支气管内超声引导下纵隔淋巴结冷冻活检,用于现场快速评估不确诊/不充分的患者:诊断算法的新步骤。

Venkata N Maturu, Virender P Prasad, Chetan R Vaddepally, Raghotham R Dommata, Shweta Sethi
{"title":"支气管内超声引导下纵隔淋巴结冷冻活检,用于现场快速评估不确诊/不充分的患者:诊断算法的新步骤。","authors":"Venkata N Maturu, Virender P Prasad, Chetan R Vaddepally, Raghotham R Dommata, Shweta Sethi","doi":"10.1097/LBR.0000000000000913","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is considered the investigation of choice for sampling mediastinal nodes. A major drawback of EBUS-TBNA is its lower diagnostic yield for lymphoma and benign diseases. EBUS-guided mediastinal cryobiopsy (EBUS-MCB) is a novel technique that provides larger nodal biopsy samples, with an acceptable safety profile. In this study, we aimed to evaluate the diagnostic yield of EBUS-MCB in patients with an inconclusive rapid on-site evaluation (ROSE).</p><p><strong>Methods: </strong>This is a prospective study of patients who underwent EBUS-TBNA for undiagnosed mediastinal lymphadenopathy. Patients in whom ROSE did not yield a diagnosis (nondiagnostic ROSE) or ROSE revealed scanty atypical cells (inadequate ROSE) were subjected to EBUS-MCB. The diagnostic yield, adequacy, and complications of EBUS-MCB were analyzed.</p><p><strong>Results: </strong>Of the 196 patients undergoing EBUS-TBNA, 46 patients underwent EBUS-MCB. Thirty-two cases underwent EBUS-MCB for a nondiagnostic ROSE. EBUS-MCB confirmed the diagnosis in 19/32 (59.3%) cases. The additive diagnostic yield of EBUS-MCB over EBUS-TBNA was 43.7% (14/32 cases). In all 14 cases where EBUS-MCB was performed for an inadequate ROSE, the material obtained by EBUS-MCB was adequate for ancillary studies. The most common complication observed was a minor bleed in 13 cases.</p><p><strong>Conclusion: </strong>EBUS-MCB has a diagnostic yield of 59.3% when performed in cases with a nondiagnostic EBUS-ROSE. The tissue obtained by EBUS-MCB is adequate for ancillary studies. We propose EBUS-MCB as an additional diagnostic step in cases with an inconclusive ROSE while performing EBUS-TBNA. Larger studies are, however, needed before EBUS-MCB can be incorporated in the diagnostic algorithm for the evaluation of mediastinal lesions.</p>","PeriodicalId":15268,"journal":{"name":"Journal of Bronchology & Interventional Pulmonology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Endobronchial Ultrasound-guided Mediastinal Lymph Nodal Cryobiopsy in Patients With Nondiagnostic/Inadequate Rapid On-site Evaluation: A New Step in the Diagnostic Algorithm.\",\"authors\":\"Venkata N Maturu, Virender P Prasad, Chetan R Vaddepally, Raghotham R Dommata, Shweta Sethi\",\"doi\":\"10.1097/LBR.0000000000000913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is considered the investigation of choice for sampling mediastinal nodes. A major drawback of EBUS-TBNA is its lower diagnostic yield for lymphoma and benign diseases. EBUS-guided mediastinal cryobiopsy (EBUS-MCB) is a novel technique that provides larger nodal biopsy samples, with an acceptable safety profile. In this study, we aimed to evaluate the diagnostic yield of EBUS-MCB in patients with an inconclusive rapid on-site evaluation (ROSE).</p><p><strong>Methods: </strong>This is a prospective study of patients who underwent EBUS-TBNA for undiagnosed mediastinal lymphadenopathy. Patients in whom ROSE did not yield a diagnosis (nondiagnostic ROSE) or ROSE revealed scanty atypical cells (inadequate ROSE) were subjected to EBUS-MCB. The diagnostic yield, adequacy, and complications of EBUS-MCB were analyzed.</p><p><strong>Results: </strong>Of the 196 patients undergoing EBUS-TBNA, 46 patients underwent EBUS-MCB. Thirty-two cases underwent EBUS-MCB for a nondiagnostic ROSE. EBUS-MCB confirmed the diagnosis in 19/32 (59.3%) cases. The additive diagnostic yield of EBUS-MCB over EBUS-TBNA was 43.7% (14/32 cases). In all 14 cases where EBUS-MCB was performed for an inadequate ROSE, the material obtained by EBUS-MCB was adequate for ancillary studies. The most common complication observed was a minor bleed in 13 cases.</p><p><strong>Conclusion: </strong>EBUS-MCB has a diagnostic yield of 59.3% when performed in cases with a nondiagnostic EBUS-ROSE. The tissue obtained by EBUS-MCB is adequate for ancillary studies. We propose EBUS-MCB as an additional diagnostic step in cases with an inconclusive ROSE while performing EBUS-TBNA. Larger studies are, however, needed before EBUS-MCB can be incorporated in the diagnostic algorithm for the evaluation of mediastinal lesions.</p>\",\"PeriodicalId\":15268,\"journal\":{\"name\":\"Journal of Bronchology & Interventional Pulmonology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Bronchology & Interventional Pulmonology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/LBR.0000000000000913\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bronchology & Interventional Pulmonology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/LBR.0000000000000913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

背景:支气管内超声引导下经支气管针吸术(EBUS-TBNA)被认为是纵隔结节取样的首选检查方法。EBUS-TBNA 的主要缺点是对淋巴瘤和良性疾病的诊断率较低。EBUS 导向纵隔冷冻活检(EBUS-MCB)是一种新型技术,可提供更大的结节活检样本,且安全性可接受。在这项研究中,我们旨在评估 EBUS-MCB 对快速现场评估(ROSE)未得出结论的患者的诊断率:这是一项前瞻性研究,研究对象是因纵隔淋巴结病未确诊而接受 EBUS-TBNA 检查的患者。ROSE未得出诊断结果(无诊断性ROSE)或ROSE显示非典型细胞稀少(ROSE不足)的患者接受了EBUS-MCB检查。对 EBUS-MCB 的诊断率、充分性和并发症进行了分析:在接受 EBUS-TBNA 检查的 196 例患者中,有 46 例接受了 EBUS-MCB。32例患者因无法诊断ROSE而接受了EBUS-MCB。19/32(59.3%)例患者通过 EBUS-MCB 确诊。与 EBUS-TBNA 相比,EBUS-MCB 的附加诊断率为 43.7%(14/32 例)。在所有 14 例因 ROSE 不足而进行 EBUS-MCB 的病例中,EBUS-MCB 获得的材料足以进行辅助检查。最常见的并发症是13例轻微出血:结论:在 EBUS-ROSE 无法确诊的病例中,EBUS-MCB 的诊断率为 59.3%。通过 EBUS-MCB 获得的组织足以进行辅助检查。我们建议在进行 EBUS-TBNA 时将 EBUS-MCB 作为 ROSE 未确诊病例的额外诊断步骤。不过,在将 EBUS-MCB 纳入纵隔病变评估的诊断算法之前,还需要进行更大规模的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Endobronchial Ultrasound-guided Mediastinal Lymph Nodal Cryobiopsy in Patients With Nondiagnostic/Inadequate Rapid On-site Evaluation: A New Step in the Diagnostic Algorithm.

Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is considered the investigation of choice for sampling mediastinal nodes. A major drawback of EBUS-TBNA is its lower diagnostic yield for lymphoma and benign diseases. EBUS-guided mediastinal cryobiopsy (EBUS-MCB) is a novel technique that provides larger nodal biopsy samples, with an acceptable safety profile. In this study, we aimed to evaluate the diagnostic yield of EBUS-MCB in patients with an inconclusive rapid on-site evaluation (ROSE).

Methods: This is a prospective study of patients who underwent EBUS-TBNA for undiagnosed mediastinal lymphadenopathy. Patients in whom ROSE did not yield a diagnosis (nondiagnostic ROSE) or ROSE revealed scanty atypical cells (inadequate ROSE) were subjected to EBUS-MCB. The diagnostic yield, adequacy, and complications of EBUS-MCB were analyzed.

Results: Of the 196 patients undergoing EBUS-TBNA, 46 patients underwent EBUS-MCB. Thirty-two cases underwent EBUS-MCB for a nondiagnostic ROSE. EBUS-MCB confirmed the diagnosis in 19/32 (59.3%) cases. The additive diagnostic yield of EBUS-MCB over EBUS-TBNA was 43.7% (14/32 cases). In all 14 cases where EBUS-MCB was performed for an inadequate ROSE, the material obtained by EBUS-MCB was adequate for ancillary studies. The most common complication observed was a minor bleed in 13 cases.

Conclusion: EBUS-MCB has a diagnostic yield of 59.3% when performed in cases with a nondiagnostic EBUS-ROSE. The tissue obtained by EBUS-MCB is adequate for ancillary studies. We propose EBUS-MCB as an additional diagnostic step in cases with an inconclusive ROSE while performing EBUS-TBNA. Larger studies are, however, needed before EBUS-MCB can be incorporated in the diagnostic algorithm for the evaluation of mediastinal lesions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
6.10%
发文量
121
期刊最新文献
Ibrutinib and Bleeding Hazards During Bronchoscopy. Rapid Pleurodesis in Patients With Chronic Noninfectious Pleural Effusion: Twenty Years of Real-world Performance Data. Safety and Efficacy of Rigid Bronchoscopy-guided Percutaneous Dilational Tracheostomy: A Single-center Experience. Diagnostic Value and Safety of Addition of Transbronchial Needle Aspiration to Transbronchial Biopsy Through Endobronchial Ultrasonography Using a Guide Sheath Under Virtual Bronchoscopic Navigation for the Diagnosis of Peripheral Pulmonary Lesions. Percutaneous Airway Silicone Stent External Fixation Outcomes and Techniques: Case Series With Literature Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1