在复杂主动脉重建过程中,成功通过血管内抢救部署不当的髂骨肢体延伸。

IF 1 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE Vascular Pub Date : 2024-08-01 Epub Date: 2023-03-08 DOI:10.1177/17085381231156668
Ryan Gedney, Adam Tanious, Mathew Wooster
{"title":"在复杂主动脉重建过程中,成功通过血管内抢救部署不当的髂骨肢体延伸。","authors":"Ryan Gedney, Adam Tanious, Mathew Wooster","doi":"10.1177/17085381231156668","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The worst complication during cannulation of the contralateral gate during complex endovascular aortic repair is deployment of the limb extension behind the main graft body.</p><p><strong>Case report: </strong>A patient with a 5.7 cm juxtarenal abdominal aortic aneurysm was taken to the operating room for fenestrated endovascular aortic repair and iliac branch device. Percutaneous femoral access was used to deploy a Gore Iliac Branch Endoprosthesis, followed by a physician modified Cook Alpha thoracic stent graft with four fenestrations. Next a Gore Excluder was deployed to bridge the fenestrated component to the iliac branch and native left common iliac artery creating distal seal. Due to the severe tortuosity, a buddy wire technique, using a stiff lunderquist wire, was used to cannulate the contralateral gate. Unfortunately, after cannulation, the limb was advanced over the buddy lunderquist wire instead of the luminal wire. We used a backtable modified guide catheter to provide the necessary pushability to navigate wires between the aberrantly deployed limb extension and the iliac branch device. Using through-and-through access, we then successfully deployed a parallel flared limb in the correct plane.</p><p><strong>Conclusion: </strong>Careful communication, wire marking, and attention to intraoperative flow can minimize risks of complication, but knowledge of bail out techniques remains imperative.</p>","PeriodicalId":23549,"journal":{"name":"Vascular","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Successful endovascular salvage of a maldeployed iliac limb extension during complex aortic reconstruction.\",\"authors\":\"Ryan Gedney, Adam Tanious, Mathew Wooster\",\"doi\":\"10.1177/17085381231156668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The worst complication during cannulation of the contralateral gate during complex endovascular aortic repair is deployment of the limb extension behind the main graft body.</p><p><strong>Case report: </strong>A patient with a 5.7 cm juxtarenal abdominal aortic aneurysm was taken to the operating room for fenestrated endovascular aortic repair and iliac branch device. Percutaneous femoral access was used to deploy a Gore Iliac Branch Endoprosthesis, followed by a physician modified Cook Alpha thoracic stent graft with four fenestrations. Next a Gore Excluder was deployed to bridge the fenestrated component to the iliac branch and native left common iliac artery creating distal seal. Due to the severe tortuosity, a buddy wire technique, using a stiff lunderquist wire, was used to cannulate the contralateral gate. Unfortunately, after cannulation, the limb was advanced over the buddy lunderquist wire instead of the luminal wire. We used a backtable modified guide catheter to provide the necessary pushability to navigate wires between the aberrantly deployed limb extension and the iliac branch device. Using through-and-through access, we then successfully deployed a parallel flared limb in the correct plane.</p><p><strong>Conclusion: </strong>Careful communication, wire marking, and attention to intraoperative flow can minimize risks of complication, but knowledge of bail out techniques remains imperative.</p>\",\"PeriodicalId\":23549,\"journal\":{\"name\":\"Vascular\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vascular\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17085381231156668\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17085381231156668","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/8 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的:在复杂的血管内主动脉修补术中,对侧门插管时最严重的并发症是在主移植物体后面部署肢体延伸部分:病例报告:一名患有 5.7 厘米并arenal 腹主动脉瘤的患者被送入手术室,接受开窗式血管内主动脉修补术和髂支装置。手术使用经皮股动脉入路部署了戈尔髂支假体,然后是经医生改良的库克阿尔法胸腔支架移植物,有四个开孔。接着,部署了戈尔排除器,将开孔组件与髂支和原生左髂总动脉连接起来,形成远端密封。由于迂曲严重,使用坚硬的 Lunderquist 钢丝进行对侧闸门插管。不幸的是,插管后,肢体被推进到结伴鲁德奎斯特导丝上,而不是管腔导丝上。我们使用了后台式改良导引导管,以提供必要的推动力,在异常展开的肢体延伸部分和髂支装置之间引导导线。然后,我们使用穿透式入路,成功地在正确的平面上部署了平行外展的肢体:结论:谨慎的沟通、导线标记以及对术中血流的关注可将并发症风险降至最低,但掌握保外技术仍是当务之急。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Successful endovascular salvage of a maldeployed iliac limb extension during complex aortic reconstruction.

Purpose: The worst complication during cannulation of the contralateral gate during complex endovascular aortic repair is deployment of the limb extension behind the main graft body.

Case report: A patient with a 5.7 cm juxtarenal abdominal aortic aneurysm was taken to the operating room for fenestrated endovascular aortic repair and iliac branch device. Percutaneous femoral access was used to deploy a Gore Iliac Branch Endoprosthesis, followed by a physician modified Cook Alpha thoracic stent graft with four fenestrations. Next a Gore Excluder was deployed to bridge the fenestrated component to the iliac branch and native left common iliac artery creating distal seal. Due to the severe tortuosity, a buddy wire technique, using a stiff lunderquist wire, was used to cannulate the contralateral gate. Unfortunately, after cannulation, the limb was advanced over the buddy lunderquist wire instead of the luminal wire. We used a backtable modified guide catheter to provide the necessary pushability to navigate wires between the aberrantly deployed limb extension and the iliac branch device. Using through-and-through access, we then successfully deployed a parallel flared limb in the correct plane.

Conclusion: Careful communication, wire marking, and attention to intraoperative flow can minimize risks of complication, but knowledge of bail out techniques remains imperative.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vascular
Vascular 医学-外周血管病
CiteScore
2.30
自引率
9.10%
发文量
196
审稿时长
6-12 weeks
期刊介绍: Vascular provides readers with new and unusual up-to-date articles and case reports focusing on vascular and endovascular topics. It is a highly international forum for the discussion and debate of all aspects of this distinct surgical specialty. It also features opinion pieces, literature reviews and controversial issues presented from various points of view.
期刊最新文献
Comparative outcomes of surgical and conservative management in carotid artery dissection. Physician-modified funnel-shaped covered stent for selective false lumen exclusion in chronic type B aortic dissection. Embolization of a ruptured cystic artery pseudoaneurysm by percutaneous injection. A systematic review and meta-analysis of outcomes associated with development of surgical site infection after lower-limb revascularization surgery. Malnutrition is associated with adverse 30-day outcomes after endovascular repair of abdominal aortic aneurysm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1