscripts, must include appropriate references and must undergo peer review.