胎盘功能不全致生长受限胎儿的胸腺。

IF 1.2 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL Revista da Associacao Medica Brasileira Pub Date : 2023-01-01 DOI:10.1590/1806-9282.20220975
Marisa Akemi Takeno, Roseli Mieko Yamamoto Nomura
{"title":"胎盘功能不全致生长受限胎儿的胸腺。","authors":"Marisa Akemi Takeno,&nbsp;Roseli Mieko Yamamoto Nomura","doi":"10.1590/1806-9282.20220975","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to assess fetal thymus size by ultrasound in growth-restricted fetuses due to placental insufficiency and compare to high-risk and low-risk pregnancy fetuses with normal placental function.</p><p><strong>Methods: </strong>This is a nested case-control study of pregnant women followed up at a university hospital (July 2012 to July 2013). In all, 30 pregnant women presenting small fetuses for gestational age (estimated fetal weight <p10) due to placental insufficiency (umbilical artery Doppler >p95) were compared to 30 high-risk and 30 low-risk pregnancies presenting normal Doppler indices. The thymus transverse diameter and perimeter were converted into zeta score according to the normal values for gestational age. Head circumference and femur length were used to calculate ratios.</p><p><strong>Results: </strong>Fetal thymus were significantly lower in pregnancies with placental insufficiency when compared to high-risk and low-risk pregnancies presenting, respectively, transverse diameter zeta score (-0.69±0.83 vs. 0.49±1.13 vs. 0.83±0.85, p<0.001) and P zeta score (-0.73±0.68 vs. 0.45±0.96 vs. 0.26±0.89, p<0.001). There was also a significant difference (p<0.05) in the ratios among the groups: pregnancies with placental insufficiency (TD/HC=0.10, P/FL=1.32, and P/HC=0.26), high-risk pregnancies (TD/HC=0.11, P/FL=1.40, and P/HC=0.30), and control group (DT/HC=0.11, P/FL=1.45, and P/HC=0.31).</p><p><strong>Conclusion: </strong>Fetal thymus size is reduced in growth-restricted fetuses due to placental insufficiency, suggesting fetal response as a consequence of the adverse environment.</p>","PeriodicalId":21234,"journal":{"name":"Revista da Associacao Medica Brasileira","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/17/8e/1806-9282-ramb-69-01-0136.PMC9937593.pdf","citationCount":"0","resultStr":"{\"title\":\"Fetal thymus in growth-restricted fetuses due to placental insufficiency.\",\"authors\":\"Marisa Akemi Takeno,&nbsp;Roseli Mieko Yamamoto Nomura\",\"doi\":\"10.1590/1806-9282.20220975\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of this study was to assess fetal thymus size by ultrasound in growth-restricted fetuses due to placental insufficiency and compare to high-risk and low-risk pregnancy fetuses with normal placental function.</p><p><strong>Methods: </strong>This is a nested case-control study of pregnant women followed up at a university hospital (July 2012 to July 2013). In all, 30 pregnant women presenting small fetuses for gestational age (estimated fetal weight <p10) due to placental insufficiency (umbilical artery Doppler >p95) were compared to 30 high-risk and 30 low-risk pregnancies presenting normal Doppler indices. The thymus transverse diameter and perimeter were converted into zeta score according to the normal values for gestational age. Head circumference and femur length were used to calculate ratios.</p><p><strong>Results: </strong>Fetal thymus were significantly lower in pregnancies with placental insufficiency when compared to high-risk and low-risk pregnancies presenting, respectively, transverse diameter zeta score (-0.69±0.83 vs. 0.49±1.13 vs. 0.83±0.85, p<0.001) and P zeta score (-0.73±0.68 vs. 0.45±0.96 vs. 0.26±0.89, p<0.001). There was also a significant difference (p<0.05) in the ratios among the groups: pregnancies with placental insufficiency (TD/HC=0.10, P/FL=1.32, and P/HC=0.26), high-risk pregnancies (TD/HC=0.11, P/FL=1.40, and P/HC=0.30), and control group (DT/HC=0.11, P/FL=1.45, and P/HC=0.31).</p><p><strong>Conclusion: </strong>Fetal thymus size is reduced in growth-restricted fetuses due to placental insufficiency, suggesting fetal response as a consequence of the adverse environment.</p>\",\"PeriodicalId\":21234,\"journal\":{\"name\":\"Revista da Associacao Medica Brasileira\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/17/8e/1806-9282-ramb-69-01-0136.PMC9937593.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista da Associacao Medica Brasileira\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1806-9282.20220975\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista da Associacao Medica Brasileira","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1806-9282.20220975","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过超声评估胎盘功能不全致生长受限胎儿胸腺大小,并与胎盘功能正常的高危和低危妊娠胎儿进行比较。方法:采用巢式病例对照研究,对2012年7月至2013年7月在某大学医院随访的孕妇进行随访。总的来说,30名胎龄较小的孕妇(估计胎儿体重p95)与30名多普勒指数正常的高危孕妇和30名低危孕妇进行了比较。按胎龄正常值将胸腺横径和胸腺周长换算成zeta评分。用头围和股骨长度计算比值。结果:胎盘功能不全妊娠的胎儿胸腺明显小于高危妊娠和低危妊娠,其横径zeta评分分别为(-0.69±0.83 vs. 0.49±1.13 vs. 0.83±0.85)。结论:胎盘功能不全导致生长受限胎儿胸腺大小减小,提示胎儿反应是不良环境的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fetal thymus in growth-restricted fetuses due to placental insufficiency.

Objective: The aim of this study was to assess fetal thymus size by ultrasound in growth-restricted fetuses due to placental insufficiency and compare to high-risk and low-risk pregnancy fetuses with normal placental function.

Methods: This is a nested case-control study of pregnant women followed up at a university hospital (July 2012 to July 2013). In all, 30 pregnant women presenting small fetuses for gestational age (estimated fetal weight p95) were compared to 30 high-risk and 30 low-risk pregnancies presenting normal Doppler indices. The thymus transverse diameter and perimeter were converted into zeta score according to the normal values for gestational age. Head circumference and femur length were used to calculate ratios.

Results: Fetal thymus were significantly lower in pregnancies with placental insufficiency when compared to high-risk and low-risk pregnancies presenting, respectively, transverse diameter zeta score (-0.69±0.83 vs. 0.49±1.13 vs. 0.83±0.85, p<0.001) and P zeta score (-0.73±0.68 vs. 0.45±0.96 vs. 0.26±0.89, p<0.001). There was also a significant difference (p<0.05) in the ratios among the groups: pregnancies with placental insufficiency (TD/HC=0.10, P/FL=1.32, and P/HC=0.26), high-risk pregnancies (TD/HC=0.11, P/FL=1.40, and P/HC=0.30), and control group (DT/HC=0.11, P/FL=1.45, and P/HC=0.31).

Conclusion: Fetal thymus size is reduced in growth-restricted fetuses due to placental insufficiency, suggesting fetal response as a consequence of the adverse environment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
0.00%
发文量
276
审稿时长
12 weeks
期刊介绍: A Revista da Associação Médica Brasileira (RAMB), editada pela Associação Médica Brasileira, desde 1954, tem por objetivo publicar artigos que contribuam para o conhecimento médico.
期刊最新文献
Anatomical features of sella turcica with comprehensive literature review. ERRATUM. A needful, unique, and in-place evaluation of the injuries in earthquake victims with computed tomography, in catastrophic disasters! The 2023 Turkey-Syria earthquakes: part II. The challenge of tobacco and nicotine use among women. 18F-fluoroestradiol positron emission tomography in patients with breast cancer: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1